Effects of high frequency modeling & grounding system parameters on transient recovery voltage across vacuum circuit breakers for capacitor switching in wind power plants

Abstract This paper investigates the transient recovery voltages across vacuum circuit breakers used for the switching shunt capacitor bank in wind power plants, which are connected to the power system. Consideration has been given to high frequency models of all power system components, such as, the transformer, wind power plant generator, cable, surge arrester, vacuum circuit breaker and grounding system. The initial phase of study reproduced the results of previous work. In the second phase, the influence of different parameters, such as, the grounding system network, current injection point location to the grounding system, soil resistivity, grounding system length segment and soil ionization phenomena in the grounding system on transient recovery voltage, have been investigated via EMTP-RV. The results show that consideration of the high frequency behavior of the grounding system in wind power plants for prediction of transient recovery voltages is very important.

[1]  L. A. Snider,et al.  Overvoltages and reignition behavior of vacuum circuit breaker , 2003 .

[2]  Martin Hogdahl,et al.  Transients in Wind Power Plants—Part I: Modeling Methodology and Validation , 2012 .

[3]  Tao Zhang,et al.  Study on Switching Overvoltage in Off-Shore Wind Farms , 2014, IEEE Transactions on Applied Superconductivity.

[4]  Dragan Poljak,et al.  Transient analysis of grounding systems for wind turbines , 2012 .

[5]  Transient Recovery Voltage Investigation in the Application of 15 kV Circuit Breaker Failure , 2005 .

[6]  Babak Badrzadeh,et al.  Transient Recovery Voltages Caused by Capacitor Switching in Wind Power Plants , 2012, IEEE Transactions on Industry Applications.

[7]  A. Greenwood,et al.  Electrical transients in power systems , 1971 .

[8]  Mehdi Nafar,et al.  Comparison of IEEE and Pinceti Models of Surge Arresters , 2014 .

[9]  MEHDI NAFAR,et al.  A novel parameter estimation method for metal oxide surge arrester models , 2011 .

[10]  V. Terzija,et al.  General Analysis of Vacuum Circuit Breaker Switching Overvoltages in Offshore Wind Farms , 2016, IEEE Transactions on Power Delivery.

[11]  D. W. Durbak Surge arrester modeling , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[12]  C. Christopoulos,et al.  The Transmission Line Modeling Method to Represent the Soil Ionization Phenomenon in Grounding Systems , 2014, IEEE Transactions on Magnetics.

[13]  S. Dau,et al.  Modelling of metal oxide surge arresters as elements of overvoltage protection systems , 2012, 2012 International Conference on Lightning Protection (ICLP).

[14]  Ramasamy Natarajan Power System Capacitors , 2005 .

[15]  Mario Paolone,et al.  Transient Recovery Voltages in Vacuum Circuit Breakers Generated by the Interruption of Inrush Currents of Large Motors , 2011 .

[16]  J.A. Martinez,et al.  Parameter determination for modeling systems transients-Part V: Surge arresters , 2005, IEEE Transactions on Power Delivery.

[17]  C. Christopoulos,et al.  Effective length study of grounding electrod reached by lightning based on Transmission Line modelling Method , 2012, 2012 IEEE International Symposium on Electromagnetic Compatibility.

[18]  R.P.P. Smeets,et al.  Experimental and Theoretical Analysis of Vacuum Circuit Breaker Prestrike Effect on a Transformer , 2009, IEEE Transactions on Power Delivery.

[19]  Chih-Ju Chou,et al.  Study on Switching Overvoltage in Fuhai Offshore Wind Farm in Taiwan , 2015 .

[20]  E. H. Camm,et al.  Current-limiting inductors used in capacitor bank applications and their impact on fault current interruption , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[21]  Mohamed A. Izzularab,et al.  High-frequency modeling of Zafarana wind farm and reduction of backflow current-overvoltages , 2014 .

[22]  Bjorn Gustavsen,et al.  Investigation of the Overvoltage and Fast Transient Phenomena on Transformer Terminals by Taking Into Account the Grounding Effects , 2015, IEEE Transactions on Industry Applications.

[23]  B. Gustavsen,et al.  Parameter determination for modeling system transients-Part II: Insulated cables , 2005, IEEE Transactions on Power Delivery.

[24]  C.A. Christodoulou,et al.  Simulation of metal oxide surge arresters behavior , 2008, 2008 IEEE Power Electronics Specialists Conference.

[25]  Pramuk Unahalekhaka,et al.  Simplified Modeling of Metal Oxide Surge Arresters , 2014 .

[26]  G. C. Paap,et al.  Investigation of the circuit breaker reignition overvoltages caused by no‐load transformer switching surges , 2001 .

[27]  Lars Liljestrand,et al.  Vacuum circuit breaker and transformer interaction in a cable system , 2013 .