Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy

BackgroundThis paper reports the development of an in-vitro technique allowing quantification of relative (not absolute) deformations measured at the level of the cancellous bone of the tibial proximal epiphysis (CBTPE) during knee flexion-extension. This method has been developed to allow a future study of the effects of low femoral osteotomies consequence on the CBTPE.MethodsSix strain gages were encapsulated in an epoxy resin solution to form, after resin polymerisation, six measurement elements (ME). The latter were inserted into the CBTPE of six unembalmed specimens, just below the tibial plateau. Knee motion data were collected by three-dimensional (3D) electrogoniometry during several cycles of knee flexion-extension. Intra- and inter-observer reproducibility was estimated on one specimen for all MEs. Intra-specimen repeatability was calculated to determine specimen's variability and the error of measurement. A varum and valgum chirurgical procedure was realised on another specimen to observed CBTPE deformation after these kind of procedure.ResultsAverage intra-observer variation of the deformation ranged from 8% to 9% (mean coefficient of variation, MCV) respectively for extension and flexion movement. The coefficient of multiple correlations (CMC) ranged from 0.93 to 0.96 for flexion and extension. No phase shift of maximum strain peaks was observed. Inter-observer MCV averaged 23% and 28% for flexion and extension. The CMC were 0.82 and 0.87 respectively for extension and flexion. For the intra-specimen repeatability, the average of mean RMS difference and the mean ICC were calculated only for flexion movement. The mean RMS variability ranged from 7 to 10% and the mean ICC was 0.98 (0.95 - 0.99). A Pearson's correlation coefficient was calculated showing that RMS was independent of signal intensity. For the chirurgical procedure, valgum and varum deviation seems be in agree with the frontal misalignment theory.ConclusionsResults show that the methodology is reproducible within a range of 10%. This method has been developed to allow analysis the indirect reflect of deformation variations in CBTPE before and after distal femoral osteotomies. The first results of the valgum and varum deformation show that our methodology allows this kind of measurement and are encourageant for latter studies. It will therefore allow quantification and enhance the understanding of the effects of this kind of surgery on the CBTPE loading.

[1]  S. Herring,et al.  Bone surface strains and internal bony pressures at the jaw joint of the miniature pig during masticatory muscle contraction. , 2000, Archives of oral biology.

[2]  A A Amis,et al.  Accuracy of an electromagnetic measurement device and application to the measurement and description of knee joint motion , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  B. Beynnon,et al.  In vivo loads in the medial compartment of the rabbit knee. , 2005, Clinical biomechanics.

[4]  E. Little,et al.  An Experimental Technique for the Investigation of Three-Dimensional Stress in Bone Cement Underlying a Tibial Plateau , 1989, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  W. Taylor,et al.  Distribution of bone mineral density with age and gender in the proximal tibia. , 2004, Clinical biomechanics.

[6]  Victor Sholukha,et al.  Calibration and validation of 6 DOFs instrumented spatial linkage for biomechanical applications. A practical approach. , 2004, Medical engineering & physics.

[7]  H F J M Koopman,et al.  Morphological muscle and joint parameters for musculoskeletal modelling of the lower extremity. , 2005, Clinical biomechanics.

[8]  Eric Lespessailles,et al.  Evaluation of macrostructural bone biomechanics. , 2007, Joint, bone, spine : revue du rhumatisme.

[9]  C. Benhamou,et al.  Iconographies supplémentaires de l'article : Analyse des propriétés biomécaniques de l'os à l'échelle macroscopique , 2007 .

[10]  Marco Viceconti,et al.  Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy. , 2006, Journal of biomechanics.

[11]  A A Amis,et al.  The effect of trochleoplasty on patellar stability and kinematics: a biomechanical study in vitro. , 2008, The Journal of bone and joint surgery. British volume.

[12]  Marco Viceconti,et al.  Development and validation of a technique for strain measurement inside polymethyl methacrylate , 2000 .

[13]  William M. Murray,et al.  The Bonded Electrical Resistance Strain Gage: An Introduction , 1992 .

[14]  B. Morrey,et al.  Distal femoral varus osteotomy for painful genu valgum. A five-to-11-year follow-up study. , 1993, Clinical orthopaedics and related research.

[15]  P. Aglietti,et al.  Distal femoral varus osteotomy in the valgus osteoarthritic knee. , 2000, The American journal of knee surgery.

[16]  Gunnar Németh,et al.  Tibiofemoral contact points relative to flexion angle measured with MRI. , 2002, Clinical biomechanics.

[17]  Amy L Lerner,et al.  Predicting regional variations in trabecular bone mechanical properties within the human proximal tibia using MR imaging. , 2008, Bone.

[18]  Ming Ding,et al.  Age variations in the properties of human tibial trabecular bone. , 1997, The Journal of bone and joint surgery. British volume.

[19]  M. Dalstra,et al.  Age variations in the properties of human tibial trabecular bone and cartilage , 1997, Acta orthopaedica Scandinavica. Supplementum.

[20]  L. S. Matthews,et al.  The mechanical properties of human tibial trabecular bone as a function of metaphyseal location. , 1983, Journal of biomechanics.

[21]  T. Fukubayashi,et al.  The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints. , 1980, Acta orthopaedica Scandinavica.

[22]  S Van Sint Jan,et al.  Registration of 6-DOFs electrogoniometry and CT medical imaging for 3D joint modeling. , 2002, Journal of biomechanics.

[23]  P. Maquet The biomechanics of the knee and surgical possibilities of healing osteoarthritic knee joints. , 1980, Clinical orthopaedics and related research.

[24]  T. Johnson,et al.  Anterior tibial post impingement in a posterior stabilized total knee arthroplasty , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[25]  B. Baillon,et al.  Modifications de la cinématique du genou et des bras de levier du quadriceps et des ischio-jambiers après ostéotomie tibiale haute "curviplane" de valgisation ou de varisation: étude in vitro. , 2006 .