A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by the choice of one adjustable parameter. A feasible image has been defined as one that is consistent with the initial data (i.e. it is an image that, if truly a source of radiation in a patient, could have generated the initial data by the Poisson process that governs radioactive disintegration). The fundamental ideas of Bayesian reconstruction are discussed, along with the use of an entropy prior with an adjustable contrast parameter, the use of likelihood with data increment parameters as conditional probability, and the development of the new fast maximum a posteriori with entropy (FMAPE) Algorithm by the successive substitution method. It is shown that in the maximum likelihood estimator (MLE) and FMAPE algorithms, the only correct choice of initial image for the iterative procedure in the absence of a priori knowledge about the image configuration is a uniform field.

[1]  F. B. Hildebrand,et al.  Introduction To Numerical Analysis , 1957 .

[2]  E. Jaynes Information Theory and Statistical Mechanics , 1957 .

[3]  B. Frieden Restoring with maximum likelihood and maximum entropy. , 1972, Journal of the Optical Society of America.

[4]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[5]  B. Roy Frieden,et al.  Restoring with maximum entropy. III. Poisson sources and backgrounds , 1978 .

[6]  H. Trussell The relationship between image restoration by the maximum a posteriori method and a maximum entropy method , 1980 .

[7]  E. Jaynes On the rationale of maximum-entropy methods , 1982, Proceedings of the IEEE.

[8]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[9]  B. Frieden Unified theory for estimating frequency-of-occurrence laws and optical objects , 1983 .

[10]  E. J. Hoffman,et al.  ECAT III -- Basic Design Considerations , 1983, IEEE Transactions on Nuclear Science.

[11]  E. Pike Probability, Statistical Optics and Data Testing , 1983 .

[12]  John Skilling,et al.  Maximum entropy method in image processing , 1984 .

[13]  J. Skilling,et al.  Maximum entropy image reconstruction: general algorithm , 1984 .

[14]  Michael I. Miller,et al.  The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography , 1985, IEEE Transactions on Nuclear Science.

[15]  S. F. Gull,et al.  The Entropy of an Image , 1985 .

[16]  Edward S. Meinel,et al.  Origins of linear and nonlinear recursive restoration algorithms , 1986 .

[17]  C. Metz ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.

[18]  E. T. Jaynes,et al.  Maximum Entropy and Bayesian Methods in Applied Statistics: Monkeys, Kangaroos, and N , 1986 .

[19]  Begnaud Francis Hildebrand,et al.  Introduction to numerical analysis: 2nd edition , 1987 .

[20]  L. J. Thomas,et al.  Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[21]  Stuart Geman,et al.  Statistical methods for tomographic image reconstruction , 1987 .

[22]  E. Veklerov,et al.  Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing , 1987, IEEE Transactions on Medical Imaging.

[23]  H. Hart,et al.  Bayesian Image Processing in Two Dimensions , 1987, IEEE Transactions on Medical Imaging.

[24]  E. Levitan,et al.  A Maximum a Posteriori Probability Expectation Maximization Algorithm for Image Reconstruction in Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[25]  K. Lange,et al.  A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission Tomography , 1987, IEEE Transactions on Medical Imaging.

[26]  E. Veklerov,et al.  The high sensitivity of the maximum likelihood estimator method of tomographic image reconstruction , 1987 .

[27]  Z. Liang Statistical Models Of A Priori Information For Image Processing , 1988, Medical Imaging.

[28]  Z Liang,et al.  Study and performance evaluation of statistical methods in image processing. , 1988, Computers in biology and medicine.

[29]  E. Veklerov,et al.  MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule , 1988 .

[30]  J Llacer,et al.  Feasible images and practical stopping rules for iterative algorithms in emission tomography. , 1989, IEEE transactions on medical imaging.

[31]  Jorge Nunez,et al.  Maximum Entropy And The Concept Of Feasibility In Tomographic Image Reconstruction , 1989, Medical Imaging.

[32]  R. Jaszczak,et al.  On Bayesian image reconstruction from projections: uniform and nonuniform a priori source information. , 1989, IEEE transactions on medical imaging.

[33]  E. Veklerov,et al.  The use of a stopping rule in iterative image reconstruction , 1991 .

[34]  Chin-Tu Chen,et al.  Data Augmentation Schemes Applied to Image Restoration , 1992 .