False Positive Marks on Unsuspicious Screening Mammography with Computer-Aided Detection

The contribution of computer-aided detection (CAD) systems as an interpretive aid in screening mammography can be hampered by a high rate of false positive detections. Specificity, false positive rate, and ease of dismissing false positive marks from two CAD systems are retrospectively evaluated. One hundred screening mammographic studies with a BI-RADS assessment code of 1 or 2 and at least 2-year normal mammographic follow-up were retrospectively reviewed using two CAD systems. Breast density, CAD marks, and radiologist's ease of dismissing false positive marks were recorded. Specificities from the two CAD versions considering all marks were 23% and 15% (p value = 0.07); mass marks, 35% and 17% (p value < 0.01); and calcification marks 62% and 75% (p value = 0.01). The two CAD versions did not differ regarding mean and median marks per case for all marks (2.3, 2.0 and 2.3, 2.0, p value = 0.65) or mass marks (1.6, 1.0 and 1.8, 2.0, p value = 0.15), but differed for calcification marks (0.8, 0 and 0.5, 0, p value < 0.01). Slightly higher specificity and fewer marks per case observed in dense breasts did not reach statistical significance. The reviewing radiologist classified most marks from both CAD systems (84% and 88%) as very easy/easy to dismiss. The two CAD versions had small differences in specificity and false positive marks. Differences, although not statistically significant, in specificities and false positive rates between dense and non-dense breasts warrant further research. Most false positive marks are easily dismissed and should not affect clinical performance.

[1]  Wei Qian,et al.  CAD-aided mammogram training. , 2005, Academic radiology.

[2]  Margarita L Zuley,et al.  Can computer-aided detection with double reading of screening mammograms help decrease the false-negative rate? Initial experience. , 2004, Radiology.

[3]  P. Taylor,et al.  Computer-aided detection in the United Kingdom National Breast Screening Programme: prospective study. , 2005, Radiology.

[4]  Luisa P. Wallace,et al.  Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system. , 2004, Journal of the National Cancer Institute.

[5]  Stefano Ciatto,et al.  Comparison of two commercial systems for computer-assisted detection (CAD) as an aid to interpreting screening mammograms. , 2004, La Radiologia medica.

[6]  W. P. Evans,et al.  Re: Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system. , 2004, Journal of the National Cancer Institute.

[7]  L. Tabár,et al.  Potential contribution of computer-aided detection to the sensitivity of screening mammography. , 2000, Radiology.

[8]  T. Freer,et al.  Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. , 2001, Radiology.

[9]  Thomas Boehm,et al.  Influence of breast lesion size and histologic findings on tumor detection rate of a computer-aided detection system. , 2003, Radiology.

[10]  Joachim Böttcher,et al.  Effect of Breast Density on Computer Aided Detection , 2005, Journal of Digital Imaging.

[11]  S. Astley,et al.  Single reading with computer-aided detection for screening mammography. , 2008, The New England journal of medicine.

[12]  KathleenR. Brandt,et al.  Screening mammograms: interpretation with computer-aided detection--prospective evaluation. , 2006, Radiology.

[13]  Priscilla J Slanetz,et al.  Prospective assessment of computer-aided detection in interpretation of screening mammography. , 2006, AJR. American journal of roentgenology.

[14]  Susan M Astley,et al.  Single reading with computer-aided detection and double reading of screening mammograms in the United Kingdom National Breast Screening Program. , 2006, Radiology.

[15]  P. Skaane,et al.  Effect of computer-aided detection on independent double reading of paired screen-film and full-field digital screening mammograms. , 2007, AJR. American journal of roentgenology.

[16]  Debra M Ikeda,et al.  Computer-aided detection with screening mammography in a university hospital setting. , 2005, Radiology.

[17]  Stefano Ciatto,et al.  Does computer-aided detection (CAD) contribute to the performance of digital mammography in a self-referred population? , 2008, Breast Cancer Research and Treatment.

[18]  R. Birdwell The preponderance of evidence supports computer-aided detection for screening mammography. , 2009, Radiology.

[19]  L. Philpotts,et al.  Can computer-aided detection be detrimental to mammographic interpretation? , 2009, Radiology.

[20]  Christina Ilvento,et al.  Improved cancer detection using computer-aided detection with diagnostic and screening mammography: prospective study of 104 cancers. , 2006, AJR. American journal of roentgenology.

[21]  Woo Kyung Moon,et al.  Screening mammography-detected cancers: sensitivity of a computer-aided detection system applied to full-field digital mammograms. , 2007, Radiology.

[22]  B. Zheng,et al.  Soft-copy mammographic readings with different computer-assisted detection cuing environments: preliminary findings. , 2001, Radiology.

[23]  J. Reynolds,et al.  Impact of computer-aided detection in a regional screening mammography program. , 2005, AJR. American journal of roentgenology.

[24]  Jeffrey W Hoffmeister,et al.  Detection of breast cancer with full-field digital mammography and computer-aided detection. , 2009, AJR. American journal of roentgenology.

[25]  Janice C. Honeyman-Buck,et al.  Comparison of Two Commercial CAD Systems for Digital Mammography , 2008, Journal of Digital Imaging.

[26]  T. Vehmas,et al.  Effect of computer-aided detection on mammographic performance: experimental study on readers with different levels of experience , 2006, Acta radiologica.

[27]  Wei Qian,et al.  CAD-Aided Mammogram Training1 , 2005 .

[28]  Jeffrey W Hoffmeister,et al.  Evaluation of breast cancer with a computer‐aided detection system by mammographic appearance and histopathology , 2005, Cancer.

[29]  Rachel F Brem,et al.  Improvement in sensitivity of screening mammography with computer-aided detection: a multiinstitutional trial. , 2003, AJR. American journal of roentgenology.

[30]  C. D'Orsi,et al.  Influence of computer-aided detection on performance of screening mammography. , 2007, The New England journal of medicine.

[31]  Jeffrey W Hoffmeister,et al.  Impact of breast density on computer-aided detection for breast cancer. , 2005, AJR. American journal of roentgenology.

[32]  M. Gromet Comparison of computer-aided detection to double reading of screening mammograms: review of 231,221 mammograms. , 2008, AJR. American journal of roentgenology.