Complex Master-Slave for long axial range swept-source optical coherence tomography

Using Complex Master-Slave Interferometry, we demonstrate extended axial range optical coherence tomography for two commercially available swept sources, well beyond the limit imposed by their k-clocks. This is achieved without k-domain re-sampling and without engaging any additional Mach-Zehnder interferometer providing a k-clock signal to the digitizer. An axial imaging range exceeding 17 mm with an attenuation of less than 30 dB is reported using two commercially available swept sources operating at 1050 nm and a 100 kHz repetition rate. This procedure has more than trebled the range achievable using the k-clock signal provided by the manufacturers. An analysis is presented on the impact that the digitization has on the axial range and resolution of the system. © 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

[1]  Joseph A. Izatt,et al.  Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revival , 2012, Biomedical optics express.

[2]  Ruikang K. Wang,et al.  Wide field and highly sensitive angiography based on optical coherence tomography with akinetic swept source. , 2017, Biomedical optics express.

[3]  J. Fujimoto,et al.  Cubic meter volume optical coherence tomography. , 2016, Optica.

[4]  Adrian Bradu,et al.  Master/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography. , 2016, Biomedical optics express.

[5]  Joseph A. Izatt,et al.  Theory of Optical Coherence Tomography , 2008 .

[6]  Adrian Bradu,et al.  Gabor fusion master slave optical coherence tomography. , 2017, Biomedical optics express.

[7]  Daniel X Hammer,et al.  Real-time processing for Fourier domain optical coherence tomography using a field programmable gate array. , 2008, The Review of scientific instruments.

[8]  Christoph K. Hitzenberger,et al.  Beyond backscattering: optical neuroimaging by BRAD , 2017, Biomedical optics express.

[9]  Adrian Bradu,et al.  Master-slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence tomography. , 2013, Optics express.

[10]  Anthony Kuo,et al.  Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revival. , 2012, Optics letters.

[11]  A. Bradu,et al.  Demonstration of tolerance to dispersion of master/slave interferometry. , 2015, Optics express.

[12]  Adrian Bradu,et al.  Complex master slave interferometry. , 2016, Optics express.

[13]  Adrian Bradu,et al.  Real-time resampling in Fourier domain optical coherence tomography using a graphics processing unit. , 2010, Journal of biomedical optics.

[14]  Zhihua Ding,et al.  High-resolution optical coherence tomography over a large depth range with an axicon lens. , 2002, Optics letters.

[15]  Hiroshi Mashimo,et al.  Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source. , 2017, Optics letters.

[16]  R. Leitgeb,et al.  Extended focus depth for Fourier domain optical coherence microscopy. , 2006, Optics letters.

[17]  Y. Yasuno,et al.  Full-range, high-speed, high-resolution 1 microm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. , 2008, Optics express.

[18]  Panomsak Meemon,et al.  Gabor-based fusion technique for Optical Coherence Microscopy. , 2010, Optics express.

[19]  Joachim Hornegger,et al.  Depth-encoded all-fiber swept source polarization sensitive OCT. , 2014, Biomedical optics express.

[20]  Adrian Bradu,et al.  Novel software package to facilitate operation of any spectral (Fourier) OCT system , 2017, European Conference on Biomedical Optics.

[21]  Ruikang K. Wang,et al.  Long ranging swept-source optical coherence tomography-based angiography outperforms its spectral-domain counterpart in imaging human skin microcirculations , 2017, Journal of biomedical optics.