Computer-integrated revision total hip replacement surgery: concept and preliminary results
暂无分享,去创建一个
Peter Kazanzides | Russell H. Taylor | Leo Joskowicz | Jianhua Yao | Bill Williamson | Andrew Bzostek | Martin Börner | Rajesh Kumar | André Guéziec | Armin Lahmer | Alan D. Kalvin | Robert Van Vorhis | Alind Sahay | A. Kalvin | P. Kazanzides | A. Guéziec | B. Williamson | L. Joskowicz | R. Kumar | M. Börner | Jianhua Yao | R. V. Vorhis | A. Bzostek | Alind Sahay | A. Lahmer | Leo Joskowicz | R. Taylor
[1] T. Boult,et al. Registration of planar film radiographs with computed tomography , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.
[2] A Hamadeh,et al. Automated 3-dimensional computed tomographic and fluoroscopic image registration. , 1998, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[3] Roger Y. Tsai,et al. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..
[4] G. Glover,et al. An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981, Medical physics.
[5] E. Fishman,et al. Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. , 1988, Journal of computer assisted tomography.
[6] Russell H. Taylor,et al. A remote center of motion robotic arm for computer assisted surgery , 1996, Robotica.
[7] Rakesh Kumar,et al. Model-dependent inference of 3D information from a sequence of 2D images , 1992 .
[8] Peter Kazanzides,et al. An image-directed robotic system for precise orthopaedic surgery , 1994, IEEE Trans. Robotics Autom..
[9] Heang K. Tuy. Algorithm to reduce clip artifacts in CT images , 1992, Medical Imaging.
[10] A.M.M.A. Mohsen,et al. Image guided orthopaedic surgery design and analysis , 1995 .
[11] Henry Fuchs,et al. Optimal surface reconstruction from planar contours , 1977, SIGGRAPH.
[12] George Wolberg,et al. Digital image warping , 1990 .
[13] A. Jacobson,et al. Morphometric tools for landmark data , 1993 .
[14] Peter Kazanzides,et al. Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot , 1998, IEEE Transactions on Medical Imaging.
[15] S. Canale,et al. Campbell's operative orthopaedics , 1987 .
[16] K P Sherman,et al. A computer assisted orthopaedic surgical system for distal locking of intramedullary nails , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[17] Bill Williamson,et al. Using scout images to reduce metal artifacts in CT with application to revision total hip surgery , 1997, Medical Imaging.
[18] P. Rüegsegger,et al. Computed Tomography Reconstruction from Hollow Projections: An Application to In Vivo Evaluation of Artificial Hip Joints , 1979, Journal of computer assisted tomography.
[19] Klaus Radermacher,et al. A compact robot for image-guided orthopedic surgery: concept and preliminary results , 1997, CVRMed.
[20] Stephen J. Riederer,et al. Medical imaging [6] , 1995 .
[21] Philippe Cinquin,et al. Accurate calibration of cameras and range imaging sensor: the NPBS method , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.
[22] P. D. Wilson,et al. Revision total hip arthroplasty. , 1982, Clinical orthopaedics and related research.
[23] W. Maloney,et al. Segmental Cement Extraction at Revision Total Hip Arthroplasty , 1992, Clinical orthopaedics and related research.
[24] J. Bono,et al. Revision Total Hip Arthroplasty , 1999, Springer New York.
[25] Peter Kazanzides,et al. Anatomy-based registration of CT-scan and x-ray fluoroscopy data for intraoperative guidance of a surgical robot , 1998, Medical Imaging.
[26] Willi A. Kalender,et al. Algorithms for the reduction of CT artifacts caused by metallic implants , 1990, Medical Imaging.
[27] Jean Duchon,et al. Interpolation des fonctions de deux variables suivant le principe de la flexion des plaques minces , 1976 .
[28] Peter Kazanzides,et al. A surgical robot for total hip replacement surgery , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.
[29] J M Boone,et al. Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain. , 1991, Medical physics.
[30] Arridge,et al. MEDICAL IMAGING VI : IMAGE PROCESSING , 1992 .
[31] W. Kalender,et al. Reduction of CT artifacts caused by metallic implants. , 1987 .
[32] L. Joskowicz,et al. Computer Integrated Revision Total Hip Replacement Surgery : Preliminary Results , 1995 .
[33] P. Cinquin,et al. Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer. , 1995, Journal of image guided surgery.
[34] Tamon Inouye. Image Reconstruction with Limited Angle Projection Data , 1979, IEEE Transactions on Nuclear Science.
[35] Lerner Ej. Computer-integrated surgery. , 1997, New Jersey medicine : the journal of the Medical Society of New Jersey.
[36] Russell H. Taylor,et al. A system for percutaneous delivery of treatment with a fluoroscopically-guided robot , 1997, CVRMed.
[37] Henry Stark,et al. Image recovery: Theory and application , 1987 .
[38] B. E. Oppenheim,et al. Reconstruction tomography from incomplete projections , 1975 .