Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve

Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 frame were performed and then followed by fluid-solid interaction analysis to simulate valve leaflet dynamics throughout the entire cardiac cycle. Modeling revealed that the S3 stent frame expanded well on BAV anatomy with an elliptical shape at the aortic annulus. Comparison of predicted S3 deformity as assessed by eccentricity and expansion indices demonstrated a good agreement with the measurement obtained from CT imaging. Blood particle flow analysis demonstrated a backward blood jet during diastole, whereas the predicted PVL flows corresponded well with those determined by transesophageal echocardiography. This study represents a further step towards the use of personalized simulations to virtually plan TAVI, aiming at improving not only the efficacy of the implantation but also the exploration of “off-label” applications as the TAVI in the setting of BAV patients. Graphical abstract Computational frameworks of TAVI in patients with stenotic bicuspid aortic valve

[1]  S. Pasta,et al.  Role of Computational Modeling in Thoracic Aortic Pathology: A Review , 2014, Journal of cardiac surgery.

[2]  Komarakshi R Balakrishnan,et al.  Dynamic analysis of the aortic valve using a finite element model. , 2002, The Annals of thoracic surgery.

[3]  Claudio Chiastra,et al.  Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery. , 2011, Journal of biomechanical engineering.

[4]  H. Jilaihawi,et al.  Transcatheter aortic valve implantation in bicuspid anatomy , 2015, Nature Reviews Cardiology.

[5]  H. Sievers,et al.  A classification system for the bicuspid aortic valve from 304 surgical specimens. , 2007, The Journal of thoracic and cardiovascular surgery.

[6]  Wei Sun,et al.  Modeling Left Ventricular Blood Flow Using Smoothed Particle Hydrodynamics , 2017, Cardiovascular engineering and technology.

[7]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[8]  Wei Sun,et al.  Fluid–Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics , 2016, Cardiovascular engineering and technology.

[9]  Giovanni Gentile,et al.  Three‐dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions , 2017, Artificial organs.

[10]  F. Migliavacca,et al.  On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid–Structure Interaction Approach , 2019, Cardiovascular Engineering and Technology.

[11]  W. Roberts,et al.  Frequency of congenitally bicuspid aortic valves in patients ≥80 years of age undergoing aortic valve replacement for aortic stenosis (with or without aortic regurgitation) and implications for transcatheter aortic valve implantation. , 2012, The American journal of cardiology.

[12]  Jan A S van der Heyden,et al.  Insight on patient specific computer modeling of transcatheter aortic valve implantation in patients with bicuspid aortic valve disease , 2019, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[13]  S. Achenbach,et al.  CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: an analysis of 105 patients , 2013, The International Journal of Cardiovascular Imaging.

[14]  J. Monaghan Smoothed Particle Hydrodynamics and Its Diverse Applications , 2012 .

[15]  F Auricchio,et al.  Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach , 2014, Computer methods in biomechanics and biomedical engineering.

[16]  S. Pasta,et al.  Predicting Outcome of Aortic Dissection with Patent False Lumen by Computational Flow Analysis , 2014 .

[17]  D. Berman,et al.  Computed tomography characteristics of the aortic valve and the geometry of SAPIEN 3 transcatheter heart valve in patients with bicuspid aortic valve disease , 2018, European heart journal cardiovascular Imaging.

[18]  M. Morice,et al.  Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis , 2013, Circulation. Cardiovascular interventions.

[19]  Ram P. Ghosh,et al.  Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage , 2018, Biomechanics and Modeling in Mechanobiology.

[20]  Alberto Redaelli,et al.  Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study , 2016, Journal of biomechanics.

[21]  M. Mack,et al.  Comparison of Efficacy and Safety of Transcatheter Aortic Valve Implantation in Patients With Bicuspid Versus Tricuspid Aortic Valves. , 2017, The American journal of cardiology.

[22]  W. Mao,et al.  Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model , 2017, PloS one.

[23]  Erich Wintermantel,et al.  Finite Element Investigation of Stentless Pericardial Aortic Valves: Relevance of Leaflet Geometry , 2010, Annals of Biomedical Engineering.

[24]  P. Wenaweser,et al.  Transcatheter aortic valve replacement in bicuspid aortic valve disease. , 2014, Journal of the American College of Cardiology.

[25]  Jeroen J. Bax,et al.  Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation. , 2011, The American journal of cardiology.

[26]  C. Kleinstreuera,et al.  Computational mechanics of Nitinol stent grafts , 2008 .

[27]  Jeroen J. Bax,et al.  Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis. , 2017, Journal of the American College of Cardiology.

[28]  E. Tay,et al.  Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis. , 2010, JACC. Cardiovascular interventions.

[29]  F Auricchio,et al.  Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: two clinical cases. , 2014, Journal of biomechanics.

[30]  Salvatore Pasta,et al.  Constitutive modeling of ascending thoracic aortic aneurysms using microstructural parameters. , 2016, Medical engineering & physics.

[31]  Ferdinando Auricchio,et al.  Finite element analysis of TAVI: Impact of native aortic root computational modeling strategies on simulation outcomes. , 2017, Medical engineering & physics.

[32]  Danny Bluestein,et al.  Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage , 2019, Medical & Biological Engineering & Computing.

[33]  Q. Wang,et al.  Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root. , 2018, Journal of biomechanical engineering.

[34]  J. Leipsic,et al.  Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve. , 2013, JACC. Cardiovascular interventions.

[35]  T. Dewey,et al.  Transcatheter Aortic Valve Implantation , 2009, Innovations.

[36]  S. Pasta,et al.  Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis. , 2013, Interactive cardiovascular and thoracic surgery.

[37]  Pascal Vranckx,et al.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. , 2012, Journal of the American College of Cardiology.

[38]  J. Leipsic,et al.  Bicuspid Aortic Valve Stenosis: Favorable Early Outcomes With a Next-Generation Transcatheter Heart Valve in a Multicenter Study. , 2016, JACC. Cardiovascular interventions.

[39]  Jeroen J. Bax,et al.  Prognostic Implications of Raphe in Bicuspid Aortic Valve Anatomy , 2017, JAMA cardiology.

[40]  N. Bressloff,et al.  Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root , 2016, Computer methods in biomechanics and biomedical engineering.

[41]  M. Mack,et al.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. , 2012, The Journal of thoracic and cardiovascular surgery.

[42]  S. Verma,et al.  Clinical and Pathophysiological Implications of a Bicuspid Aortic Valve , 2002, Circulation.

[43]  M. Morice,et al.  The feasibility of transcatheter aortic valve implantation using the Edwards SAPIEN 3 for patients with severe bicuspid aortic stenosis. , 2017, Journal of cardiology.

[44]  Armand Eker,et al.  Aortic annulus rupture during transcatheter aortic valve implantation: safe aortic root replacement. , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[45]  F Auricchio,et al.  Prediction of patient-specific post-operative outcomes of TAVI procedure: The impact of the positioning strategy on valve performance. , 2016, Journal of biomechanics.

[46]  R. Liotta,et al.  Acute Obstructive Thrombosis of Sapien 3 Valve After Valve-in-Valve Transcatheter Aortic Valve Replacement for Degenerated Mosaic 21 Valve. , 2018, JACC. Cardiovascular interventions.

[47]  C. Ward Clinical significance of the bicuspid aortic valve , 2000, Heart.