RELIABILITY OF A NEW BIOKINETIC MODEL OF ZIRCONIUM IN INTERNAL DOSIMETRY: PART II, PARAMETER SENSITIVITY ANALYSIS

The reliability of biokinetic models is essential for the assessment of internal doses and a radiation risk analysis for the public and occupational workers exposed to radionuclides. In the present study, a method for assessing the reliability of biokinetic models by means of uncertainty and sensitivity analysis was developed. In the first part of the paper, the parameter uncertainty was analyzed for two biokinetic models of zirconium (Zr); one was reported by the International Commission on Radiological Protection (ICRP), and one was developed at the Helmholtz Zentrum München–German Research Center for Environmental Health (HMGU). In the second part of the paper, the parameter uncertainties and distributions of the Zr biokinetic models evaluated in Part I are used as the model inputs for identifying the most influential parameters in the models. Furthermore, the most influential model parameter on the integral of the radioactivity of 95Zr over 50 y in source organs after ingestion was identified. The results of the systemic HMGU Zr model showed that over the first 10 d, the parameters of transfer rates between blood and other soft tissues have the largest influence on the content of Zr in the blood and the daily urinary excretion; however, after day 1,000, the transfer rate from bone to blood becomes dominant. For the retention in bone, the transfer rate from blood to bone surfaces has the most influence out to the endpoint of the simulation; the transfer rate from blood to the upper larger intestine contributes a lot in the later days; i.e., after day 300. The alimentary tract absorption factor (fA) influences mostly the integral of radioactivity of 95Zr in most source organs after ingestion.Health Phys. 101(6):677–692; 2011

[1]  Anja Vogler,et al.  An Introduction to Multivariate Statistical Analysis , 2004 .

[2]  W. G. Vernetson,et al.  INFLUENCES OF PARAMETER UNCERTAINTIES WITHIN THE ICRP-66 RESPIRATORY TRACT MODEL: PARTICLE CLEARANCE , 2003, Health physics.

[3]  Saltelli Andrea,et al.  Global Sensitivity Analysis: The Primer , 2008 .

[4]  J. G. Hamilton The metabolism of the fission products and the heaviest elements. , 1947, Radiology.

[5]  M. Puncher,et al.  A Monte Carlo method for calculating Bayesian uncertainties in internal dosimetry. , 2008, Radiation protection dosimetry.

[6]  H. Akaike A new look at the statistical model identification , 1974 .

[7]  K. Henrichs Concepts of ISO for the monitoring of workers for internal exposure and the present approach for the dose assessment. , 2007, Radiation protection dosimetry.

[8]  Wei Bo Li,et al.  Influence of human biokinetics of strontium on internal ingestion dose of 90Sr and absorbed dose of 89Sr to organs and metastases , 2008, Radiation and environmental biophysics.

[9]  David J. Groggel,et al.  Practical Nonparametric Statistics , 2000, Technometrics.

[10]  Stefano Tarantola,et al.  Sensitivity Analysis in Practice , 2002 .

[11]  A. Giussani A recycling systemic model for the biokinetics of molybdenum radionuclides. , 2008, The Science of the total environment.

[12]  Christoph Hoeschen,et al.  RELIABILITY OF A NEW BIOKINETIC MODEL OF ZIRCONIUM IN INTERNAL DOSIMETRY: PART I, PARAMETER UNCERTAINTY ANALYSIS , 2011, Health physics.

[13]  F Paquet,et al.  Reliability of the ICRP's dose coefficients for members of the public, II. Uncertainties in the absorption of ingested radionuclides and the effect on dose estimates. International Comission on Radiological Protection. , 2001, Radiation protection dosimetry.

[14]  R. Leggett,et al.  Reliability of the ICRP's dose coefficients for members of the public. 1. Sources of uncertainty in the biokinetic models. , 2001, Radiation protection dosimetry.

[15]  M. Bailey,et al.  Updating the ICRP human respiratory tract model. , 2007, Radiation protection dosimetry.

[16]  Wei Bo Li,et al.  Human biokinetics of strontium. Part I: Intestinal absorption rate and its impact on the dose coefficient of 90Sr after ingestion , 2006, Radiation and environmental biophysics.

[17]  J. Harrison,et al.  Reliability of the ICRP'S dose coefficients for members of the public: IV. basis of the human alimentary tract model and uncertainties in model predictions. , 2007, Radiation protection dosimetry.

[18]  L. Hammarström,et al.  Distribution of zirconium and niobium in mice. Autoradiographic study. , 2009, Acta radiologica: therapy, physics, biology.

[19]  Y. Shiraishi,et al.  Absorption and retention of 144 Ce and 95 Zr- 95 Nb in newborn, juvenile and adult rats. , 1972, Health physics.

[20]  I. Sobola,et al.  Global sensitivity indices for nonlinear mathematical models and their Monte Carlo estimates , 2001 .

[21]  Joseph A. C. Delaney Sensitivity analysis , 2018, The African Continental Free Trade Area: Economic and Distributional Effects.

[22]  M. Stein Large sample properties of simulations using latin hypercube sampling , 1987 .

[23]  R. Leggett,et al.  Reliability of the ICRP's Systemic Biokinetic Models , 1998 .

[24]  W E Bolch,et al.  Influences of parameter uncertainties within the ICRP 66 respiratory tract model: particle deposition. , 2001, Health physics.

[25]  Michael G Stabin,et al.  Uncertainties in Internal Dose Calculations for Radiopharmaceuticals , 2008, Journal of Nuclear Medicine.

[26]  R. McClellan,et al.  Relative Hazards for Inhaled 95Zr and 95Nb Particles Formed Under Various Thermal Conditions 1 , 1971, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[27]  P Fritsch,et al.  UNCERTAINTIES IN AEROSOL DEPOSITION WITHIN THE RESPIRATORY TRACT USING THE ICRP 66 MODEL: A STUDY IN WORKERS , 2006, Health physics.

[28]  H. Doerfel,et al.  Uncertainty analysis of the urinary excretion of plutonium. , 2003, Radiation protection dosimetry.

[29]  Richard J. Beckman,et al.  A Comparison of Three Methods for Selecting Values of Input Variables in the Analysis of Output From a Computer Code , 2000, Technometrics.

[30]  C. R. Fletcher The radiological hazards of zirconium-95 and niobium-95. , 1969, Health physics.

[31]  Ronald L. Iman,et al.  FORTRAN 77 program and user's guide for the calculation of partial correlation and standardized regression coefficients , 1985 .

[32]  J. Mealey Turn-over of Carrier-free Zirconium-89 in Man , 1957, Nature.

[33]  William H. Press,et al.  Numerical recipes in C , 2002 .

[34]  R. Leggett Reliability of the ICRP's dose coefficients for members of the public. III. Plutonium as a case study of uncertainties in the systemic biokinetics of radionuclides. , 2003, Radiation protection dosimetry.

[35]  R. Iman,et al.  A distribution-free approach to inducing rank correlation among input variables , 1982 .

[36]  Icrp Age-dependent doses to members of the public from intake of radionuclides: Part 4 Inhalation dose coefficients , 1995, Annals of the ICRP.

[37]  A Iulian Apostoaei,et al.  UNCERTAINTIES IN DOSE COEFFICIENTS FROM INGESTION OF 131I, 137Cs, AND 90Sr , 2004, Health physics.

[38]  Age-dependent doses to members of the public from intake of radionuclides: Part 2. Ingestion dose coefficients. A report of a Task Group of Committee 2 of the International Commission on Radiological Protection. , 1993, Annals of the ICRP.

[39]  Lawrence H. Schwartz,et al.  Imaging Surrogates of Tumor Response to Therapy: Anatomic and Functional Biomarkers* , 2009, Journal of Nuclear Medicine.

[40]  Wei Bo Li,et al.  Human biokinetics of strontium—part II: Final data evaluation of intestinal absorption and urinary excretion of strontium in human subjects after stable tracer administration , 2006, Radiation and environmental biophysics.

[41]  Jon C. Helton,et al.  Latin Hypercube Sampling and the Propagation of Uncertainty in Analyses of Complex Systems , 2002 .

[42]  J. Marsh,et al.  Sensitivity Analysis of the Weighted Equivalent Lung Dose Per Unit Exposure from Radon Progeny , 2000 .

[43]  Ronald L. Iman,et al.  A FORTRAN-77 PROGRAM AND USER'S GUIDE FOR THE GENERATION OF LATIN HYPERCUBE AND RANDOM SAMPLES FOR USE WITH COMPUTER MODELS , 1984 .

[44]  J S Evans,et al.  The effect of neglecting correlations when propagating uncertainty and estimating the population distribution of risk. , 1992, Risk analysis : an official publication of the Society for Risk Analysis.

[45]  Xiaobo Zhou,et al.  Global Sensitivity Analysis , 2017, Encyclopedia of GIS.

[46]  P. Schramel,et al.  VALIDATING AN IMPORTANT ASPECT OF THE NEW ICRP BIOKINETIC MODEL OF THORIUM , 2005, Health physics.

[47]  J. Harrison,et al.  UNCERTAINTY ANALYSIS OF DOSES FROM INHALATION OF DEPLETED URANIUM , 2008, Health physics.

[48]  C Hoeschen,et al.  Uncertainty and sensitivity analysis of biokinetic models for radiopharmaceuticals used in nuclear medicine. , 2010, Radiation protection dosimetry.

[49]  Wei Bo Li,et al.  Human biokinetic data and a new compartmental model of zirconium--a tracer study with enriched stable isotopes. , 2011, The Science of the total environment.

[50]  J. Couper Sensitivity and Uncertainty Analysis , 2003 .

[51]  Max Henrion,et al.  Uncertainty: A Guide to Dealing with Uncertainty in Quantitative Risk and Policy Analysis , 1990 .

[52]  D. De Bartolo,et al.  Kinetics of systemic ruthenium in human blood using a stable tracer. , 2001, Journal of radiological protection : official journal of the Society for Radiological Protection.

[53]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[54]  Richard W. Leggett,et al.  A reliability index for models , 1981 .

[55]  James H. Lambert,et al.  When and How Can You Specify a Probability Distribution When You Don't Know Much?1.: Organized by the U.S. Environmental Protection Agency and the University of Virginia, April 18-20, 1993, Charlottesville, Virginia , 1994 .