In vivo kinematic measurement during laparoscopic cholecystectomy

BackgroundDespite the rapid development of computer-assisted surgery, studies on kinematic measurement for surgical innovation are rare. This study describes a system for kinematic measurement in real operating theater environments. Six laparoscopic cholecystectomies were recorded and analyzed. In addition to, a demonstration of the feasibility of the method, basis data for the development of an actuated laparoscopic camera holder are evaluated.MethodsThe positions of four receivers were recorded by an electromagnetic motion acquisition system. Analysis of the data was performed postoperatively with matlab. Parameters, such as coordinates, velocities, angles angular velocities, worspaces in typical phases of an operation, and subareas of the coordinate ranges were computed.ResultsThe workspace during the operation in situ before (II) and after (V) removal of the gallbladder at the upper camera end was as follows: (X, Y, Z; given in cm):II: 65.5·42.7·27.3 (subarea 90%=8.3·14.0·6.3);V:57.4·33.3·26.2, (90%=103·16.5·7.9). Workspaces at the lower camere end were smaller:II: 14.8·9.7·15.4; (90%=3.5·3.1·4.3). During these operation phases, velocities up to 82.9 cm/s were documented. Most of the measured velocities were much smaller. The camera-tiltangles in left/right (αx) and head/feet (αy) direction were as follows: αx:−69°t to +69° and αy:−74° to +48°.ConclusionThis study demonstrates the feasibility of real-time kinematic measurement in the operation environment. The information might be of future value not only as basis data for the development of camera holders, but also for further investigations on robotics, ergonomics, and simulation.

[1]  R. Riener,et al.  Acquisition of arm and instrument movements during laparoscopic interventions , 2003, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[2]  Volodymyr V. Kindratenko A Comparison of the Accuracy of an Electromagnetic and a Hybrid Ultrasound-Inertia Position Tracking System , 2001, Presence: Teleoperators & Virtual Environments.

[3]  A. Cuschieri,et al.  Rocker handle for endoscopic needle drivers. Technical and ergonomic evaluation by infrared motion analysis system. , 1999, Surgical endoscopy.

[4]  Shahram Payandeh,et al.  On defining metrics for assessing laparoscopic surgical skills in a virtual training environment. , 2002, Studies in health technology and informatics.

[5]  T. G. Frank,et al.  Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing , 2001, Surgical Endoscopy.

[6]  L. MacKenzie,et al.  Hierarchical decomposition of laparoscopic surgery: a human factors approach to investigating the operating room environment , 2001, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[7]  A. J. Hodgson,et al.  Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery , 2009, Surgical Endoscopy.