A Novel Method to Capture the Onset of Dynamic Electrocardiographic Ischemic Changes and its Implications to Arrhythmia Susceptibility

Background This study investigates the hypothesis that morphologic analysis of intracardiac electrograms provides a sensitive approach to detect acute myocardial infarction or myocardial infarction‐induced arrhythmia susceptibility. Large proportions of irreversible myocardial injury and fatal ventricular tachyarrhythmias occur in the first hour after coronary occlusion; therefore, early detection of acute myocardial infarction may improve clinical outcomes. Methods and Results We developed a method that uses the wavelet transform to delineate electrocardiographic signals, and we have devised an index to quantify the ischemia‐induced changes in these signals. We recorded body‐surface and intracardiac electrograms at baseline and following myocardial infarction in 24 swine. Statistically significant ischemia‐induced changes after the initiation of occlusion compared with baseline were detectable within 30 seconds in intracardiac left ventricle (P<0.0016) and right ventricle–coronary sinus (P<0.0011) leads, 60 seconds in coronary sinus leads (P<0.0002), 90 seconds in right ventricle leads (P<0.0020), and 360 seconds in body‐surface electrocardiographic signals (P<0.0022). Intracardiac leads exhibited a higher probability of detecting ischemia‐induced changes than body‐surface leads (P<0.0381), and the right ventricle–coronary sinus configuration provided the highest sensitivity (96%). The 24‐hour ECG recordings showed that the ischemic index is statistically significantly increased compared with baseline in lead I, aVR, and all precordial leads (P<0.0388). Finally, we showed that the ischemic index in intracardiac electrograms is significantly increased preceding ventricular tachyarrhythmic events (P<0.0360). Conclusions We present a novel method that is capable of detecting ischemia‐induced changes in intracardiac electrograms as early as 30 seconds following myocardial infarction or as early as 12 minutes preceding tachyarrhythmic events.

[1]  B R Chaitman,et al.  Improved Efficiency of Treadmill Exercise Testing Using a Multiple Lead ECG System and Basic Hemodynamic Exercise Response , 1978, Circulation.

[2]  R. Cohen,et al.  A spectral analysis of the high frequency QRS potentials observed during acute myocardial ischemia in dogs. , 1990, International journal of cardiology.

[3]  Motohisa Osaka,et al.  Comparison of Body Surface Potential and Laplacian Mapping with Epicardial Mapping for Detection of Cardiac Ischemia in Pigs , 1998 .

[4]  E. W. Hancock,et al.  AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American , 2009, Journal of the American College of Cardiology.

[5]  H. W. Duncan,et al.  Limitations of the standard transthoracic electrocardiogram in detecting subendocardial ischemia. , 1980, American heart journal.

[6]  R. Califf,et al.  Continuously updated 12-lead ST-segment recovery analysis for myocardial infarct artery patency assessment and its correlation with multiple simultaneous early angiographic observations. , 1993, The American journal of cardiology.

[7]  J S Alpert,et al.  Myocardial infarction redefined--a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. , 2000, Journal of the American College of Cardiology.

[8]  A. Bonny,et al.  Implantable cardioverter defibrillators after myocardial infarction. , 2009, Cardiovascular journal of Africa.

[9]  I. Menown,et al.  Optimizing the initial 12-lead electrocardiographic diagnosis of acute myocardial infarction. , 2000, European heart journal.

[10]  Pablo Laguna,et al.  Depolarization Changes During Acute Myocardial Ischemia by Evaluation of QRS Slopes: Standard Lead and Vectorial Approach , 2011, IEEE Transactions on Biomedical Engineering.

[11]  A. Castellanos,et al.  Sudden cardiac death. Structure, function, and time-dependence of risk. , 1992, Circulation.

[12]  O Pahlm,et al.  Changes in high-frequency QRS components are more sensitive than ST-segment deviation for detecting acute coronary artery occlusion. , 2000, Journal of the American College of Cardiology.

[13]  S. Solomon,et al.  Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. , 2005, The New England journal of medicine.

[14]  R. Califf,et al.  Prognostic implications of TIMI flow grade in the infarct related artery compared with continuous 12-lead ST-segment resolution analysis. Reexamining the "gold standard" for myocardial reperfusion assessment. , 2000, Journal of the American College of Cardiology.

[15]  S. Solomon,et al.  Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. , 2005, The New England journal of medicine.

[16]  Pablo Laguna,et al.  A wavelet-based ECG delineator: evaluation on standard databases , 2004, IEEE Transactions on Biomedical Engineering.

[17]  William J. Hall,et al.  Quantitation of ventricular repolarization: a new approach , 1988, Proceedings. Computers in Cardiology 1988.

[18]  Vivek Y. Reddy,et al.  A Novel Lead Configuration for Optimal Spatio-Temporal Detection of Intracardiac Repolarization Alternans , 2011, Circulation. Arrhythmia and electrophysiology.

[19]  Stéphane Mallat,et al.  A Theory for Multiresolution Signal Decomposition: The Wavelet Representation , 1989, IEEE Trans. Pattern Anal. Mach. Intell..

[20]  Olle Pahlm,et al.  Comparison of high-frequency QRS components and ST-segment elevation to detect and quantify acute myocardial ischemia. , 2010, Journal of electrocardiology.

[21]  B.G. Celler,et al.  Automatic measurement of the QRS onset and offset in individual ECG leads , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  J. Ruskin,et al.  Electrophysiologic testing in survivors of cardiac arrest. , 1987, Circulation.

[23]  Friedberg Ck Computers in cardiology. , 1970 .

[24]  J J Heger,et al.  Sudden cardiac death. , 1998, Circulation.

[25]  E. W. Hancock,et al.  AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part IV: the ST segment, T and U waves, and the QT interval: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the , 2009, Journal of the American College of Cardiology.

[26]  C. Conti,et al.  Silent ischemia: clinical relevance. , 2012, Journal of the American College of Cardiology.

[27]  H. Calkins,et al.  Intracardiac J-point elevation before the onset of polymorphic ventricular tachycardia and ventricular fibrillation in patients with an implantable cardioverter-defibrillator. , 2012, Heart rhythm.

[28]  M. Keltai,et al.  Early atrial fibrillation during evolving myocardial infarction: a consequence of impaired left atrial perfusion. , 1987, Circulation.

[29]  R J Cohen,et al.  High Frequency Electrocardiography of Three Orthogonal Leads in Dogs During a Coronary Artery Occlusion , 1989, Pacing and clinical electrophysiology : PACE.

[30]  K. Wegscheider,et al.  Extent of ST-segment deviation in a single electrocardiogram lead 90 min after thrombolysis as a predictor of medium-term mortality in acute myocardial infarction , 2001, The Lancet.

[31]  R J Cohen,et al.  Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty. , 1987, Circulation.

[32]  Hugo A. Katus,et al.  Myocardial infarction redefined--a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. , 2000, European heart journal.

[33]  R. Holland,et al.  TQ-ST segment mapping: critical review and analysis of current concepts. , 1977, The American journal of cardiology.

[34]  Anna Engeln Initial Clinical Results Using Intracardiac Electrogram Monitoring to Detect and Alert Patients during Coronary Plaque Rupture and Ischemia , 2011 .

[35]  P. Savard,et al.  Body surface potential mapping of ST-segment shift in patients undergoing percutaneous transluminal coronary angioplasty. Correlations with the ECG and vectorcardiogram. , 1993, Journal of electrocardiology.

[36]  M. Krucoff,et al.  Potential of an intracardiac electrogram for the rapid detection of coronary artery occlusion. , 2005, Cardiovascular revascularization medicine : including molecular interventions.

[37]  J. Fisher,et al.  Intracardiac Electrode Detection of Early or Subendocardial Ischemia * , 1982, Pacing and clinical electrophysiology : PACE.

[38]  P. Laguna,et al.  New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications , 2006, Medical and Biological Engineering and Computing.

[39]  P Caminal,et al.  Automatic detection of wave boundaries in multilead ECG signals: validation with the CSE database. , 1994, Computers and biomedical research, an international journal.