A New Plate for Planar Electrochromatography

A new bonded RP-18 sintered silica gel plate for use in reversed-phase planar electrochromatography has been prepared in our laboratory by fusing a mixture of silica gel and glass powder then reaction with octadecyltrichlorosilane. The plates have good chromatographic characteristics and other useful properties, for example mechanical stability, and can be regenerated by soaking the chro-matogram in acetone. Use of the new plate in a development chamber designed for planar electrochromatography, with a 2-kV intermittent voltage supply and a mobile phase prepared from aqueous acetonitrile containing 25 mM sodium acetate buffer, pH 5.0, resulted in good separation of five dyes.

[1]  J. Dorsey,et al.  Linear voltage profiles and flow homogeneity in pressurized planar electrochromatography. , 2006, Journal of chromatography. A.

[2]  J. Dorsey,et al.  Characterization of flow and voltage profiles in planar electrochromatography. , 2005, Journal of chromatography. A.

[3]  Jing Wang,et al.  Research on a Semi-Automatic Sample Applicator , 2005, JPC – Journal of Planar Chromatography – Modern TLC.

[4]  T. Dzido,et al.  Adaptation of a Horizontal DS Chamber to Planar Electrochromatography in a Closed System , 2004, JPC – Journal of Planar Chromatography – Modern TLC.

[5]  D. Nurok,et al.  Apparatus and initial results for pressurized planar electrochromatography. , 2004, Analytical chemistry.

[6]  C. Poole Thin-layer chromatography: challenges and opportunities. , 2003, Journal of chromatography. A.

[7]  D. Nurok,et al.  Role of buffer concentration and applied voltage in obtaining a good separation in planar electrochromatography. , 2003, Journal of chromatography. A.

[8]  I. Malinowska,et al.  The Effect of Electric Fields on Solute Migration and Mixture Separation in TLC , 2002, JPC – Journal of Planar Chromatography – Modern TLC.

[9]  T. Dzido,et al.  The Performance of Planar Electrochromatography in a Horizontal Chamber , 2002, JPC – Journal of Planar Chromatography – Modern TLC.

[10]  G. Mihǎilescu,et al.  Planar Dielectrochromatography on Non-Wetted Thin Layers , 2001, JPC – Journal of Planar Chromatography – Modern TLC.

[11]  M. Frost,et al.  Separation using planar chromatography with electroosmotic flow. , 2000, Journal of chromatography. A.

[12]  D. Nurok Peer Reviewed: Forced-Flow Techniques in Planar Chromatography , 2000 .

[13]  I. Wilson,et al.  Electroosmotically driven thin-layer electrochromatography on silica media , 1999 .

[14]  I. Wilson,et al.  Evaporation-induced solvent migration in electrically-driven thin layer chromatography , 1999 .

[15]  R. Kaiser,et al.  Planar electrochromatography Part 1. Planar electrochromatography on non-wetted thin-layers , 1994 .

[16]  D. Leyden,et al.  Ammonia-catalyzed silylation reactions of Cab-O-Sil with methoxymethylsilanes , 1987 .

[17]  T. Okumura [Sintered thin-layer chromatography. XIV. Thermal stability of organic adsorbents used for sintered thin-layer chromatography (author's transl)]. , 1976, Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan.

[18]  T. Okumura [Sintered thin-layer chromatography. XII. Thin-layer chromatography on porous metal oxides sintered plates (author's transl)]. , 1975, Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan.

[19]  R. Majors,et al.  Studies of Siloxane Phases Bonded to Silica Gel for Use in High Performance Liquid Chromatography , 1974 .

[20]  V. Pretorius,et al.  Electro-osmosis: A new concept for high-speed liquid chromatography , 1974 .

[21]  T. Okumura,et al.  Thin-layer chromatography on alumina-sintered glass plates , 1973 .

[22]  M. F. Burke,et al.  Role of tri- and dimethylsilanes in tailoring chromatographic adsorbents , 1973 .

[23]  T. Okumura,et al.  Thin-layer chromatography on silica gel and alumina sintered sticks , 1973 .

[24]  T. Okumura,et al.  Thin-layer chromatography on fluorescent sintered plates:Thin-layer chromatography on precoated adsorbent fixed with fused glass. IX , 1973 .

[25]  T. Okumura,et al.  Thin-layer chromatography on silica gel-sintered plates. , 1972, Journal of chromatography.

[26]  T. Okumura,et al.  [Thin-layer chromatography on precoated adsorbents fixed with fused glass. IV. A consideration on the welding mechanism of alumina sintered plate for thin-layer chromatography by means of scanning electron microscopic method]. , 1972, Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan.

[27]  T. Okumura,et al.  [Thin-layer chromatography on precoated adsorbents fixed with fused glass. II. Thin-layer chromatography on alumina sintered plate]. , 1972, Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan.

[28]  T. Okumura,et al.  A consideration on the welding mechanism of Kieselguhr sintered plate for thin-layer chromatography by means of scanning electron microscopic method , 1972 .

[29]  T. Okumura,et al.  Thin-layer chromatography on silica gel sintered plate , 1972 .