Use of a Doppler guide wire for intravascular blood flow measurements: a validation study for potential neurologic endovascular applications.

PURPOSE To conduct a validation study of a Doppler guide wire for potential neuroendovascular applications. METHODS A 12-MHz, 0.018-inch Doppler guide wire was evaluated in eight swine under various blood flow conditions using two types of in vivo cerebrovascular models (physiologic and arteriovenous shunting). Flow conditions were mechanically and pharmacologically altered. Doppler average peak velocity was compared with volumetric blood flow, and flow profile corrections were calculated and analyzed. Qualitative aspects of the Doppler guide wire spectra were also assessed. RESULTS Plots of average peak velocity versus volumetric blood flow showed excellent linear relationships (r2 > 0.94), which were maintained at high flow conditions (average peak velocity, 99 to 236 cm/sec; volumetric blood flow, 392 to 889 mL/min). Values of flow profile correction varied from 0.43 to 0.94 and showed no consistent relationship to changes in volumetric blood flow. CONCLUSIONS The excellent correlation between average peak velocity and volumetric blood flow over a wide range of blood flow conditions and the additional qualitative information of the Doppler guide wire spectra establish a foundation for clinical implementation. The unpredictable variations of flow profile corrections remain obstacles for calculating volumetric blood flow based on Doppler guide wire average peak velocity.

[1]  H. Nornes,et al.  Intraoperative evaluation of cerebral hemodynamics using directional Doppler technique. Part 2: Saccular aneurysms. , 1979, Journal of neurosurgery.

[2]  C. Jungreis,et al.  Blood pressure changes in feeders to cerebral arteriovenous malformations during therapeutic embolization. , 1989, AJNR. American journal of neuroradiology.

[3]  H. M. Payne,et al.  Validation of A Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity , 1992, Circulation.

[4]  T. Karino,et al.  Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries. , 1990, Circulation research.

[5]  R. Aaslid,et al.  Evaluation of cerebral AVM's using transcranial Doppler ultrasound. , 1986, Journal of neurosurgery.

[6]  G. Duckwiler,et al.  Intravascular microcatheter pressure monitoring: experimental results and early clinical evaluation. , 1990, AJNR. American journal of neuroradiology.

[7]  G R Duckwiler,et al.  Fluid Equations Applied to Blood Flow Measurement Using Digital Videodensitometry , 1992, Investigative radiology.

[8]  J. P. Mickle,et al.  Venous pressure measurements in vein of Galen aneurysms. , 1989, AJNR. American journal of neuroradiology.

[9]  M. Kern,et al.  Detection of coronary collateral flow by a Doppler-tipped guide wire during coronary angioplasty. , 1991, American heart journal.

[10]  G. Duckwiler,et al.  Technical feasibility and performance studies of a Doppler guide wire for potential neuroendovascular applications. , 1994, AJNR. American journal of neuroradiology.

[11]  K Doi,et al.  Measurement of absolute flow rate in vessels using a stereoscopic DSA system. , 1989, Physics in medicine and biology.

[12]  M. Kern,et al.  Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty. , 1992, Journal of the American College of Cardiology.

[13]  H. Nornes,et al.  Hemodynamic aspects of cerebral arteriovenous malformations. , 1980, Journal of neurosurgery.