Effect of alternative crosslinking methods on the low strain rate viscoelastic properties of bovine pericardial bioprosthetic material.

Early failures of bovine pericardial heart valves have been due to leaflet perforation/tearing and calcification. Since glutaraldehyde fixation has been shown to produce marked changes in leaflet mechanics and has been linked to the development of calcification, alternative crosslinking techniques have been suggested as means to overcome these obstacles. We have examined the low strain rate viscoelastic behavior of bovine pericardium: (1) fresh; (2) chemically treated with glutaraldehyde, cyanimide, or polyglycidyl ether; or (3) physically treated by freeze-drying or heat-drying. Shrinkage temperature tests were conducted to assess intrahelical crosslinking. Polyglycidyl ether and glutaraldehyde both produced substantial crosslinking, with the shrinkage temperature rising above 80 degrees C. Mechanical changes were nearly equivalent, both showing decreased stress relaxation and increased extensibility consistent with intrahelical crosslinking and shrinkage during fixation. Cyanimide, known to crosslink pure collagen materials, showed no evidence of crosslinking intact tissue. Heat-drying, also effective in pure collagen preparations, produced an increase in UTS and tissue modulus, but otherwise left the tissue unchanged. Freeze-drying had no mechanical effect, and therefore provides an attractive means for the storage of connective tissues for later mechanical testing.

[1]  A. Barker,et al.  A study of the effects of glutaraldehyde and formaldehyde on the mechanical behaviour of bovine pericardium. , 1982, Biomaterials.

[2]  H. Koyanagi,et al.  Epoxy Compounds As a New Cross‐Linking Agent for Porcine Aortic Leaflets: Subcutaneous Implant Studies in Rats , 1989, Journal of cardiac surgery.

[3]  F. Nistal,et al.  Degenerative pathologic findings after long-term implantation of bovine pericardial bioprosthetic heart valves. , 1988, The Journal of thoracic and cardiovascular surgery.

[4]  E. Trowbridge,et al.  Evidence that deformations which occur during mechanical conditioning of bovine pericardium are not permanent. , 1986, Biomaterials.

[5]  M. Ionescu,et al.  Clinical durability of the pericardial xenograft valve: ten years experience with mitral replacement. , 1982, The Annals of thoracic surgery.

[6]  D R Boughner,et al.  Tissue Mechanics of Canine Pericardium in Different Test Environments: Evidence for Time‐Dependent Accommodation, Absence of Plasticity, and New Roles for Collagen and Elastin , 1981, Circulation research.

[7]  D R Boughner,et al.  The glutaraldehyde-stabilized porcine aortic valve xenograft. II. Effect of fixation with or without pressure on the tensile viscoelastic properties of the leaflet material. , 1984, Journal of Biomedical Materials Research.

[8]  J M Lee,et al.  The bovine pericardial xenograft: II. Effect of tethering or pressurization during fixation on the tensile viscoelastic properties of bovine pericardium. , 1989, Journal of biomedical materials research.

[9]  Lee Jm,et al.  The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium , 1989 .

[10]  F. Silver,et al.  Evaluation of collagen crosslinking techniques. , 1983, Biomaterials, medical devices, and artificial organs.

[11]  J. M. Lee Tensile Viscoelastic Properties Of Bioprosthetic Heart Valve Materials And Of The Pericardium , 1982 .

[12]  F. Loop,et al.  In vivo hemodynamic comparison of porcine and pericardial valves. , 1985, The Journal of thoracic and cardiovascular surgery.

[13]  L Gonzalez-Lavin,et al.  Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration. , 1987, Circulation.

[14]  L. Cohn,et al.  Hemodynamic and pathologic evaluation of a unileaflet pericardial bioprosthetic valve. , 1988, The Journal of thoracic and cardiovascular surgery.

[15]  G L Hallman,et al.  Valve failure with the Ionescu-Shiley bovine pericardial bioprosthesis: analysis of 2680 patients. , 1985, Journal of vascular surgery.

[16]  D R Boughner,et al.  Mechanical suitability of glycerol-preserved human dura mater for construction of prosthetic cardiac valves. , 1984, Biomaterials.

[17]  I Vesely,et al.  A multipurpose tissue bending machine. , 1985, Journal of biomechanics.

[18]  R. Levy,et al.  The role of glutaraldehyde-induced cross-links in calcification of bovine pericardium used in cardiac valve bioprostheses. , 1987, The American journal of pathology.