Chemometric analysis of complex hyphenated data. Improvements of the component detection algorithm.

Component detection algorithm (CODA) is a method to quickly extract the high-quality mass chromatograms from complex liquid chromatography/electrospray ionization mass spectrometry (LC/MS) data sets, saving operators hours of analysis time. It appeared, however, that mass chromatograms with a limited baseline problem were ignored. This paper describes several methods to increase the tolerance for mass chromatograms with a baseline.

[1]  J. Henion,et al.  Comparison between liquid chromatography-UV detection and liquid chromatography-mass spectrometry for the characterization of impurities and/or degradants present in trimethoprim tablets. , 2002, Journal of chromatography. A.

[2]  Melissa D. Krebs,et al.  Autoregressive modeling of analytical sensor data can yield classifiers in the predictor coefficient parameter space , 2005, Bioinform..

[3]  W. Windig,et al.  A Noise and Background Reduction Method for Component Detection in Liquid Chromatography/Mass Spectrometry , 1996 .

[4]  Bruce R. Kowalski,et al.  Windowed mass selection method: a new data processing algorithm for liquid chromatography–mass spectrometry data , 1999 .

[5]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[6]  Gordon A. Anderson,et al.  Application of sequential paired covariance to liquid chromatography-mass spectrometry data enhancements in both the signal-to-noise ratio and the resolution of analyte peaks in the chromatogram , 1997 .

[7]  Alan L. Rockwood,et al.  Application of sequential paired covariance to capillary electrophoresis electrospray ionization time-of-flight mass spectrometry: Unraveling the signal from the noise in the electropherogram , 1995 .

[8]  R. Jansen,et al.  Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis. , 2006, Journal of chromatography. A.

[9]  Willem Windig,et al.  Fast interpretation of complex LC/MS data using chemometrics , 2001 .

[10]  R. Brereton,et al.  Component detection weighted index of analogy: similarity recognition on liquid chromatographic mass spectral data for the characterization of route/process specific impurities in pharmaceutical tablets. , 2005, Analytical Chemistry.

[11]  T. Rejtar,et al.  A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain. , 2003, Analytical chemistry.