Fluence-to-dose conversion coefficients based on the VIP-Man anatomical model and MCNPX code for monoenergetic neutrons above 20 MeV.

A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients has been calculated for high-energy neutrons using a whole-body anatomical model, VIP-Man, developed from the high-resolution transversal color photographic images of the National Library of Medicine's Visible Human Project. Organ dose calculations were performed using the Monte Carlo code MCNPX for 20 monoenergetic neutron beams between 20 MeV and 10,000 MeV under 6 different irradiation geometries: anterior-posterior, posterior-anterior, left lateral, right lateral, isotropic, and rotational. For neutron Monte Carlo calculations, results based on an image-based whole-body model were not available in the literature. The absorbed dose results for 24 major organs of VIP-Man are presented in the form of tables and selected figures that compare with those based on simplified mathematical phantoms reported in the literature. VIP-Man yields up to 40% larger values of effective dose and many organ doses, thus suggesting that the results reported in the past may not be conservative.

[1]  M. Pelliccioni,et al.  Fluence to Effective Dose Conversion Coefficients for Neutrons up to 10 TeV , 1997 .

[2]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[3]  A. Warshel Monte Carlo Calculations , 2002 .

[4]  H. Takada,et al.  Development of High Energy Transport Code HETC-3STEP Applicable to the Nuclear Reaction with Incident Energies above 20MeV , 1995 .

[5]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[6]  X. Xu,et al.  Sex-specific tissue weighting factors for effective dose equivalent calculations. , 1996, Health physics.

[7]  A. B. Chilton,et al.  Calculation of fast neutron depth-dose in the ICRU standard tissue phantom and the derivation of neutron fluence-to-dose-index conversion factors. , 1979, Radiation research.

[8]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[9]  M. Zankl,et al.  Some critical remarks on the use of sex-specific tissue weighting factors for effective dose equivalent calculations. , 1997, Health physics.

[10]  X. Xu,et al.  Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model , 2000, Physics in medicine and biology.

[11]  W. A. Coleman,et al.  The absorbed dose and dose equivalent from neutrons in the energy range 60 to 3000 MeV and protons in the energy range 400 to 3000 MeV , 1970 .

[12]  Xu Xg,et al.  Sex-specific tissue weighting factors for effective dose equivalent calculations. , 1996 .

[13]  Y. Yamaguchi Age-Dependant Effective Doses for Neutrons from Thermal to 18.3 MeV , 1994 .

[14]  C. Lushbaugh Guidance on Radiation Received in Space Activities , 1990 .

[15]  X. Xu,et al.  Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-Man tomographic model. , 2001, Health physics.

[16]  H. G. Hughes,et al.  Cross-Section Evaluations to 150 MeV for Accelerator-Driven Systems and Implementation in MCNPX , 1999 .

[17]  N. Hertel,et al.  Effective dose equivalents and effective doses for neutrons from 30 to 180 MeV , 1993 .

[18]  Y. Sakamoto,et al.  External Radiation Conversion Coefficients using Radiation Weighting Factor and Quality Factor for Neutron and Proton from 20 MeV to 10 GeV , 1998 .

[19]  G FAILLA,et al.  Dosimetry of ionizing radiation. , 1957, Medical sciences.

[20]  N. Hertel,et al.  Ambient dose equivalents, effective dose equivalents, and effective doses for neutrons from 10 to 20 MeV , 1993 .

[21]  A. Ferrari,et al.  AN UPDATE ABOUT FLUKA , 2022 .

[22]  G Drexler,et al.  Realistic computerized human phantoms. , 1994, Advances in space research : the official journal of the Committee on Space Research.

[23]  Y. Yariv,et al.  Intranuclear cascade calculation of high-energy heavy-ion interactions , 1979 .

[24]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  M Caon,et al.  An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations. , 1999, Physics in medicine and biology.

[26]  D. G. Jones A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon Irradiation , 1997 .

[27]  Icru.,et al.  Phantoms and Computational Models in Therapy, Diagnosis and Protection , 1992 .

[28]  D. Bartlett,et al.  Dosimetry for occupational exposure to cosmic radiation. , 1997, Radiation protection dosimetry.

[29]  H. Bertini Intranuclear-cascade calculation of the secondary nucleon spectra from nucleon-nucleus interactions in the energy range 340 to 2900 mev and comparisons with experiment , 1969 .

[30]  X. Xu,et al.  Conversion coefficients based on the VIP-Man anatomical model and EGS4. , 2001, Health physics.

[31]  A. Bozkurt,et al.  VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONS , 2000, Health physics.

[32]  J. E. Tanner,et al.  An extended tabulation of effective dose equivalent from neutrons incident on a male anthropomorphic phantom. , 1993, Health physics.