Measurements of fundamental properties of homogeneous tissue phantoms

Abstract. We present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters’ estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities. A more detailed study of phantom surface roughness was carried out with the optical profilometer. Reflectance, transmittance, and collimated transmittance of phantoms were measured using an integrating-sphere spectrometer setup. The scattering and absorption coefficients were calculated with the inverse adding-doubling method. The reduced scattering coefficient at 930 nm was found to be 1.57±0.14  mm−1 and the absorption was 0.22±0.03  mm−1. The retrieved optical properties of phantoms are in agreement with the data found in the literature for real human tissues.

[1]  M. Hartmann,et al.  Light scattering by small particles. Von H. C. VANDE HULST. New York: Dover Publications, Inc. 1981. Paperback, 470 S., 103 Abb. und 46 Tab., US $ 7.50 , 1984 .

[2]  Małgorzata Jędrzejewska-Szczerska,et al.  Theoretical and experimental investigation of low-noise optoelectronic system configurations for low-coherent optical signal detection , 2006 .

[3]  Rolf B. Saager,et al.  Multilayer silicone phantoms for the evaluation of quantitative optical techniques in skin imaging , 2010, BiOS.

[4]  Robert J. Nordstrom,et al.  Phantoms as standards in optical measurements , 2011, BiOS.

[5]  J. Pickering,et al.  Double-integrating-sphere system for measuring the optical properties of tissue. , 1993, Applied optics.

[6]  Erkki Alarousu,et al.  Noninvasive glucose sensing in scattering media using OCT, PAS, and TOF techniques , 2004, Saratov Fall Meeting.

[7]  Tianheng Wang,et al.  Optical scattering coefficient estimated by optical coherence tomography correlates with collagen content in ovarian tissue. , 2011, Journal of biomedical optics.

[8]  Jeeseong Hwang,et al.  Fabrication and characterization of a multilayered optical tissue model with embedded scattering microspheres in polymeric materials , 2012, Biomedical optics express.

[9]  Adam Mazikowski,et al.  Modeling of noncontact temperature measurement system using multiwavelength pyrometry , 2001, Optoelectronic and Electronic Sensors.

[10]  M. Gnyba,et al.  Fiber-optic temperature sensor using low-coherence interferometry , 2008 .

[11]  T. Joshua Pfefer,et al.  Characterizing the point spread function of retinal OCT devices with a model eye-based phantom , 2011, CLEO: 2011 - Laser Science to Photonic Applications.

[12]  A. Karim,et al.  Multimodal optical studies of single and clustered colloidal quantum dots for the long-term optical property evaluation of quantum dot-based molecular imaging phantoms , 2012, Biomedical optics express.

[13]  Daniel V. Samarov,et al.  Algorithm validation using multicolor phantoms , 2012, Biomedical optics express.

[14]  Xiangqun Xu,et al.  Optical coherence tomography to investigate optical properties of blood during coagulation. , 2011, Journal of biomedical optics.

[15]  Dirk Faber,et al.  Functional optical coherence tomography : spatially resolved measurements of optical properties , 2005 .

[16]  M. Jedrzejewska-Szczerska,et al.  Shaping coherence function of sources used in low-coherent measurement techniques , 2006 .

[17]  Steven L. Jacques,et al.  Reflectance confocal microscopy of optical phantoms , 2012, Biomedical optics express.

[18]  Vesa Korhonen,et al.  Optical sensing of a pulsating liquid in a brain-mimicking phantom , 2013, European Conference on Biomedical Optics.

[19]  Kelsey M. Kennedy,et al.  Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography , 2012, Biomedical optics express.

[20]  Daniel V. Samarov,et al.  Designing microarray phantoms for hyperspectral imaging validation , 2012, Biomedical optics express.

[21]  Jessica C. Ramella-Roman,et al.  Introduction: Feature Issue on Phantoms for the Performance Evaluation and Validation of Optical Medical Imaging Devices , 2012, Biomedical optics express.

[22]  A. Welch,et al.  Determining the optical properties of turbid mediaby using the adding-doubling method. , 1993, Applied optics.

[23]  M S Patterson,et al.  INDIRECT VERSUS DIRECT TECHNIQUES FOR THE MEASUREMENT OF THE OPTICAL PROPERTIES OF TISSUES , 1987, Photochemistry and photobiology.

[24]  Scott A Prahl,et al.  Preparation and characterization of polyurethane optical phantoms. , 2006, Journal of biomedical optics.

[25]  Risto Myllylä,et al.  APPLICATION OF LASERS AND LASER-OPTICAL METHODS IN LIFE SCIENCES Non-invasive, MRI-compatible fibreoptic device for functional near-IR reflectometry of human brain , 2011 .

[26]  Alexander V. Priezzhev,et al.  Multilayer tissue phantoms with embedded capillary system for OCT and DOCT imaging , 2011, European Conference on Biomedical Optics.

[27]  Jeff S. Xu,et al.  Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function , 2010, Journal of visualized experiments : JoVE.

[28]  V. V. Tuchin Light scattering study of tissues , 1997 .

[29]  Jessica C. Ramella-Roman,et al.  Microfluidics based phantoms of superficial vascular network , 2012, Biomedical optics express.

[30]  B. Pogue,et al.  Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. , 2006, Journal of biomedical optics.

[31]  Daniel X. Hammer,et al.  Retina-simulating phantom for optical coherence tomography , 2013, Journal of biomedical optics.

[32]  Bruce J. Tromberg,et al.  Tissue phantoms in multicenter clinical trials for diffuse optical technologies , 2012, Biomedical optics express.

[33]  Valery V. Tuchin,et al.  Multi-layered tissue head phantoms for noninvasive optical diagnostics , 2015 .

[34]  M. Strakowski,et al.  Optical low-coherence interferometry for selected technical applications , 2008 .

[35]  M. Jędrzejewska-Szczerska,et al.  Investigation of photothermolysis therapy of human skin diseases using optical phantoms , 2015, Other Conferences.

[36]  A. P. Popov,et al.  Skin phantoms with realistic vessel structure for OCT measurements , 2010, Laser Applications in Life Sciences.

[37]  Quanzeng Wang,et al.  Experimental and theoretical evaluation of a fiber-optic approach for optical property measurement in layered epithelial tissue. , 2010, Applied optics.

[38]  J. Mourant,et al.  Predictions and measurements of scattering and absorption over broad wavelength ranges in tissue phantoms. , 1997, Applied optics.

[39]  G. N. Rao,et al.  Synthesis, characterization and optical properties of zinc oxide nanoparticles , 2013, International Nano Letters.

[40]  S. Jacques Optical properties of biological tissues: a review , 2013, Physics in medicine and biology.

[41]  A. Welch,et al.  A review of the optical properties of biological tissues , 1990 .

[42]  Matti Kinnunen,et al.  Light Propagation in NIR Spectroscopy of the Human Brain , 2014, IEEE Journal of Selected Topics in Quantum Electronics.

[43]  Tom Lister,et al.  Optical properties of human skin , 2012, Journal of biomedical optics.

[44]  Jessica C. Ramella-Roman,et al.  Three-dimensional phantoms for curvature correction in spatial frequency domain imaging , 2012, Biomedical optics express.

[45]  V. Tuchin Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis , 2000 .

[46]  Valery V. Tuchin,et al.  OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW , 2011 .

[47]  A. Rück,et al.  Design and Characterisation of a Tissue Phantom System for Optical Diagnostics , 1998, Lasers in Medical Science.

[48]  Hui Gong,et al.  A SIMPLE METHOD FOR PREDICTION OF THE REDUCED SCATTERING COEFFICIENT IN TISSUE-SIMULATING PHANTOMS , 2010 .

[49]  A. Amelink,et al.  Scattering phase function spectrum makes reflectance spectrum measured from Intralipid phantoms and tissue sensitive to the device detection geometry , 2012, Biomedical optics express.

[50]  H. V. Hulst Light Scattering by Small Particles , 1957 .