Automated flow pH-method for the determination of total free fatty acids content in edible oils.

An automated flow pH-method for the determination of titratable acidity (TA) in edible oil without titration is proposed, based on pH measurements on an oil sample emulsion in a suitable reagent. The developed flow pH system involves two constant rate flows: the flow of oils samples and the flow of reagent: triethanolamine+KNO3+H2O+i-PrOH, in which oils is insoluble. The flows are mixed in the mixer forming the emulsion in which the free fatty acids (FFA) extraction is started. Then, the emulsion is passed to the coil for completion of FFA extraction and thermostation and then forwarded to pH-cell for pH measurement. Using pH values and linear dependence of pH vs. log (TA) allows the TA determination. The optimum parameters for the automated flow pH-system have been found, i.e., volumes of the mixer and the coils, the rate of sample and reagent, pH and TA ranges. The results of the TA determination in the edible oils were statistically compared with the standard titration method.

[1]  W. Frenzel Enhanced performance of ion-selective electrodes in flow injection analysis: non-nernstian response, indirect determination, differential detection and modified reverse flow injection analysis , 1988 .

[2]  F. Kusu,et al.  Determination of acidity of coffee by flow injection analysis with electrochemical detection , 1997 .

[3]  M. Mascini,et al.  Determination of extra virgin olive oil acidity by FIA-titration , 2001 .

[4]  Miguel Valcárcel,et al.  An automated flow-reversal injection/liquid—liquid extraction approach to the direct determination of total free fatty acids in olive oils , 1996 .

[5]  Miguel Valcárcel,et al.  Direct automatic determination of free acidity in oils by flow-injection analysis , 1989 .

[6]  B. Lendl,et al.  Determination of Free Fatty Acids in Edible Oils by Continuous-Flow Analysis with FT-IR Spectroscopic Detection , 2001 .

[7]  E. G. Perkins,et al.  Deep frying: chemistry, nutrition, and practical applications. , 1996 .

[8]  B. P. Lim,et al.  Determination of free fatty acids in palm oil samples using non-aqueous flow injection titrimetric method , 2007 .

[9]  Moschos G. Polissiou,et al.  Automated flow injection spectrophotometric non-aqueous titrimetric determination of the free fatty acid content of olive oil , 1997 .

[10]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[11]  Ahmed Al-Alawi,et al.  Automated FTIR Analysis of Free Fatty Acids or Moisture in Edible Oils , 2006 .

[12]  A. Shenhar,et al.  pH-metric determination of acid values in vegetable oils without titration , 1996 .

[13]  M. D. Luque de Castro,et al.  A fully robotic method for the determination of acid values in olive oil without titration , 1998 .

[14]  Ahmed Al-Alawi,et al.  New FTIR method for the determination of FFA in oils , 2004 .