Extracellular Vesicle Flow Cytometry Analysis and Standardization

The term extracellular vesicles (EVs) describes membranous vesicles derived from cells, ranging in diameter from 30 to 1,000 nm with the majority thought to be in the region of 100–150 nm. Due to their small diameter and complex and variable composition, conventional techniques have struggled to accurately count and phenotype EVs. Currently, EV characterization using high-resolution flow cytometry is the most promising method when compared to other currently available techniques, due to it being a high-throughput, single particle, multi-parameter analysis technique capable of analyzing a large range of particle diameters. Whilst high resolution flow cytometry promises detection of the full EV diameter range, standardization of light scattering and fluorescence data between different flow cytometers remains an problem. In this mini review, we will discuss the advances in high-resolution flow cytometry development and future direction of EV scatter and fluorescence standardization. Standardization and therefore reproducibility between research groups and instrumentation is lacking, hindering the validation of EVs use as diagnostic biomarkers and therapeutics.

[1]  C. Théry,et al.  Biogenesis, secretion, and intercellular interactions of exosomes and other extracellular vesicles. , 2014, Annual review of cell and developmental biology.

[2]  A. Brisson,et al.  A simple flow cytometry method improves the detection of phosphatidylserine-exposing extracellular vesicles , 2014, Journal of thrombosis and haemostasis : JTH.

[3]  A. K. Gaigalas,et al.  Quantitating Fluorescence Intensity From Fluorophore: Assignment of MESF Values , 2005, Journal of research of the National Institute of Standards and Technology.

[4]  J. Nolan,et al.  Direct fluorescent staining and analysis of proteins on microspheres using CBQCA , 2005, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[5]  M. Henderson,et al.  Enumeration of extracellular vesicles by a new improved flow cytometric method is comparable to fluorescence mode nanoparticle tracking analysis. , 2016, Nanomedicine : nanotechnology, biology, and medicine.

[6]  T. V. van Leeuwen,et al.  Refractive index determination of nanoparticles in suspension using nanoparticle tracking analysis. , 2014, Nano letters.

[7]  John P Nolan,et al.  Flow Cytometry of Extracellular Vesicles: Potential, Pitfalls, and Prospects , 2015, Current protocols in cytometry.

[8]  C. Tropea,et al.  Light Scattering from Small Particles , 2003 .

[9]  R Lacroix,et al.  Standardization of pre‐analytical variables in plasma microparticle determination: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshop , 2013, Journal of thrombosis and haemostasis : JTH.

[10]  J. Lötvall,et al.  The influence of rotor type and centrifugation time on the yield and purity of extracellular vesicles , 2014, Journal of extracellular vesicles.

[11]  M. C. Martínez,et al.  Extracellular Vesicles as Therapeutic Tools in Cardiovascular Diseases , 2014, Front. Immunol..

[12]  R A Hoffman,et al.  Evaluating fluorescence sensitivity on flow cytometers: an overview. , 1998, Cytometry.

[13]  S. Hansson,et al.  Placenta-derived extracellular vesicles: their cargo and possible functions. , 2017, Reproduction, fertility, and development.

[14]  Lili Wang,et al.  Formalization of the MESF unit of fluorescence intensity , 2004, Cytometry. Part B, Clinical cytometry.

[15]  T G van Leeuwen,et al.  Optical and non‐optical methods for detection and characterization of microparticles and exosomes , 2010, Journal of thrombosis and haemostasis : JTH.

[16]  Chris Gardiner,et al.  Measurement of refractive index by nanoparticle tracking analysis reveals heterogeneity in extracellular vesicles , 2014, Journal of extracellular vesicles.

[17]  M. V. van Gemert,et al.  Single vs. swarm detection of microparticles and exosomes by flow cytometry , 2012, Journal of thrombosis and haemostasis : JTH.

[18]  Lili Wang,et al.  Standardization, Calibration, and Control in Flow Cytometry , 2017, Current protocols in cytometry.

[19]  M. Krumrey,et al.  Innovation in detection of microparticles and exosomes , 2013, Journal of thrombosis and haemostasis : JTH.

[20]  R. Szatanek,et al.  Isolation of extracellular vesicles: Determining the correct approach (Review) , 2015, International journal of molecular medicine.

[21]  J H Jett,et al.  Detection of single molecules of phycoerythrin in hydrodynamically focused flows by laser-induced fluorescence. , 1987, Analytical chemistry.

[22]  Willem Stoorvogel,et al.  Fluorescent labeling of nano-sized vesicles released by cells and subsequent quantitative and qualitative analysis by high-resolution flow cytometry , 2012, Nature Protocols.

[23]  Joshua N Leonard,et al.  Therapeutic applications of extracellular vesicles: clinical promise and open questions. , 2015, Annual review of pharmacology and toxicology.

[24]  J C Wood,et al.  Fundamental flow cytometer properties governing sensitivity and resolution. , 1998, Cytometry.

[25]  H B Steen,et al.  Noise, sensitivity, and resolution of flow cytometers. , 1992, Cytometry.

[26]  G. van den Engh,et al.  Prerequisites for the analysis and sorting of extracellular vesicle subpopulations by high‐resolution flow cytometry , 2016, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[27]  Simon C Watkins,et al.  Current Protocols In Cytometry , 1997 .

[28]  Xiaomei Yan,et al.  Light-Scattering Detection below the Level of Single Fluorescent Molecules for High-Resolution Characterization of Functional Nanoparticles , 2014, ACS nano.

[29]  Valeri P. Maltsev,et al.  Super‐resolved calibration‐free flow cytometric characterization of platelets and cell‐derived microparticles in platelet‐rich plasma , 2016, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[30]  V. Maltsev Scanning flow cytometry for individual particle analysis , 2000 .

[31]  Paul Harrison,et al.  Classification, Functions, and Clinical Relevance of Extracellular Vesicles , 2012, Pharmacological Reviews.

[32]  A. Falus,et al.  Emerging role of extracellular vesicles in inflammatory diseases , 2014, Nature Reviews Rheumatology.

[33]  I. Vorobjev,et al.  Circulating microparticles: square the circle , 2013, BMC Cell Biology.

[34]  R Lacroix,et al.  Standardization of platelet‐derived microparticle enumeration by flow cytometry with calibrated beads: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshop , 2010, Journal of thrombosis and haemostasis : JTH.

[35]  H M Shapiro,et al.  Detection and discrimination of individual viruses by flow cytometry. , 1979, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[36]  John P. Nolan,et al.  High sensitivity flow cytometry of membrane vesicles , 2016, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[37]  R. Nieuwland,et al.  Single-step isolation of extracellular vesicles by size-exclusion chromatography , 2014, Journal of extracellular vesicles.

[38]  Ger J.A. Arkesteijn,et al.  Quantitative and qualitative flow cytometric analysis of nanosized cell-derived membrane vesicles , 2011, Nanomedicine: Nanotechnology, Biology and Medicine.

[39]  M. Krumrey,et al.  Towards traceable size determination of extracellular vesicles , 2014, Journal of extracellular vesicles.

[40]  H. Shapiro Practical Flow Cytometry: Shapiro/Flow Cytometry 4e , 2005 .

[41]  Elmar L. Gool,et al.  Recent developments in the nomenclature, presence, isolation, detection and clinical impact of extracellular vesicles , 2016, Journal of thrombosis and haemostasis : JTH.

[42]  A. Hill,et al.  Techniques used for the isolation and characterization of extracellular vesicles: results of a worldwide survey , 2016, Journal of extracellular vesicles.

[43]  W. Chandler Microparticle counts in platelet-rich and platelet-free plasma, effect of centrifugation and sample-processing protocols , 2012, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[44]  R. Hoffman,et al.  Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity. , 1998, Cytometry.

[45]  Edward Early,et al.  Quantitating Fluorescence Intensity from Fluorophore: The Definition of MESF Assignment , 2002, Journal of research of the National Institute of Standards and Technology.

[46]  Alain Brisson,et al.  Fluorescence triggering: A general strategy for enumerating and phenotyping extracellular vesicles by flow cytometry , 2016, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[47]  Chris Gardiner,et al.  Extracellular vesicle sizing and enumeration by nanoparticle tracking analysis , 2013, Journal of extracellular vesicles.

[48]  R. Nieuwland,et al.  Biological reference materials for extracellular vesicle studies , 2017, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[49]  Shannon McWeeney,et al.  MIFlowCyt: The minimum information about a flow cytometry experiment , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[50]  John P Nolan,et al.  A trigger channel threshold artifact in nanoparticle analysis , 2013, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[51]  M. Araúzo-Bravo,et al.  Inflammaging and Frailty Status Do Not Result in an Increased Extracellular Vesicle Concentration in Circulation , 2016, International journal of molecular sciences.

[52]  Virginia Claudio,et al.  Methods for the physical characterization and quantification of extracellular vesicles in biological samples. , 2017, Biochimica et biophysica acta. General subjects.