An Ex Vivo Platform to Simulate Cardiac Physiology: A New Dimension for Therapy Development and Assessment

Purpose Cardiac research and development of therapies and devices is being done with in silico models, using computer simulations, in vitro models, for example using pulse duplicators or in vivo models using animal models. These platforms, however, still show essential gaps in the study of comprehensive cardiac mechanics, hemodynamics, and device interaction. The PhysioHeart platform was developed to overcome these gaps by the ability to study cardiac hemodynamic functioning and device interaction ex vivo under in vivo conditions. Methods Slaughterhouse pig hearts (420 ± 30 g) were used for their morphological and physiological similarities to human hearts. Hearts were arrested, isolated and transported similar to transplantation protocols. After preparation, the hearts were connected to a special circulatory system that has been engineered using physical and medical principles. Through coronary reperfusion and controlled cardiac loading, physiological cardiac performance was achieved while hemodynamic parameters were continuously monitored. Results Normal cardiac hemodynamic performance was achieved both qualitatively, in terms of pulse waveforms, and quantitatively, in terms of average cardiac output (4 l/min) and pressures (110/75 mmHg). Cardiac performance was controlled and kept at normal levels for up to 4 hours, with only minor deterioration of hemodynamic performance. Conclusions With the PhysioHeart platform we were able to reproduce normal physiological cardiac conditions ex vivo. The platform enables us to study, under different but controlled physiological conditions, form, function, and device interaction through monitoring of performance parameters and intra-cardiac visualization. Although the platform has been used for pig hearts, application of the underlying physical and engineering principles to physiologically comparable hearts from different origin is rather straightforward.

[1]  Marco Stijnen,et al.  Images in cardiovascular medicine. Direct endoscopic visual assessment of a transcatheter aortic valve implantation and performance in the Physioheart, an isolated working heart platform. , 2010, Circulation.

[2]  D. Sigg,et al.  In vivo versus in vitro comparison of swine cardiac performance: induction of cardiodepression with halothane. , 2006, European journal of pharmacology.

[3]  P. Iaizzo,et al.  Isolated four-chamber working swine heart model. , 2000, The Annals of thoracic surgery.

[4]  Toshiaki Akita,et al.  Pressure-volume relationship in isolated working heart with crystalloid perfusate in swine and imaging the valve motion. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  O. Langendorff,et al.  Untersuchungen am überlebenden Säugethierherzen , 1895, Archiv für die gesamte Physiologie des Menschen und der Tiere.

[6]  H. Suga,et al.  End-diastolic and end-systolic ventricular volume clamper for isolated canine heart. , 1977, The American journal of physiology.

[7]  E. Verbeken,et al.  Left ventricular support by catheter-mounted axial flow pump reduces infarct size. , 2003, Journal of the American College of Cardiology.

[8]  Paul A Iaizzo,et al.  A novel ex vivo heart model for the assessment of cardiac pacing systems. , 2005, Journal of biomechanical engineering.

[9]  O. Langendorff,et al.  Untersuchungen am überlebenden Säugethierherzen , 2005, Archiv für die gesamte Physiologie des Menschen und der Tiere.

[10]  Marcel C M Rutten,et al.  A physiologically representative in vitro model of the coronary circulation. , 2004, Physiological measurement.

[11]  K Sagawa,et al.  Impedance loading servo pump system for excised canine ventricle. , 1982, The American journal of physiology.

[12]  F P T Baaijens,et al.  A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve. , 2003, Journal of biomechanics.

[13]  A. Bruschke,et al.  Influence of mitral valve prosthesis or rigid mitral ring on left ventricular pump function. A study on exposed and isolated blood-perfused porcine hearts. , 1989, Circulation.

[14]  A. Bruschke,et al.  Comparison of rigid and flexible rings for annuloplasty of the porcine mitral valve. , 1990, Circulation.

[15]  W. Konertz,et al.  Isolated hemoperfused heart model of slaughterhouse pigs , 2001, The International journal of artificial organs.

[16]  N. Stergiopulos,et al.  Total arterial inertance as the fourth element of the windkessel model. , 1999, American journal of physiology. Heart and circulatory physiology.

[17]  齋藤 俊英,et al.  Mitral valve motion assessed by high-speed video camera in isolated swine heart , 2007 .

[18]  Branislav Radovancevic,et al.  Ex vivo resuscitation of adult pig hearts. , 2003, Texas Heart Institute journal.

[19]  Berend E. Westerhof,et al.  The arterial Windkessel , 2009, Medical & Biological Engineering & Computing.

[20]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.