Automatic measurement of the labyrinth using image registration and a deformable inner ear atlas.

RATIONALE AND OBJECTIVES This article presents a new method for measuring the shape of the cochlea, vestibule, semi-circular canals, and internal auditory canal using image registration and a deformable inner ear atlas. MATERIALS AND METHODS Computed tomography images of the inner ear are analyzed by placing them into a common orientation and then registering a digital atlas of the inner ear to the data set. The atlas is deformed from its original shape to match the shape of the inner ear in the computed tomography data set using inverse consistent elastic image registration. This process produces an individualized inner ear atlas containing subject-specific measurements and segmentations of the inner ear anatomy in the target computed tomography data set. The shape measurements include the volume and length of the cochlea, vestibule, semi-circular canals, and internal auditory canal; and the angles between the semi-circular canals. RESULTS A simulated population of inner ear shapes were generated based on the shape of a real population of inner ear shapes and were used to characterize the measurement error of this method. The deformable atlas was used to measure the shape of the left and right inner ear of six individuals. CONCLUSION Measurement error for 15 of the 24 measurements of our simulated population had an average error of less than 1% and only one measurement had an average error greater than 2.54%. The deformable human inner ear atlas shows promise as a new method for automatically measuring the shape of the labyrinth.

[1]  W. Kalender,et al.  Determination of the position of nucleus cochlear implant electrodes in the inner ear. , 1994, The American journal of otology.

[2]  A. J. Grant,et al.  Comparison of three-dimensional visualization techniques for depicting the scala vestibuli and scala tympani of the cochlea by using high-resolution MR imaging. , 1999, AJNR. American journal of neuroradiology.

[3]  Ge Wang,et al.  Three-dimensional geometric modeling of the cochlea using helico-spiral approximation , 2000, IEEE Trans. Biomed. Eng..

[4]  Gary E. Christensen,et al.  Consistent landmark and intensity-based image registration , 2002, IEEE Transactions on Medical Imaging.

[5]  D Caramella,et al.  Virtual endoscopy of the middle and inner ear with spiral computed tomography. , 2000, American Journal of Otology.

[6]  Y Tamakawa,et al.  Virtual CT endoscopy of ossicles in the middle ear. , 2001, Clinical imaging.

[7]  Ayse Aralasmak,et al.  Magnetic resonance imaging versus computed tomography in pre-operative evaluation of cochlear implant candidates with congenital hearing loss , 2002, The Journal of Laryngology & Otology.

[8]  W.A. Kalender,et al.  Unwrapping cochlear implants by spiral CT , 1996, IEEE Transactions on Biomedical Engineering.

[9]  Walter D. Glanze Mosby's Medical, Nursing, and Allied Health Dictionary , 1993 .

[10]  Graeme M. Clark,et al.  Computer-Aided Three-Dimensional Reconstruction in Human Cochlear Maps: Measurement of the Lengths of Organ of Corti, Outer Wall, Inner Wall, and Rosenthal's Canal , 1996, The Annals of otology, rhinology, and laryngology.

[11]  M. Völk,et al.  Value of high-resolution MR in patients scheduled for cochlear implantation. , 2001, Acta radiologica.

[12]  Stanley Jablonski,et al.  Illustrated dictionary of dentistry , 1982 .

[13]  H. C. Davidson,et al.  Preoperative cochlear implant imaging: is magnetic resonance imaging enough? , 2000, The American journal of otology.

[14]  K Murata,et al.  Three-dimensional magnetic resonance imaging findings of inner ear anomaly. , 2000, Acta oto-laryngologica. Supplementum.

[15]  R A Robb,et al.  Three‐dimensional reconstruction of the temporal bone , 1990, The Laryngoscope.

[16]  Ivo P. Janecka,et al.  Three-Dimensional Computer Reconstruction of a Temporal Bone , 1989 .

[17]  F A Spelman,et al.  Three-dimensional reconstruction of the cochlea from two-dimensional images of optical sections. , 1995, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[18]  Gary E. Christensen,et al.  Consistent image registration , 2001, IEEE Transactions on Medical Imaging.

[19]  Isamu Sando,et al.  Computer-Aided Three-Dimensional Reconstruction: A Method of Measuring Temporal Bone Structures Including the Length of the Cochlea , 1989, The Annals of otology, rhinology, and laryngology.

[20]  Jeroen J Briaire,et al.  Field patterns in a 3D tapered spiral model of the electrically stimulated cochlea , 2000, Hearing Research.

[21]  M. Torrens Co-Planar Stereotaxic Atlas of the Human Brain—3-Dimensional Proportional System: An Approach to Cerebral Imaging, J. Talairach, P. Tournoux. Georg Thieme Verlag, New York (1988), 122 pp., 130 figs. DM 268 , 1990 .

[22]  G. Wang,et al.  In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. , 1998, The Annals of otology, rhinology & laryngology. Supplement.