Early detection and monitoring of chronic wounds using low-cost, omniphobic paper-based smart bandages.

The growing socio-economic burden of chronic skin wounds requires the development of new automated and non-invasive analytical systems capable of wirelessly monitoring wound status. This work describes the low-cost fabrication of single-use, omniphobic paper-based smart bandages (OPSBs) designed to monitor the status of open chronic wounds and to detect the formation of pressure ulcers. OPSBs are lightweight, flexible, breathable, easy to apply, and disposable by burning. A reusable wearable potentiostat was fabricated to interface with the OPSB simply by attaching it to the back of the bandage. The wearable potentiostat and the OPSB can be used to simultaneously quantify pH and uric acid levels at the wound site, and wirelessly report wound status to the user or medical personnel. Additionally, the wearable potentiostat and the OPSBs can be used to detect, in an in-vivo mouse model, the formation of pressure ulcers even before the pressure-induced tissue damage becomes visible, using impedance spectroscopy. Our results demonstrate the feasibility of using inexpensive single-use OPSBs and a reusable, wearable potentiostat that can be easily sterilized and attached to a new OPSB during the dressing change, to provide long term wound progression data to guide treatment decisions.

[1]  Joachim Dissemond,et al.  Influence of pH on wound-healing: a new perspective for wound-therapy? , 2007, Archives of Dermatological Research.

[2]  Ivana Murković Steinberg,et al.  Smart bandage with wireless connectivity for optical monitoring of pH , 2017 .

[3]  M. Lisboa,et al.  Development and validation of the experimental wound assessment tool (EWAT) for pressure ulcer in laboratory animals. , 2018, Journal of pharmacological and toxicological methods.

[4]  M. T. Fernández-Abedul,et al.  Electroanalytical devices with pins and thread. , 2016, Lab on a chip.

[5]  Joseph Thomas Velardo,et al.  Histochemistry, Theoretical and Applied , 1960, The Yale Journal of Biology and Medicine.

[6]  Tim R. Dargaville,et al.  Sensors and imaging for wound healing: a review. , 2013, Biosensors & bioelectronics.

[7]  Nicolas H Voelcker,et al.  Applications of modern sensors and wireless technology in effective wound management. , 2014, Journal of biomedical materials research. Part B, Applied biomaterials.

[8]  George M Whitesides,et al.  Rapid fabrication of pressure-driven open-channel microfluidic devices in omniphobic R(F) paper. , 2013, Lab on a chip.

[9]  Lili Liu,et al.  A facile electrochemical uricase biosensor designed from gold/amino acid nanocomposites , 2013 .

[10]  Mayank Joshi,et al.  Laser patterned carbon–polyethylene mesh electrodes for wound diagnostics , 2014 .

[11]  Babak Ziaie,et al.  A low-cost flexible pH sensor array for wound assessment , 2016 .

[12]  Alex Nemiroski,et al.  Universal mobile electrochemical detector designed for use in resource-limited applications , 2014, Proceedings of the National Academy of Sciences.

[13]  Jacques Jossinet,et al.  Remote Wound Monitoring of Chronic Ulcers , 2010, IEEE Transactions on Information Technology in Biomedicine.

[14]  Duncan Sharp,et al.  Integrated urate sensors for detecting wound infection , 2008 .

[15]  Jayoung Kim,et al.  Smart bandage with wireless connectivity for uric acid biosensing as an indicator of wound status , 2015 .

[16]  Zhengdong Sun,et al.  Immobilization of uricase on ZnO nanorods for a reagentless uric acid biosensor , 2004 .

[17]  Claudio Cortese,et al.  Uricase biosensor based on a screen-printed electrode modified with Prussian blue for detection of uric acid in human blood serum , 2013 .

[18]  K. Maniura‐Weber,et al.  Simultaneous detection of pH value and glucose concentrations for wound monitoring applications. , 2017, Biosensors & bioelectronics.

[19]  O. Korostynska,et al.  Review Paper: Materials and Techniques for In Vivo pH Monitoring , 2008, IEEE Sensors Journal.

[20]  Scott J Hollister,et al.  Non-invasive monitoring of tissue scaffold degradation using ultrasound elasticity imaging. , 2008, Acta biomaterialia.

[21]  P. Franks,et al.  The burden of chronic wounds in the UK. , 2008, Nursing times.

[22]  Elizabeth A. Ayello,et al.  A new era of pressure ulcer accountability in acute care. , 2008, Advances in skin & wound care.

[23]  S. Forsythe,et al.  Carbon fibre composites: integrated electrochemical sensors for wound management. , 2008, Journal of biochemistry.

[24]  Alar Ainla,et al.  Integrating Electronics and Microfluidics on Paper , 2016, Advanced materials.

[25]  Babak Ziaie,et al.  Wireless flexible smart bandage for continuous monitoring of wound oxygenation , 2014, 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings.

[26]  A. Jenkins,et al.  A thin film detection/response system for pathogenic bacteria. , 2010, Journal of the American Chemical Society.

[27]  C. Weder,et al.  Electrical conductivity and mechanical properties of polyaniline/natural rubber composite fibers , 2007 .

[28]  R. V. Martinez,et al.  Self‐Powered, Paper‐Based Electrochemical Devices for Sensitive Point‐of‐Care Testing , 2017 .

[29]  Vivian K. Wong,et al.  Skin Blood Flow Response to 2-Hour Repositioning in Long-term Care Residents: A Pilot Study , 2011, Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society.

[30]  Kun Duan,et al.  Multimodal Sensor System for Pressure Ulcer Wound Assessment and Care , 2018, IEEE Transactions on Industrial Informatics.

[31]  Yuhao Liu,et al.  Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring. , 2017, ACS nano.

[32]  P. Erden,et al.  A review of enzymatic uric acid biosensors based on amperometric detection. , 2013, Talanta.

[33]  M. Landthaler,et al.  Luminescent Dual Sensors Reveal Extracellular pH-Gradients and Hypoxia on Chronic Wounds That Disrupt Epidermal Repair , 2014, Theranostics.

[34]  E. Jude,et al.  The molecular biology of chronic wounds and delayed healing in diabetes , 2006, Diabetic medicine : a journal of the British Diabetic Association.

[35]  Atif Shamim,et al.  Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds , 2016, Scientific Reports.

[36]  Mu Chiao,et al.  A flexible pH sensor based on the iridium oxide sensing film , 2011 .

[37]  P. Connolly,et al.  Developing a Real Time Sensing System to Monitor Bacteria in Wound Dressings , 2012, Biosensors.

[38]  Babak Ziaie,et al.  Highly Stretchable Potentiometric pH Sensor Fabricated via Laser Carbonization and Machining of Carbon-Polyaniline Composite. , 2017, ACS applied materials & interfaces.

[39]  P. Kurzweil,et al.  Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook , 2009, Sensors.

[40]  Reginald Birngruber,et al.  Non-invasive transdermal two-dimensional mapping of cutaneous oxygenation with a rapid-drying liquid bandage. , 2014, Biomedical optics express.

[41]  Mark S Granick,et al.  Wound Dressings and Comparative Effectiveness Data. , 2014, Advances in wound care.

[42]  R. Rahimi,et al.  Flexible Sensors for Chronic Wound Management , 2014, IEEE Reviews in Biomedical Engineering.

[43]  Gojiro Nakagami,et al.  Ultrasound Assessment of Deep Tissue Injury in Pressure Ulcers: Possible Prediction of Pressure Ulcer Progression , 2009, Plastic and reconstructive surgery.

[44]  James Davis,et al.  Wound Diagnostics: Deploying Electroanalytical Strategies for Point of Care Sensors and Smart Dressings. , 2017 .

[45]  Dan L. Bader,et al.  A Review of the Role of the Partial Pressure of Carbon Dioxide in Mechanically Loaded Tissues: The Canary in the Cage Singing in Tune with the Pressure Ulcer Mantra , 2014, Annals of Biomedical Engineering.

[46]  J. Windmiller,et al.  Bandage-Based Wearable Potentiometric Sensor for Monitoring Wound pH , 2014 .

[47]  T. K. Hunt,et al.  Human skin wounds: A major and snowballing threat to public health and the economy , 2009, Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society.

[48]  S. Roth,et al.  Transparent and flexible carbon nanotube/polypyrrole and carbon nanotube/polyaniline pH sensors , 2006 .

[49]  Patricia Connolly,et al.  Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study. , 2007, International journal of surgery.

[50]  D. Finlay Connected Health Approaches to Wound Monitoring , 2016 .

[51]  Jill Cundell,et al.  New Developments in Smart Bandage Technologies for Wound Diagnostics , 2016, Advanced materials.

[52]  Zee Upton,et al.  Uric Acid and Xanthine Oxidoreductase in Wound Healing , 2014, Current Rheumatology Reports.

[53]  Jung Woo Lee,et al.  Multifunctional Skin‐Like Electronics for Quantitative, Clinical Monitoring of Cutaneous Wound Healing , 2014, Advanced healthcare materials.

[54]  S. Falzgraf,et al.  Wound care in the geriatric client , 2009, Clinical interventions in aging.

[55]  Vivek Subramanian,et al.  Impedance sensing device enables early detection of pressure ulcers in vivo , 2015, Nature Communications.