Development of a neurotechnological system for relieving phantom limb pain using transverse intrafascicular electrodes (TIME)

Abstract Phantom limb pain (PLP) is a chronic condition that develops in the majority of amputees. The underlying mechanisms are not completely understood, and thus, no treatment is fully effective. Based on recent studies, we hypothesize that electrical stimulation of afferent nerves might alleviate PLP by giving sensory input to the patient if nerve fibers can be activated selectively. The critical component in this scheme is the implantable electrode structure. We present a review of a novel electrode concept to distribute highly selective electrode contacts over the complete cross section of a peripheral nerve to create a distributed activation of small nerve fiber ensembles at the fascicular level, the transverse intrafascicular multichannel nerve electrode (TIME). The acute and chronic implantations in a small animal model exhibited a good surface and structural biocompatibility as well as excellent selectivity. Implantation studies on large animal models that are closer to human nerve size and anatomical complexity have also been conducted. They proved implant stability and the ability to selectively activate nerve fascicles in a limited proximity to the implant. These encouraging results have opened the way forward for human clinical trials in amputees to investigate the effect of selective electrical stimulation on PLP.

[1]  David Guiraud,et al.  Interfacing the neural system to restore deficient functions: from theoretical studies to neuroprothesis design. , 2012, Comptes rendus. Biologies.

[2]  W. Jensen,et al.  A transverse intrafascicular multichannel electrode (TIME) to treat phantom limb pain — Towards human clinical trials , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[3]  Silvestro Micera,et al.  Preliminary results on the design of a tool for inserting of transverse intrafascicular multichannel electrodes (TIME) into the peripheral nervous system , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  K. Horch,et al.  Object Discrimination With an Artificial Hand Using Electrical Stimulation of Peripheral Tactile and Proprioceptive Pathways With Intrafascicular Electrodes , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  X. Navarro,et al.  Evaluation of polyimide as substrate material for electrodes to interface the peripheral nervous system , 2011, 2011 5th International IEEE/EMBS Conference on Neural Engineering.

[6]  Silvestro Micera,et al.  A Computational Model for the Stimulation of Rat Sciatic Nerve Using a Transverse Intrafascicular Multichannel Electrode , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[7]  Thomas Stieglitz,et al.  Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichannel Electrode (TIME) in the Rat Sciatic Nerve , 2011, IEEE Transactions on Biomedical Engineering.

[8]  C. Azevedo-Coste,et al.  Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles , 2011, Journal of neural engineering.

[9]  W. Jensen,et al.  Evaluation of the stimulation selectivity of transverse intrafascicular multichannel electrodes in the chronic Göttingen mini-pig: preliminary results , 2011 .

[10]  W. Jensen,et al.  Comparison of acute stimulation selectivity of transverse and longitudinal intrafascicular electrodes in pigs , 2011 .

[11]  T. Stieglitz,et al.  Polymers for neural implants , 2011 .

[12]  T. Stieglitz,et al.  A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. , 2010, Biosensors & bioelectronics.

[13]  Xavier Navarro,et al.  Topographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat , 2010, Muscle & nerve.

[14]  W. Jensen,et al.  Dependence of implantation angle of the transverse, intrafascicular electrode (TIME) on selective activation of pig forelimb muscles , 2010 .

[15]  David Guiraud,et al.  A distributed architecture for activating the peripheral nervous system , 2009, Journal of neural engineering.

[16]  S. Micera,et al.  On the Use of Longitudinal Intrafascicular Peripheral Interfaces for the Control of Cybernetic Hand Prostheses in Amputees , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  X. Navarro,et al.  Neural plasticity after peripheral nerve injury and regeneration , 2007, Progress in Neurobiology.

[18]  H. Flor,et al.  Phantom limb pain: a case of maladaptive CNS plasticity? , 2006, Nature Reviews Neuroscience.

[19]  Stephen T Wegener,et al.  Phantom pain, residual limb pain, and back pain in amputees: results of a national survey. , 2005, Archives of physical medicine and rehabilitation.

[20]  K.P. Koch,et al.  Implantable biomedical microsystems for neural prostheses , 2005, IEEE Engineering in Medicine and Biology Magazine.

[21]  Silvestro Micera,et al.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.

[22]  Herta Flor,et al.  Neuroelectric source imaging of steady-state movement-related cortical potentials in human upper extremity amputees with and without phantom limb pain , 2004, Pain.

[23]  Udo Kischka,et al.  A neural network model of phantom limbs , 1995, Biological Cybernetics.

[24]  Karen D Davis,et al.  The effect of tactile and visual sensory inputs on phantom limb awareness. , 2003, Brain : a journal of neurology.

[25]  P. Rossini,et al.  Carpal tunnel syndrome modifies sensory hand cortical somatotopy: A MEG study , 2002, Human brain mapping.

[26]  H. Flor,et al.  Phantom movements and pain. An fMRI study in upper limb amputees. , 2001, Brain : a journal of neurology.

[27]  H. Flor,et al.  Effect of sensory discrimination training on cortical reorganisation and phantom limb pain , 2001, The Lancet.

[28]  N Birbaumer,et al.  Reorganization of Motor and Somatosensory Cortex in Upper Extremity Amputees with Phantom Limb Pain , 2001, The Journal of Neuroscience.

[29]  H. Flor,et al.  The relationship of perceptual phenomena and cortical reorganization in upper extremity amputees , 2001, Neuroscience.

[30]  N. Birbaumer,et al.  Does use of a myoelectric prosthesis prevent cortical reorganization and phantom limb pain? , 1999, Nature Neuroscience.

[31]  T. Elbert,et al.  Cortical reorganization and phantom phenomena in congenital and traumatic upper-extremity amputees , 1998, Experimental Brain Research.

[32]  T. Elbert,et al.  Phantom-limb pain as a perceptual correlate of cortical reorganization following arm amputation , 1995, Nature.

[33]  M. Calford,et al.  C-fibres provide a source of masking inhibition to primary somatosensory cortex , 1991, Proceedings of the Royal Society of London. Series B: Biological Sciences.

[34]  M. Merzenich,et al.  Functional reorganization of primary somatosensory cortex in adult owl monkeys after behaviorally controlled tactile stimulation. , 1990, Journal of neurophysiology.