Minimizing Graft Preparation Failure in Descemet Membrane Endothelial Keratoplasty

Purpose: To report the failure rate of 2 graft preparation techniques for Descemet membrane endothelial keratoplasty (DMEK) and to evaluate how to minimize graft preparation failure. Methods: Retrospective, nonrandomized study at an eye bank specialized in graft preparation for lamellar keratoplasty. For 1416 donor corneas, the DMEK graft preparation failure rate was evaluated for 2 different techniques, technique I: “Standardized traditional technique” (n = 341) and technique II: “Standardized no-touch technique” (n = 933), and for grafts that were converted from technique II to technique I during preparation (n = 142). Results: The overall failure rate averaged 3.9% (55/1416): 7.0% (24/341) for technique I and 2.9% (31/1075) for technique II (P < 0.05). Tissue preparations which were converted from technique II to technique I failed in 13.4% (19/142), whereas for grafts that were entirely prepared by technique II, the failure rate was only 1.3% (12/933). The endothelial cell density decrease (before compared with after preparation) did not differ for both techniques (1.1% vs. 0.2%, P > 0.05). Conclusions: Various DMEK graft preparation techniques may provide failure rates of <4%. A “no-touch preparation” approach (technique II) may combine good graft quality (completely intact endothelial cell layer, ie, negligible preparation-induced endothelial cell density decrease) with low risk of dissection failure, leaving the possibility of conversion to “traditional preparation” (technique I) as a backup method.

[1]  R. Chuck,et al.  Revisiting the Cornea and Trabecular Meshwork Junction With 2-Photon Excitation Fluorescence Microscopy , 2017, Cornea.

[2]  M. Balda,et al.  Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty , 2016, British Journal of Ophthalmology.

[3]  E. G. Groeneveld-van Beek,et al.  Donor Tissue Preparation for Bowman Layer Transplantation , 2016, Cornea.

[4]  O. Damour,et al.  Validation of an endothelial roll preparation for Descemet Membrane Endothelial Keratoplasty by a cornea bank using “no touch” dissection technique , 2016, Cell and Tissue Banking.

[5]  S. Ferrari,et al.  Descemet membrane endothelial keratoplasty tissue preparation from donor corneas using a standardized submerged hydro-separation method. , 2014, American journal of ophthalmology.

[6]  S. Ferrari,et al.  DMEK lenticule preparation from donor corneas using a novel ‘SubHyS’ technique followed by anterior corneal dissection , 2014, British Journal of Ophthalmology.

[7]  F. Kruse,et al.  Use of Accidentally Torn Descemet Membrane to Successfully Complete Descemet Membrane Endothelial Keratoplasty , 2013, Cornea.

[8]  Zhiguo He,et al.  Novel technique for the preparation of corneal grafts for descemet membrane endothelial keratoplasty. , 2013, American journal of ophthalmology.

[9]  E. G. Groeneveld-van Beek,et al.  Standardized ‘no‐touch’ donor tissue preparation for DALK and DMEK: harvesting undamaged anterior and posterior transplants from the same donor cornea , 2013, Acta ophthalmologica.

[10]  U. Schlötzer-Schrehardt,et al.  A Stepwise Approach to Donor Preparation and Insertion Increases Safety and Outcome of Descemet Membrane Endothelial Keratoplasty , 2011, Cornea.

[11]  G. Kymionis,et al.  Automated donor tissue preparation for descemet membrane automated endothelial keratoplasty (DMAEK): an experimental study. , 2010, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[12]  D. Ponzin,et al.  Stromal support for Descemet's membrane endothelial keratoplasty. , 2010, Ophthalmology.

[13]  E. G. Groeneveld-van Beek,et al.  More efficient use of donor corneal tissue with Descemet membrane endothelial keratoplasty (DMEK): two lamellar keratoplasty procedures with one donor cornea , 2010, British Journal of Ophthalmology.

[14]  K. Jirsova,et al.  Descemet membrane endothelial keratoplasty with a stromal rim (DMEK-S) , 2009, British Journal of Ophthalmology.

[15]  Caroline L. Speck,et al.  A Comprehensive Analysis of Eye Bank-Prepared Posterior Lamellar Corneal Tissue for Use in Endothelial Keratoplasty , 2009, Cornea.

[16]  F. Price,et al.  Descemet membrane automated endothelial keratoplasty: hybrid technique combining DSAEK stability with DMEK visual results. , 2009, Journal of cataract and refractive surgery.

[17]  G. Melles,et al.  Donor tissue preparation for Descemet membrane endothelial keratoplasty , 2008, Journal of cataract and refractive surgery.

[18]  G. Melles Posterior lamellar keratoplasty: DLEK to DSEK to DMEK. , 2006, Cornea.

[19]  Ronald E. Smith,et al.  Technique for Preparation of the Corneal Endothelium-Descemet Membrane Complex for Transplantation , 2006, Cornea.

[20]  G. Melles,et al.  Transplantation of Descemet's Membrane Carrying Viable Endothelium Through a Small Scleral Incision , 2002, Cornea.

[21]  Technique of Preparation , 1935 .