Vibration control using ATMD and site measurements on the Shanghai World Financial Center Tower

SUMMARY The Shanghai World Financial Center Tower is the tallest landmark building in mainland China, with a height of 492 m. In order to mitigate wind-induced vibration, a set of two identical damping devices was installed at the 90th floor. The damping devices are active tuned mass dampers: under wind loading, the active control feature is enabled, while the active control feature becomes disabled under earthquake conditions, and the damping devices function as passive tuned mass dampers. The dynamic parameters of the damping devices, structural analysis results and field measurement results under different vibration scenarios are presented in this paper. The analysis and field measurement results show that the damping devices performed well and had the following characteristics: they increased the damping ratio up to eight times in field measurements and reduced the wind acceleration response up to 60% when wind speed is below the designed value in the analysis. Copyright © 2012 John Wiley & Sons, Ltd.

[1]  森光 康夫 地上オイルパイプラインの地震応答(Earthquake Engineering and Structural Dynamics Vol.3 1975) , 1976 .

[2]  Hyun-Su Kim,et al.  Fuzzy hybrid control of a wind-excited tall building , 2010 .

[3]  Gary C. Hart,et al.  The Structural Design of Tall Buildings , 1992 .

[4]  Yukio Tamura,et al.  Damping Evaluation Using Full-Scale Data of Buildings in Japan , 2003 .

[5]  Kenny C. S Kwok,et al.  Active control of along wind response of tall building using a fuzzy controller , 2001 .

[6]  Michael Willford,et al.  Damping in tall buildings – uncertainties and solutions , 2008 .

[7]  Yun Zou,et al.  STUDY ON PERFORMANCE-BASED SEISMIC DESIGN OF SHANGHAI WORLD FINANCIAL CENTER TOWER , 2009 .

[8]  Izuru Takewaki,et al.  High-performance control of wind-induced vibration of high-rise building via innovative high-hardness rubber damper , 2009 .

[9]  Khaldoon A. Bani-Hani,et al.  Vibration control of wind‐induced response of tall buildings with an active tuned mass damper using neural networks , 2007 .

[10]  Zahraei Seyed Mahdi,et al.  SEMI-ACTIVE CONTROL OF THE WIND-EXCITED BENCHMARK TALL BUILDING USING A FUZZY CONTROLLER , 2009 .

[11]  W. H. Melbourne,et al.  Accelerations and comfort criteria for buildings undergoing complex motions , 1992 .

[12]  Takafumi Fujita,et al.  Response control performance of a hybrid mass damper applied to a tall building , 2001 .

[13]  Kazuo Tamura,et al.  Vibration control characteristics of a hybrid mass damper system installed in tall buildings , 2001 .

[14]  Nong Zhang,et al.  Field measurements of amplitude‐dependent damping in a 79‐storey tall building and its efects on the structural dynamic responses , 2002 .

[15]  Wensheng Lu,et al.  Shaking table model test on Shanghai World Financial Center Tower , 2007 .

[16]  Michael Willford,et al.  The damped outrigger concept for tall buildings , 2007 .

[17]  Åshild Næss,et al.  Earthquake and tsunami in Santa Cruz , 2015 .

[18]  Young-Moon Kim,et al.  Wind-induced excitation control of a tall building with tuned mass dampers , 2008 .

[19]  Fujun Peng,et al.  An experimental study of active control of wind-induced vibration of super-tall buildings , 2002 .

[20]  B. F. Spencer,et al.  Structural Control and Health Monitoring: Editorial , 2005 .

[21]  Gary C. Hart,et al.  The structural design of tall and special buildings , 2005 .