Compensation of current measurement error in half-bridge PWM inverter for linear compressor

This paper proposes a novel compensation algorithm of current measurement error for single-phase linear compressor in home appliances. Current measurement error which may be problem, when use the DC link divided into two capacitors in half-bridge inverter, causes the unbalanced DC link voltage. In order to compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When the output current of the half-bridge inverter includes offset error, the d-axis current has a ripple of fundamental frequency. By using a PR(Proportional-Resonant) controller, first harmonic can be removed and can be compensated measurement error. The proposed compensation method can be easily implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through simulations.

[1]  Jong-Woo Choi,et al.  Digital PLL control for single-phase photovoltaic system , 2004 .

[2]  Sung-Jun Park,et al.  A novel high-performance voltage regulator for single-phase AC sources , 2001, IEEE Trans. Ind. Electron..

[3]  Ali Emadi,et al.  A new reduced parts on-line single-phase UPS system , 2003, IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468).

[4]  Tae-Uk Jung,et al.  DC voltage balancing control of half-bridge PWM inverter for linear compressor , 2012, 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[5]  Jiabin Wang,et al.  A Learning Feed-Forward Current Controller for Linear Reciprocating Vapor Compressors , 2011, IEEE Transactions on Industrial Electronics.

[6]  S.M. Silva,et al.  PLL structures for utility connected systems , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[7]  Jong-Woo Choi,et al.  Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters , 2014 .

[8]  Jang-Mok Kim,et al.  Reduction of current ripples due to current measurement errors in a Doubly Fed Induction Generator , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[9]  Hong-Hee Lee,et al.  A Novel Strategy of Efficiency Control for a Linear Compressor System Driven by a PWM Inverter , 2008, IEEE Transactions on Industrial Electronics.

[10]  Kyo-Beum Lee,et al.  A 2 nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller , 2013 .

[11]  M. Liserre,et al.  A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[12]  Seung-Ki Sul,et al.  Analysis and compensation of current measurement error in vector controlled AC motor drives , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[13]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady-state error , 2003 .

[14]  Seung-Ki Sul,et al.  Current measurement issues in sensorless control algorithm using high frequency signal injection method , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[15]  John E. Quaicoe,et al.  Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters , 1996 .

[16]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[17]  Dong-Choon Lee,et al.  Identification of DC-Link Capacitance for Single-Phase AC/DC PWM Converters , 2010 .

[18]  Toshiharu Ninomiya,et al.  A study of the high performance single-phase UPS , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).