In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice☆

External beam radiotherapy with photon beams is a highly accurate treatment modality, but requires extensive quality assurance programs to confirm that radiation therapy will be or was administered appropriately. In vivo dosimetry (IVD) is an essential element of modern radiation therapy because it provides the ability to catch treatment delivery errors, assist in treatment adaptation, and record the actual dose delivered to the patient. However, for various reasons, its clinical implementation has been slow and limited. The purpose of this report is to stimulate the wider use of IVD for external beam radiotherapy, and in particular of systems using electronic portal imaging devices (EPIDs). After documenting the current IVD methods, this report provides detailed software, hardware and system requirements for in vivo EPID dosimetry systems in order to help in bridging the current vendor-user gap. The report also outlines directions for further development and research. In vivo EPID dosimetry vendors, in collaboration with users across multiple institutions, are requested to improve the understanding and reduce the uncertainties of the system and to help in the determination of optimal action limits for error detection. Finally, the report recommends that automation of all aspects of IVD is needed to help facilitate clinical adoption, including automation of image acquisition, analysis, result interpretation, and reporting/documentation. With the guidance of this report, it is hoped that widespread clinical use of IVD will be significantly accelerated.

[1]  Peter B Greer,et al.  Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy. , 2003, Medical physics.

[2]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. , 1992, Physics in medicine and biology.

[3]  Jan-Jakob Sonke,et al.  A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments. , 2009, Medical physics.

[4]  A Ruiz,et al.  Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams. , 2004, Medical physics.

[5]  Adam C. Riegel,et al.  Dosimetric impact of placement errors in optically stimulated luminescent in vivo dosimetry in radiotherapy , 2019, Physics and imaging in radiation oncology.

[6]  Marcel van Herk,et al.  Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry. , 2015, Practical radiation oncology.

[7]  N. Jornet,et al.  Thermoluminescence dosimetry applied to in vivo dose measurements for total body irradiation techniques. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  T. Nyholm,et al.  A practical approach to diode based in vivo dosimetry for intensity modulated radiotherapy. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  D. Kuban,et al.  Toward a real-time in vivo dosimetry system using plastic scintillation detectors. , 2010, International journal of radiation oncology, biology, physics.

[10]  P. François,et al.  EPID based in vivo dosimetry system: clinical experience and results , 2016, Journal of applied clinical medical physics.

[11]  J. Kim,et al.  A Monte Carlo calculation model of electronic portal imaging device for transit dosimetry through heterogeneous media. , 2016, Medical physics.

[12]  Savino Cilla,et al.  Routine EPID in-vivo dosimetry in a reference point for conformal radiotherapy treatments. , 2015, Physics in medicine and biology.

[13]  Ben Mijnheer,et al.  Site‐specific alert criteria to detect patient‐related errors with 3D EPID transit dosimetry , 2018, Medical physics.

[14]  P. Jursinic,et al.  In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material. , 2011, Medical physics.

[15]  Indra J. Das,et al.  Radiochromic Film: Role and Applications in Radiation Dosimetry , 2017 .

[16]  Audrey H. Zhuang,et al.  Sensitivity study of an automated system for daily patient QA using EPID exit dose images , 2018, Journal of applied clinical medical physics.

[17]  Jan-Jakob Sonke,et al.  In aqua vivo EPID dosimetry. , 2011, Medical physics.

[18]  Jean Pouliot,et al.  Investigating the clinical advantages of a robotic linac equipped with a multileaf collimator in the treatment of brain and prostate cancer patients , 2015, Journal of applied clinical medical physics.

[19]  M. Anscher,et al.  Technical evaluation of radiation dose delivered in prostate cancer patients as measured by an implantable MOSFET dosimeter. , 2007, International journal of radiation oncology, biology, physics.

[20]  Marcel van Herk,et al.  Online 3D EPID-based dose verification: Proof of concept. , 2016, Medical physics.

[21]  Michael Kuperberg,et al.  Markov Models , 2019, Earthquake Statistical Analysis through Multi-state Modeling.

[22]  S. Weston,et al.  Feasibility of portal dosimetry for flattening filter‐free radiotherapy , 2016, Journal of applied clinical medical physics.

[23]  Frank Verhaegen,et al.  Time dependent pre-treatment EPID dosimetry for standard and FFF VMAT , 2014, Physics in medicine and biology.

[24]  A. Sawant,et al.  Kilovoltage transit and exit dosimetry for a small animal image‐guided radiotherapy system using built‐in EPID , 2018, Medical physics.

[25]  L. Holloway,et al.  Dose calibration of EPIDs for segmented IMRT dosimetry , 2014, Journal of applied clinical medical physics.

[26]  Ben Mijnheer,et al.  Clinical 3D Dosimetry in Modern Radiation Therapy , 2017 .

[27]  D. Huyskens,et al.  Feasibility study of entrance in vivo dose measurements with mailed thermoluminescence detectors. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  Philippe Lambin,et al.  Total body irradiation, toward optimal individual delivery: dose evaluation with metal oxide field effect transistors, thermoluminescence detectors, and a treatment planning system. , 2007, International journal of radiation oncology, biology, physics.

[29]  B. Mijnheer,et al.  Transit and non‐transit 3D EPID dosimetry versus detector arrays for patient specific QA , 2019, Journal of applied clinical medical physics.

[30]  Savino Cilla,et al.  Application of a practical method for the isocenter point in vivo dosimetry by a transit signal , 2007, Physics in medicine and biology.

[31]  M. Benassi,et al.  Setup verification and in vivo dosimetry during intraoperative radiation therapy (IORT) for prostate cancer. , 2007, Medical physics.

[32]  B. Mijnheer,et al.  The effect of the choice of patient model on the performance of in vivo 3D EPID dosimetry to detect variations in patient position and anatomy. , 2019, Medical physics.

[33]  Ping Xia,et al.  Investigation of the use of MOSFET for clinical IMRT dosimetric verification. , 2002, Medical physics.

[34]  L. Archambault,et al.  Classification of changes occurring in lung patient during radiotherapy using relative γ analysis and hidden Markov models , 2017, Medical physics.

[35]  Sean L Berry,et al.  Initial clinical experience performing patient treatment verification with an electronic portal imaging device transit dosimeter. , 2014, International journal of radiation oncology, biology, physics.

[36]  F Verhaegen,et al.  Time-Resolved Versus Integrated Transit Planar Dosimetry for Volumetric Modulated Arc Therapy , 2016, Technology in cancer research & treatment.

[37]  Peter B Greer,et al.  Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm. , 2015, Medical physics.

[38]  J. Dam,et al.  METHODS FOR IN VIVO DOSIMETRY IN EXTERNAL RADIOTHERAPY , 2005 .

[39]  M. V. van Herk,et al.  Automatic in vivo portal dosimetry of all treatments , 2013, Physics in medicine and biology.

[40]  J. Bourhis,et al.  Dosimetric and preparation procedures for irradiating biological models with pulsed electron beam at ultra-high dose-rate. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[41]  Robert E. Drzymala,et al.  Errors in radiation oncology: A study in pathways and dosimetric impact , 2005, Journal of applied clinical medical physics.

[42]  L. Holloway,et al.  Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy. , 2015, Medical physics.

[43]  O. Morin,et al.  Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software , 2018, Cureus.

[44]  Marco Esposito,et al.  Estimating dose delivery accuracy in stereotactic body radiation therapy: a review of in-vivo measurement methods. , 2020, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[45]  B. Loo,et al.  Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator. , 2017, International journal of radiation oncology, biology, physics.

[46]  A. Morgan,et al.  In vivo dosimetry in UK external beam radiotherapy: current and future usage. , 2017, The British journal of radiology.

[47]  Duncan B. McLaren,et al.  EPID‐based in vivo dosimetry using Dosimetry Check™: Overview and clinical experience in a 5‐yr study including breast, lung, prostate, and head and neck cancer patients , 2018, Journal of applied clinical medical physics.

[48]  Philippe Lambin,et al.  The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations. , 2008, Radiotherapy and Oncology.

[49]  Jan-Jakob Sonke,et al.  3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[50]  J. Bourhis,et al.  Treatment of a first patient with FLASH-radiotherapy. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[51]  Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system. , 2014, Physics in medicine and biology.

[52]  Alejandra Rangel,et al.  ROC analysis in patient specific quality assurance. , 2013, Medical physics.

[53]  M. Gillin,et al.  Implantable MOSFET detectors: evaluation of a new design. , 2007, Medical physics.

[54]  R. Sloboda,et al.  Consequences of the spectral response of an a-Si EPID and implications for dosimetric calibration. , 2005, Medical physics.

[55]  Preliminary investigation of a reusable radiochromic sheet for radiation dosimetry , 2019, Journal of Physics: Conference Series.

[56]  N. Jornet,et al.  Midplane dose determination during total body irradiation using in vivo dosimetry. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[57]  James L Bedford,et al.  Portal dosimetry for VMAT using integrated images obtained during treatment. , 2014, Medical physics.

[58]  R. Kudchadker,et al.  Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer , 2014, Physics in medicine and biology.

[59]  P M McCowan,et al.  A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID , 2017, Physics in medicine and biology.

[60]  James L Bedford,et al.  Comparison of forward- and back-projection in vivo EPID dosimetry for VMAT treatment of the prostate , 2018, Physics in medicine and biology.

[61]  F. Verhaegen,et al.  A novel time dependent gamma evaluation function for dynamic 2D and 3D dose distributions , 2014, Physics in medicine and biology.

[62]  Ben Mijnheer,et al.  In vivo dosimetry in external beam radiotherapy. , 2013, Medical physics.

[63]  Luc Beaulieu,et al.  Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy , 2016, Physics in medicine and biology.

[64]  J. Bedford,et al.  Electronic Portal Imaging Device Dosimetry , 2017 .

[65]  James L. Bedford,et al.  Quality control of VMAT synchronization using portal imaging , 2015, Journal of applied clinical medical physics.

[66]  R Calandrino,et al.  Quality assurance by systematic in vivo dosimetry: results on a large cohort of patients. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[67]  L. Archambault,et al.  Establishing action threshold for change in patient anatomy using EPID gamma analysis and PTV coverage for head and neck radiotherapy treatment , 2018, Medical physics.

[68]  Jan-Jakob Sonke,et al.  3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[69]  B J Mijnheer,et al.  A global calibration model for a-Si EPIDs used for transit dosimetry. , 2007, Medical physics.

[70]  B M C McCurdy,et al.  Model-based prediction of portal dose images during patient treatment. , 2013, Medical physics.

[71]  D. Georg,et al.  Implementation and validation of portal dosimetry with an amorphous silicon EPID in the energy range from 6 to 25 MV , 2007, Physics in medicine and biology.

[72]  Frank Verhaegen,et al.  A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging. , 2012, Medical physics.

[73]  M. V. van Herk,et al.  Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method. , 2006, Medical physics.

[74]  Eric C Ford,et al.  A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy. , 2015, Medical physics.

[75]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. , 1992, Physics in medicine and biology.

[76]  Todsaporn Fuangrod,et al.  First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions. , 2015, International journal of radiation oncology, biology, physics.

[77]  E. Ford,et al.  Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations. , 2015, Medical physics.

[78]  B Mijnheer,et al.  Error detection during VMAT delivery using EPID-based 3D transit dosimetry. , 2018, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[79]  S. Blake,et al.  Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy. , 2013, Medical physics.

[80]  P. Lambin,et al.  A literature review of electronic portal imaging for radiotherapy dosimetry. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[81]  Ria Bogaerts,et al.  Practical guidelines for the implementation of in vivo dosimetry with diodes in external radiotherapy with photon beams (entrance dose) , 2001 .

[82]  W Art Chaovalitwongse,et al.  Error Detection in Intensity-Modulated Radiation Therapy Quality Assurance Using Radiomic Analysis of Gamma Distributions. , 2018, International journal of radiation oncology, biology, physics.

[83]  Peter M McCowan,et al.  In vivo dosimetry for lung radiotherapy including SBRT. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[84]  M. Wendling,et al.  In vivo dosimetry with an electronic portal imaging device for prostate cancer radiotherapy with an endorectal balloon☆ , 2019, Physics and imaging in radiation oncology.

[85]  Philippe Lambin,et al.  3D in vivo dosimetry using megavoltage cone-beam CT and EPID dosimetry. , 2009, International journal of radiation oncology, biology, physics.

[86]  Frank Verhaegen,et al.  ESTRO ACROP: Technology for precision small animal radiotherapy research: Optimal use and challenges. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[87]  Frank Verhaegen,et al.  Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images , 2007, Physics in medicine and biology.

[88]  Peter B Greer,et al.  Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry. , 2005, Medical physics.

[89]  Clive Baldock,et al.  Direct-detection EPID dosimetry: investigation of a potential clinical configuration for IMRT verification , 2009, Physics in medicine and biology.

[90]  Savino Cilla,et al.  Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy , 2019, Journal of applied clinical medical physics.

[91]  Weixiong Zhang,et al.  Predicting gamma passing rates for portal dosimetry based IMRT QA using machine learning. , 2019, Medical physics.

[92]  Savino Cilla,et al.  A validation study of a dedicated software for an automated in vivo dosimetry control in radiotherapy , 2018, Medical & Biological Engineering & Computing.

[93]  An Investigation of dosimetric accuracy of a novel PRESAGE radiochromic sheet and its clinical applications , 2019, Journal of Physics: Conference Series.

[94]  J J Sonke,et al.  Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device. , 2003, Medical physics.

[95]  Ping Xia,et al.  Tolerance limits and methodologies for IMRT measurement‐based verification QA , 2018, Medical physics.

[96]  P. Greer,et al.  Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry. , 2010, Medical physics.

[97]  G. Verdú,et al.  Dosimetric capabilities of the Iview GT portal imager using MCNP5 monte carlo simulations , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[98]  F. Verhaegen,et al.  Electron beam treatment verification using measured and Monte Carlo predicted portal images , 2005, Physics in medicine and biology.

[99]  D. Georg,et al.  Independent dose calculations, concepts and models , 2010 .

[100]  M. Mahesh,et al.  Management of Radiotherapy Patients with Implanted Cardiac Pacemakers and Defibrillators: A Report of the AAPM TG-203. , 2019, Medical physics.

[101]  P. François,et al.  In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams. , 2011, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[102]  D. Gladstone,et al.  Cherenkov imaging in the potential roles of radiotherapy QA and delivery , 2017 .