Specification of rotor side voltage source inverter of a doubly-fed induction generator for achieving ride-through capability

The ride-through capability of a doubly-fed induction generator under three-phase balanced voltage sags is examined, under the condition that the machine should have the capability of real and reactive power control during the external fault. Mathematical formulae for the peak rotor fault current and the required rotor voltage output under vector control are derived. Moreover, the DC link dynamics are incorporated into the analysis and it is shown that they can have a decisive impact on fault behaviour of the machine during voltage sags. Combined, a design methodology for the rotor side voltage source inverter aiming to achieve a ride-through capability at the lowest cost is described. Simulation results in PSCAD/EMTDC show very good agreement with the theoretical analysis.

[1]  Hadi Saadat,et al.  Power System Analysis , 1998 .

[2]  T. Thiringer,et al.  Modeling and experimental verification of grid interaction of a DFIG wind turbine , 2005, IEEE Transactions on Energy Conversion.

[3]  P. Kundur,et al.  Power system stability and control , 1994 .

[4]  Janaka Ekanayake,et al.  Dynamic modeling of doubly fed induction generator wind turbines , 2003 .

[5]  Nicholas Jenkins,et al.  Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm , 2004 .

[6]  Jan T. Bialasiewicz,et al.  Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey , 2006, IEEE Transactions on Industrial Electronics.

[7]  Nicholas Jenkins,et al.  Control of DFIG wind turbines , 2003 .

[8]  David J. Atkinson,et al.  Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder , 2000 .

[9]  M. B. Brennen,et al.  Vector analysis and control of advanced static VAr compensators , 1991 .

[10]  A. Petersson Analysis, Modeling and Control of Doubly-Fed Induction Generators for Wind Turbines , 2005 .

[11]  O. Anaya-Lara,et al.  Performance of Doubly Fed Induction Generator (DFIG) during Network Faults , 2005 .

[12]  Edward Wilson Kimbark,et al.  Power System Stability , 1948 .

[13]  Vladislav Akhmatov Variable-Speed Wind Turbines with Doubly-Fed Induction Generators Part IV: Uninterrupted Operation Features at Grid Faults with Converter Control Coordination , 2003 .

[14]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[15]  Vladislav Akhmatov Variable-speed Wind Turbines with Doubly-fed Induction Generators Part II: Power System Stability , 2002 .

[16]  Frede Blaabjerg,et al.  Control of Variable Speed Wind Turbines with Doubly-Fed Induction Generators , 2004 .

[17]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[18]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .

[19]  M.V.A. Nunes,et al.  Influence of the variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids , 2004 .