Kinematic and dynamic analysis of an anatomically based knee joint.

This paper presents a knee-joint model to provide a better understanding on the interaction between natural joints and artificial mechanisms for design and control of rehabilitation exoskeletons. The anatomically based knee model relaxes several commonly made assumptions that approximate a human knee as engineering pin-joint in exoskeleton design. Based on published MRI data, we formulate the kinematics of a knee-joint and compare three mathematical approximations; one model bases on two sequential circles rolling a flat plane; and the other two are mathematically differentiable ellipses-based models with and without sliding at the contact. The ellipses-based model taking sliding contact into accounts shows that the rolling-sliding ratio of a knee-joint is not a constant but has an average value consistent with published measurements. This knee-joint kinematics leads to a physically more accurate contact-point trajectory than methods based on multiple circles or lines, and provides a basis to derive a knee-joint kinetic model upon which the effects of a planar exoskeleton mechanism on the internal joint forces and torque during flexion can be numerically investigated. Two different knee-joint kinetic models (pin-joint approximation and anatomically based model) are compared against a condition with no exoskeleton. The leg and exoskeleton form a closed kinematic chain that has a significant effect on the joint forces in the knee. Human knee is more tolerant than pin-joint in negotiating around a singularity but its internal forces increase with the exoskeleton mass-to-length ratio. An oversimplifying pin-joint approximation cannot capture the finite change in the knee forces due to the singularity effect.

[1]  Toshio Fukuda,et al.  An exoskeletal robot for human shoulder joint motion assist , 2003 .

[2]  Tadasuke Katsuhara,et al.  Model Analysis of Lower Limb at Deep Knee Flexion , 2007 .

[3]  V. Dietz,et al.  Treadmill training of paraplegic patients using a robotic orthosis. , 2000, Journal of rehabilitation research and development.

[4]  P. Walker,et al.  A computer model with surface friction for the prediction of total knee kinematics. , 1997, Journal of biomechanics.

[5]  Guoan Li,et al.  Comments on "validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion". , 2008 .

[6]  Yoshiyuki Sankai,et al.  Power assist method based on Phase Sequence and muscle force condition for HAL , 2005, Adv. Robotics.

[7]  J. Lynch,et al.  Comparison of fixed-flexion positioning with fluoroscopic semi-flexed positioning for quantifying radiographic joint-space width in the knee: test-retest reproducibility , 2003, Skeletal Radiology.

[8]  H. Kazerooni,et al.  Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX) , 2006, IEEE/ASME Transactions on Mechatronics.

[9]  H. K. Low Initial experiments on a leg mechanism with a flexible geared joint and footpad , 2005, Adv. Robotics.

[10]  M G Pandy,et al.  Computer modeling and simulation of human movement. , 2001, Annual review of biomedical engineering.

[11]  Nikolaos G. Tsagarakis,et al.  Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training , 2003, Auton. Robots.

[12]  A A Amis,et al.  Knee joint motion: Description and measurement , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[13]  V. Pinskerova,et al.  Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee , 2000 .

[14]  Guoan Li,et al.  Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. , 2008, Journal of biomechanics.

[15]  M. A. Lafortune,et al.  Skin marker displacement at the knee joint , 1993 .

[16]  Peter C Liacouras,et al.  Computational modeling to predict mechanical function of joints: application to the lower leg with simulation of two cadaver studies. , 2007, Journal of biomechanical engineering.

[17]  J J O'Connor,et al.  Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. , 1999, Journal of biomechanics.

[18]  M. Hull,et al.  A finite element model of the human knee joint for the study of tibio-femoral contact. , 2002, Journal of biomechanical engineering.

[19]  Harry F. Davis,et al.  Introduction to vector analysis , 1961 .

[20]  Frans C. T. van der Helm,et al.  A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots , 2006, Int. J. Robotics Res..

[21]  Daniel P. Ferris,et al.  Learning to walk with a robotic ankle exoskeleton. , 2007, Journal of biomechanics.

[22]  Daniel P. Ferris,et al.  An ankle-foot orthosis powered by artificial pneumatic muscles. , 2005, Journal of applied biomechanics.