All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples.

While ion to electron transducing layers for the fabrication of potentiometric membrane electrodes for the detection of cations have been well established, similar progress for the sensing of anions has not yet been realized. We report for this reason on a novel approach for the development of all-solid-state anion selective electrodes using lipophilic multiwalled carbon nanotubes (f-MWCNTs) as the inner ion to electron transducing layer. This material can be solvent cast, as it conveniently dissolves in tetrahydrofuran (THF), an important advantage to develop uniform films without the need for using surfactants that might deteriorate the performance of the electrode. Solid contact sensors for carbonate, nitrate, nitrite, and dihydrogen phosphate are fabricated and characterized, and all exhibit comparable analytical characteristics to the inner liquid electrodes. For example, the carbonate sensor exhibits a Nernstian slope of 27.2 ± 0.8 mV·dec(-1), a LOD = 2.3 μM, a response time of 1 s, a linear range of four logarithmic units, and a medium-term stability of 0.04 mV·h(-1) is obtained in a pH 8.6 buffered solution. Water layer test, reversibility, and selectivity for chloride, nitrate, and hydroxide are also reported. The excellent properties of f-MWCNTs as a transducer are contrasted to the deficient performance of poly(3-octyl-thiophene) (POT) for carbonate detection. This is evidenced both with a significant drift in the potentiometric measures as well as a pronounced sensitivity to light (either sunlight or artificial light). This latter aspect may compromise its potential for environmental in situ measurements (night/day cycles). The concentration of carbonate is determined in a river sample (Arve river, Geneva) and compared to a reference method (automatic titrator with potentiometric pH detection). The results suggest that nanostructured materials such as f-MWCNTs are an attractive platform as a general ion-to-electron transducer for anion-selective electrodes.

[1]  G. Crespo,et al.  Exhaustive thin-layer cyclic voltammetry for absolute multianalyte halide detection. , 2014, Analytical chemistry.

[2]  Andreas Stein,et al.  Ion-selective electrodes with colloid-imprinted mesoporous carbon as solid contact. , 2014, Analytical chemistry.

[3]  G. Crespo,et al.  Nitrite-Selective Electrode Based On Cobalt(II) tert-Butyl-Salophen Ionophore , 2014 .

[4]  Ernö Pretsch,et al.  Evidence for a surface confined ion-to-electron transduction reaction in solid-contact ion-selective electrodes based on poly(3-octylthiophene). , 2013, Analytical chemistry.

[5]  F. Rius,et al.  Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes. , 2013, The Analyst.

[6]  E. Bakker,et al.  Non-Severinghaus potentiometric dissolved CO2 sensor with improved characteristics. , 2013, Analytical chemistry.

[7]  J. Riu,et al.  Reduced Graphene Oxide Films as Solid Transducers in Potentiometric All-Solid-State Ion-Selective Electrodes , 2012 .

[8]  F. Rius,et al.  Nanostructured assemblies for ion-sensors: functionalization of multi-wall carbon nanotubes with benzo-18-crown-6 for Pb2+ determination , 2012 .

[9]  A. Michalska All‐Solid‐State Ion Selective and All‐Solid‐State Reference Electrodes , 2012 .

[10]  F. Rius,et al.  Paper-based ion-selective potentiometric sensors. , 2012, Analytical chemistry.

[11]  J. Riu,et al.  Potentiometric strip cell based on carbon nanotubes as transducer layer: toward low-cost decentralized measurements. , 2011, Analytical chemistry.

[12]  E. Jaworska,et al.  Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings. , 2011, Talanta.

[13]  Jordi Riu,et al.  Disposable planar reference electrode based on carbon nanotubes and polyacrylate membrane. , 2011, Analytical chemistry.

[14]  R. E. Gyurcsányi,et al.  Hyphenated FT-IR-attenuated total reflection and electrochemical impedance spectroscopy technique to study the water uptake and potential stability of polymeric solid-contact ion-selective electrodes. , 2011, Analytical chemistry.

[15]  F. Rius,et al.  An effective nanostructured assembly for ion-selective electrodes. An ionophore covalently linked to carbon nanotubes for Pb2+ determination. , 2011, Chemical communications.

[16]  J. Riu,et al.  Nanostructured materials in potentiometry , 2011, Analytical and bioanalytical chemistry.

[17]  Yu Qin,et al.  Single-piece solid-contact ion-selective electrodes with polymer–carbon nanotube composites , 2010 .

[18]  P. Ballester,et al.  Determination of choline and derivatives with a solid-contact ion-selective electrode based on octaamide cavitand and carbon nanotubes. , 2009, Biosensors & bioelectronics.

[19]  F. Rius,et al.  Solid-contact pH-selective electrode using multi-walled carbon nanotubes , 2009, Analytical and bioanalytical chemistry.

[20]  J. Riu,et al.  Ion-selective electrodes using multi-walled carbon nanotubes as ion-to-electron transducers for the detection of perchlorate. , 2009, In Analysis.

[21]  FTIR-ATR study of water uptake and diffusion through ion-selective membranes based on poly(acrylates) and silicone rubber. , 2009, Analytical chemistry.

[22]  F. Rius,et al.  Transduction mechanism of carbon nanotubes in solid-contact ion-selective electrodes. , 2009, Analytical chemistry.

[23]  Róbert E. Gyurcsányi,et al.  Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes , 2009 .

[24]  A. Bissett,et al.  A microsensor for carbonate ions suitable for microprofiling in freshwater and saline environments , 2008 .

[25]  A. Ivaska,et al.  Soluble semiconducting poly(3-octylthiophene) as a solid-contact material in all-solid-state chloride sensors , 2008 .

[26]  Ernö Pretsch,et al.  Elimination of undesirable water layers in solid-contact polymeric ion-selective electrodes. , 2008, Analytical chemistry.

[27]  F. Rius,et al.  Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers. , 2008, Analytical chemistry.

[28]  A. Ivaska,et al.  Potentiometric ion sensors. , 2008, Chemical reviews.

[29]  Yoshio Umezawa,et al.  Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report) , 2008 .

[30]  A. Stein,et al.  Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact. , 2007, Analytical chemistry.

[31]  Galina A. Khripoun,et al.  Nitrate-Selective Solid Contact Electrodes with Poly(3-octylthiophene) and Poly(aniline) as Ion-to-Electron Transducers Buffered with Electron-Ion-Exchanging Resin , 2006 .

[32]  Eric Bakker,et al.  Solid contact potentiometric sensors for trace level measurements. , 2006, Analytical chemistry.

[33]  J. Bobacka Conducting Polymer‐Based Solid‐State Ion‐Selective Electrodes , 2006 .

[34]  Ernö Pretsch,et al.  Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range , 2004 .

[35]  A. Michalska,et al.  Conducting polymer membranes for low activity potentiometric ion sensing. , 2004, Talanta.

[36]  A. Michalska,et al.  PEDOT films: multifunctional membranes for electrochemical ion sensing , 2004 .

[37]  A. Ivaska,et al.  All-Solid-State Chloride Sensors with Poly(3-Octylthiopene) Matrix and Trihexadecylmethylammonium Chlorides as an Ion Exchanger Salt , 2004 .

[38]  Johan Bobacka,et al.  Solution-cast films of poly(3,4-ethylenedioxythiophene) as ion-to-electron transducers in all-solid-state ion-selective electrodes , 2004 .

[39]  G. Cha,et al.  Molecular recognition of anions through hydrogen bonding stabilization of anion-ionophore adducts: a novel trifluoroacetophenone-based binding motif. , 2003, Organic letters.

[40]  Y. Vlasov,et al.  Carbonate Sensors Based on 4-Hexyltrifluoroacetophenone Modified by Acceptor Substituents in Phenyl Ring , 2003 .

[41]  N. F. Rooij,et al.  Optimization of the Composition of Interfaces in Miniature Planar Chloride Electrodes , 2003 .

[42]  A. Michalska,et al.  Lowering the Detection Limit of Ion-Selective Plastic Membrane Electrodes with Conducting Polymer Solid Contact and Conducting Polymer Potentiometric Sensors , 2003 .

[43]  M. Meyerhoff,et al.  Zirconium(IV)-porphyrins as novel ionophores for fluoride-selective polymeric membrane electrodes , 2002 .

[44]  Hakhyun Nam,et al.  All-solid-state carbonate-selective electrode based on a molecular tweezer-type neutral carrier with solvent-soluble conducting polymer solid contact. , 2002, Talanta.

[45]  A. Michalska,et al.  All-solid-state planar miniature ion-selective chloride electrode , 2002 .

[46]  Artur Dybko,et al.  Durable phosphate-selective electrodes based on uranyl salophenes , 2001 .

[47]  Yoon,et al.  Potentiometric evaluation of solvent polymeric carbonate-selective membranes based on molecular tweezer-type neutral carriers , 2000, Analytical chemistry.

[48]  Johan Bobacka,et al.  All‐Solid‐State Chloride‐Selective Electrode Based on Poly(3‐octylthiophene) and Tridodecylmethylammonium Chloride , 1999 .

[49]  A. Ivaska,et al.  Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycin , 1999 .

[50]  A. Ivaska,et al.  Characterization of a single-piece all-solid-state lithium-selective electrode based on soluble conducting polyaniline , 1999 .

[51]  A. Ivaska,et al.  Study on soluble polypyrrole as a component in all-solid-state ion-sensors , 1998 .

[52]  E. Bakker Determination of Unbiased Selectivity Coefficients of Neutral Carrier-Based Cation-Selective Electrodes , 1997 .

[53]  Johan Bobacka,et al.  Single-piece all-solid-state ion-selective electrode , 1995 .

[54]  A. Ivaska,et al.  Potentiometric response of poly(3-octylthiophene), poly(3-methylthiophene) and polythiophene in aqueous solutions. , 1993, Talanta.

[55]  Dermot Diamond,et al.  All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contact , 1992 .

[56]  H. J. James,et al.  Coated wire ion-selective electrodes. , 1971, Analytical chemistry.