A Velocity-Dependent Model for Needle Insertion in Soft Tissue

Models that predict the soft tissue deformation caused by needle insertion could improve the accuracy of procedures such as brachytherapy and needle biopsy. Prior work on needle insertion modeling has focused on static deformation; the experiments presented here show that dynamic effects such as relaxation are important. An experimental setup is described for recording and measuring the deformation that occurs with needle insertion into a soft tissue phantom. Analysis of the collected data demonstrates the time- and velocity-dependent nature of the deformation. Deformation during insertion is shown to be well represented using a velocity-dependent force function with a linear elastic finite element model. The model's accuracy is limited to the period during needle motion, indicating that a viscoelastic tissue model may be required to capture tissue relaxation after the needle stops.

[1]  P. Gorman,et al.  A prototype haptic lumbar puncture simulator. , 2000, Studies in health technology and informatics.

[2]  Jean Ponce,et al.  Computer Vision: A Modern Approach , 2002 .

[3]  Zhe Chen,et al.  Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds. , 2000, Medical physics.

[4]  P. Roberson,et al.  Source placement error for permanent implant of the prostate. , 1997, Medical physics.

[5]  Y. Fung,et al.  Biomechanics: Mechanical Properties of Living Tissues , 1981 .

[6]  Kenneth Y. Goldberg,et al.  Needle insertion and radioactive seed implantation in human tissues: simulation and sensitivity analysis , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).

[7]  Robert D. Howe,et al.  The Effects of Testing Environment on the Viscoelastic Properties of Soft Tissues , 2004, ISMS.

[8]  Stephane Cotin,et al.  Truth cube: Establishing physical standards for soft tissue simulation , 2003, Medical Image Anal..

[9]  Stéphane Cotin,et al.  Truth Cube: Establishing Physical Standards for Real Time Soft Tissue Simulation , 2001 .

[10]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[11]  Jianhua Xuan,et al.  3-D Model Supported Prostrate Biopsy Simulation and Evaluation , 1998, MICCAI.

[12]  Septimiu E. Salcudean,et al.  Needle insertion modelling and simulation , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[13]  F Tendick,et al.  Measuring in vivo animal soft tissue properties for haptic modeling in surgical simulation. , 2001, Studies in health technology and informatics.

[14]  William M. Wells,et al.  Medical Image Computing and Computer-Assisted Intervention — MICCAI’98 , 1998, Lecture Notes in Computer Science.

[15]  Septimiu E. Salcudean,et al.  Needle insertion modeling and simulation , 2003, IEEE Trans. Robotics Autom..

[16]  Kenneth G. A. Gilhuijs,et al.  Displacement of breast tissue and needle deviations during stereotactic procedures. , 2001 .