A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient‐specific aortic model

Left ventricular assist devices (LVADs) are mechanical supports used in case of heart failure. Little is known as the height of the anastomosis in aorta might influence the hemodynamic. The aim of the study was to evaluate the fluid dynamic behavior due to the outflow graft placement of a continuous flow LVAD in ascending aorta and to identify the insertion site with the best hemodynamic profile. Computational fluid dynamic studies were carried out to analyze 4 different anastomosis locations in a patient-specific aorta 3D model coupled with a lumped parameters model: 1 cm (case 1), 2 cm (case 2), 3 cm (case 3) and 4 cm (case 4) above the ST junction. In cases 1 and 2, epiaortic vessels presented a steady flow, while in cases 3 and 4 the flow was whirling. Moreover, maximum velocity occurred before: brachiocephalic trunk (case 1), brachiocephalic and left carotid arteries (case 2), left carotid and left subclavian artery (case 3) and left subclavian vessel and upper wall of aortic arch (case 4). Maximum time averaged wall shear stress (TAWSS) was located in: the ascending aorta (cases 1 and 2), the inferior curvature of the arch (case 3); at the origin of epiaortic vessels (case 4). Furthermore, a flow recirculation (cases 1 and 2), a blood stagnation and chaotic flow (cases 3 and 4) occurred above the aortic valve. The results suggested that the placement of the outflow graft at 2 cm above the ST junction gave the most favorable hemodynamic profile.

[1]  A. Renzulli,et al.  Late de novo aortic regurgitation with the Jarvik 2000 Flowmaker® left ventricular assist device. , 2012, The International journal of artificial organs.

[2]  M. Loebe,et al.  Influence of LVAD Cannula Outflow Tract Location on Hemodynamics in the Ascending Aorta: A Patient-Specific Computational Fluid Dynamics Approach , 2012, ASAIO journal.

[3]  W. Cohn,et al.  A less invasive approach to axial flow pump insertion. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  Claudio Chiastra,et al.  Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases. , 2013, Medical engineering & physics.

[5]  Karen May-Newman,et al.  Effect of Left Ventricular Assist Device Outflow Conduit Anastomosis Location on Flow Patterns in the Native Aorta , 2006, ASAIO journal.

[6]  A. Anyanwu Technique for less invasive implantation of Heartmate II left ventricular assist device without median sternotomy. , 2011, Seminars in thoracic and cardiovascular surgery.

[7]  Charles A. Taylor,et al.  Patient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries , 2010, Annals of Biomedical Engineering.

[8]  A. Quarteroni,et al.  On the coupling of 3D and 1D Navier-Stokes equations for flow problems in compliant vessels , 2001 .

[9]  W. Cohn,et al.  In vivo evaluation of the HeartWare centrifugal ventricular assist device. , 2007, Texas Heart Institute journal.

[10]  Francis D. Pagani,et al.  The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients , 2010, Circulation. Heart failure.

[11]  M. Caruso,et al.  A numerical analysis of the aortic blood flow pattern during pulsed cardiopulmonary bypass , 2015, Computer methods in biomechanics and biomedical engineering.

[12]  M C Oz,et al.  Implantable left ventricular assist devices. , 1998, The New England journal of medicine.

[13]  L. Wilson,et al.  Mitral Valve Repair at the Time of Continuous-Flow Left Ventricular Assist Device Implantation Confers Meaningful Decrement in Pulmonary Vascular Resistance , 2013, ASAIO journal.

[14]  M. Loebe,et al.  Comparison of hemodynamics in the ascending aorta between pulsatile and continuous flow left ventricular assist devices using computational fluid dynamics based on computed tomography images. , 2014, Artificial organs.

[15]  Charles A. Taylor,et al.  Outflow boundary conditions for three-dimensional finite element modeling of blood flow and pressure in arteries , 2006 .

[16]  A. Haverich,et al.  Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: upper hemisternotomy combined with anterolateral thoracotomy. , 2012, The Journal of thoracic and cardiovascular surgery.

[17]  Christof Karmonik,et al.  Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta. , 2014, The Journal of thoracic and cardiovascular surgery.

[18]  A. Quarteroni,et al.  Connecting Ventricular Assist Devices to the Aorta: a Numerical Model , 2012 .

[19]  Esra Sorgüven,et al.  Effect of LVAD Outlet Graft Anastomosis Angle on the Aortic Valve, Wall, and Flow , 2012, ASAIO journal.

[20]  Thomas J. R. Hughes,et al.  Patient-specific isogeometric fluid–structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device , 2009 .

[21]  J. Rogers,et al.  Surgical correction of aortic valve insufficiency after left ventricular assist device implantation. , 2013, The Journal of thoracic and cardiovascular surgery.

[22]  S. Deutsch,et al.  Comparative Study of Continuous and Pulsatile Left Ventricular Assist Devices on Hemodynamics of a Pediatric End-to-Side Anastomotic Graft , 2010, Cardiovascular engineering and technology.

[23]  P. Jansz,et al.  Results of the Registry To EValuate the HeartWare Left Ventricular Assist System (The REVOLVE Registry) , 2013 .

[24]  Thomas J. R. Hughes,et al.  Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis , 2004, Annals of Biomedical Engineering.

[25]  Charles A. Taylor,et al.  Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: scientific basis. , 2013, Journal of the American College of Cardiology.

[26]  Nir Uriel,et al.  Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[27]  M. Deng,et al.  Continuous flow blood pumps: the new gold standard for advanced heart failure? , 2013, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[28]  Charles A. Taylor,et al.  Augmented Lagrangian method for constraining the shape of velocity profiles at outlet boundaries for three-dimensional finite element simulations of blood flow , 2009 .

[29]  Charles A. Taylor,et al.  On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model , 2009, Annals of Biomedical Engineering.

[30]  L. Samuels,et al.  Left ventricular assist device implantation in high risk destination therapy patients: an alternative surgical approach , 2012, Journal of Cardiothoracic Surgery.

[31]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[32]  Christoph Benk,et al.  Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[33]  M. Laumen,et al.  The impact of aortic/subclavian outflow cannulation for cardiopulmonary bypass and cardiac support: a computational fluid dynamics study. , 2009, Artificial organs.

[34]  M. Olufsen,et al.  Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow Conditions , 2000, Annals of Biomedical Engineering.

[35]  Mehmet Yasar Gundogdu,et al.  A critical review on blood flow in large arteries; relevance to blood rheology, viscosity models, and physiologic conditions , 2008 .