A Real-Time Programmable Pulsatile Flow Pump for In Vitro Cardiovascular Experimentation.

Benchtop in vitro experiments are valuable tools for investigating the cardiovascular system and testing medical devices. Accurate reproduction of the physiologic flow waveforms at various anatomic locations is an important component of these experimental methods. This study discusses the design, construction, and testing of a low-cost and fully programmable pulsatile flow pump capable of continuously producing unlimited cycles of physiologic waveforms. It consists of a gear pump actuated by an AC servomotor and a feedback algorithm to achieve highly accurate reproduction of flow waveforms for flow rates up to 300 ml/s across a range of loading conditions. The iterative feedback algorithm uses the flow error values in one iteration to modify the motor control waveform for the next iteration to better match the desired flow. Within four to seven iterations of feedback, the pump replicated desired physiologic flow waveforms to within 2% normalized RMS error (for flow rates above 20 mL/s) under varying downstream impedances. This pump device is significantly more affordable (∼10% of the cost) than current commercial options. More importantly, the pump can be controlled via common scientific software and thus easily implemented into large automation frameworks.

[1]  Niema M Pahlevan,et al.  In-vitro investigation of a potential wave pumping effect in human aorta. , 2013, Journal of biomechanics.

[2]  Giancarlo Pennati,et al.  A simulation protocol for exercise physiology in Fontan patients using a closed loop lumped-parameter model. , 2014, Journal of biomechanical engineering.

[3]  Charles A. Taylor,et al.  Development of a Physical Windkessel Module to Re-Create In Vivo Vascular Flow Impedance for In Vitro Experiments , 2011, Cardiovascular engineering and technology.

[4]  A. Fenster,et al.  Computer‐controlled flow simulator for MR flow studies , 1992, Journal of magnetic resonance imaging : JMRI.

[5]  Mark D. Huffman,et al.  AHA Statistical Update Heart Disease and Stroke Statistics — 2012 Update A Report From the American Heart Association WRITING GROUP MEMBERS , 2010 .

[6]  Kjell Lindström,et al.  A computer-controlled arbitrary flow wave form generator for physiological studies , 2000 .

[7]  P R Hoskins,et al.  A computer controlled flow phantom for generation of physiological Doppler waveforms , 1989, Physics in medicine and biology.

[8]  Arash Kheradvar,et al.  The Effects of Positioning of Transcatheter Aortic Valves on Fluid Dynamics of the Aortic Root , 2014, ASAIO journal.

[9]  D. Ku,et al.  Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries. , 1988, Archives of pathology & laboratory medicine.

[10]  William Tsai,et al.  Flow pumping system for physiological waveforms , 2010, Medical & Biological Engineering & Computing.

[11]  3-D flow characterization and shear stress in a stenosed carotid artery bifurcation model using stereoscopic PIV technique , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[12]  Charles A. Taylor,et al.  In vitro validation of finite-element model of AAA hemodynamics incorporating realistic outlet boundary conditions. , 2011, Journal of biomechanical engineering.