Modeling and control of multi-terminal HVDC with offshore wind farm integration and DC chopper based protection strategies

Multi-Terminal HVDC based on three-level neutral-clamped voltage source converters (VSC) is an ideal approach for the integration of DFIG wind farms to the power grid. However, dc-link faults and ac faults are major concerns for the safety and consistency of VSC-HVDC system. This paper demonstrates methods employing both full bridge and half bridge DC-DC converters for the fast clearance and protection of dc and ac ground faults respectively. In addition, control strategies incorporating decoupling control and feed-forward compensation on both grid side and wind farm side VSCs are also presented. Normal operations are observed to examine the performance of the MT-HVDC system, and also dc-link fault and three-phase ground fault at inverter side are simulated to verify the effectiveness of the approach employing DC-DC converters to suppress dc current overshoot in case of dc-link fault and mitigate dc voltage overshoot during three-phase ac ground fault. This proposed MT-HVDC transmission system and the fault-ride through capabilities provided by the dc choppers is validated by the simulation studies using detailed Matlab/Simulink model for normal operation, dc and ac ground faults.

[1]  Dragan Jovcic,et al.  Evaluation of Semiconductor Based Methods for Fault Isolation on High Voltage DC Grids , 2013, IEEE Transactions on Smart Grid.

[2]  Raul Rabinovici,et al.  Distribution Generation Case Study: Electric Wind Farm with Doubly Fed Induction Generators , 2006, 2006 IEEE 24th Convention of Electrical & Electronics Engineers in Israel.

[3]  Hairong Chen Research on the control strategy of VSC based HVDC system supplying passive network , 2009, 2009 IEEE Power & Energy Society General Meeting.

[4]  Lu Zhang,et al.  LCL VSC Converter for High-Power Applications , 2013, IEEE Transactions on Power Delivery.

[5]  V.G. Agelidis,et al.  VSC-Based HVDC Power Transmission Systems: An Overview , 2009, IEEE Transactions on Power Electronics.

[6]  Liangzhong Yao,et al.  Grid Integration of Large DFIG-Based Wind Farms Using VSC Transmission , 2007, IEEE Transactions on Power Systems.

[7]  H. Polinder,et al.  General Model for Representing Variable-Speed Wind Turbines in Power System Dynamics Simulations , 2002, IEEE Power Engineering Review.

[8]  R. Takahashi,et al.  Control strategy for HVDC interconnected DC-based offshore wind farm , 2009, 2009 International Conference on Electrical Machines and Systems.

[9]  L. Weimers HVDC Light: A New Technology for a Better Environment , 1998, IEEE Power Engineering Review.

[10]  Boon-Teck Ooi,et al.  DC overvoltage control during loss of converter in multiterminal voltage-source converter-based HVDC (M-VSC-HVDC) , 2003 .

[11]  Lingling Fan,et al.  Modeling and control of DFIG-based large offshore wind farm with HVDC-link integration , 2009, 41st North American Power Symposium.

[12]  Christopher Smith,et al.  DC transmission and distribution system for a large offshore wind farm , 2010 .

[13]  Jae-Do Park,et al.  VSC-HVDC system protection: A review of current methods , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[14]  Lingling Fan,et al.  Modeling and simulation of multi-terminal HVDC for wind power delivery , 2012, 2012 IEEE Power Electronics and Machines in Wind Applications.

[15]  Bian Song-jiang MODELING AND SIMULATION OF AC EXCITED VSCF IN WIND POWER SYSTEMS , 2005 .

[16]  Ran Li System Simulation of a Doubly Fed Induction Generator Ride-through Control for Symmetrical Grid Fault , 2006 .

[17]  Zhe Chen,et al.  Design of Protective Inductors for HVDC Transmission Line Within DC Grid Offshore Wind Farms , 2013, IEEE Transactions on Power Delivery.

[18]  Stefan Lundberg,et al.  System efficiency of a DC/DC converter‐based wind farm , 2008 .

[19]  Zheng Xu,et al.  Study of protection strategy for VSC based HVDC system , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[20]  B. T. Ooi,et al.  Optimal Acquisition and Aggregation of Offshore Wind Power by Multiterminal Voltage-Source HVdc , 2002, IEEE Power Engineering Review.

[21]  S. J. Finney,et al.  New Breed of Network Fault-Tolerant Voltage-Source-Converter HVDC Transmission System , 2013, IEEE Transactions on Power Systems.

[22]  O. Gomis-Bellmunt,et al.  Control of a Wind Farm Based on Synchronous Generators With a Central HVDC-VSC Converter , 2011, IEEE Transactions on Power Systems.

[23]  O. Anaya-Lara,et al.  Analysis of wide area integration of dispersed wind farms using multiple VSC-HVDC links , 2008, 2008 13th International Power Electronics and Motion Control Conference.

[24]  R. Torres-Olguin,et al.  Offshore Wind Farm Grid Integration by VSC Technology With LCC-Based HVDC Transmission , 2012, IEEE Transactions on Sustainable Energy.

[25]  Boon-Teck Ooi,et al.  Locating and Isolating DC Faults in Multi-Terminal DC Systems , 2007, IEEE Transactions on Power Delivery.