Impact of the Bird-Beak Configuration on Postoperative Outcome After Thoracic Endovascular Aortic Repair: A Meta-analysis

Purpose: To investigate the association between the bird-beak configuration (BBC), a wedge-shaped gap between the undersurface of a thoracic endograft and the lesser curvature of the arch after thoracic endovascular aortic repair (TEVAR), and postoperative outcome after TEVAR. Methods: The study was performed according to the PRISMA guidelines. The PubMed, EMBASE, and Cochrane databases were searched to identify all case series reporting BBC after TEVAR between 2006 and April 2018. Data analysis was performed considering the difference in the risk of complications for presence vs absence of BBC. After screening 1633 articles, 21 studies were identified that matched the selection criteria; 12 of these reported detailed information to investigate the postoperative outcome using proportion meta-analysis with a random effects model. The pooled risk difference is reported with the 95% confidence interval (CI). Heterogeneity of the included studies was assessed with the I2 statistic (low 25%, medium 50%, high 75%). Results: Complications occurred within a range of 0 to 72 months in 14.7% (95% CI 7.4% to 27.3%) of patients with BBC and in 6.3% (95% CI 2.5% to 15.4%) of patients without BBC. A cumulative incidence could not be assessed. The summary risk difference was 11.1% (95% CI −0.1% to 22.3%, p=0.052). There was significant heterogeneity (I2=85.6%). The Egger test did not show evidence of publication bias (p=0.975). When specifically considering type Ia endoleak and endograft migration, the risk difference between BBC and non-BBC patients was 8.2% (95% CI 0.3% to 16.1%, p=0.042; I2=69.0%). The specific risk difference for endograft collapse/infolding and thrombosis was 3.7% (95% CI −3.5% to 11.1%, p=0.308; I2=10.2%). Conclusion: At present the literature does not provide statistical evidence to establish an overall prognostic value of the BBC. Nevertheless, the BBC appears to be associated with a high risk of type Ia endoleak and endograft migration, which warrants specific and long-term surveillance. Clinically relevant values for BBC grading should be established to perhaps define indications for preemptive treatment based on the presence of BBC only.

[1]  Rodrigo M Romarowski,et al.  The Modified Arch Landing Areas Nomenclature identifies hostile zones for endograft deployment: a confirmatory biomechanical study in patients treated by thoracic endovascular aortic repair†. , 2018, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  Valdir Grassi,et al.  Computational simulation of TEVAR in the ascending aorta for optimal endograft selection: A patient-specific case study , 2018, Comput. Biol. Medicine.

[3]  S. Bellmunt Montoya,et al.  Long-Term Outcomes of Thoracic Endovascular Aortic Repair Focused on Bird Beak and Oversizing in Blunt Traumatic Thoracic Aortic Injury. , 2018, Annals of vascular surgery.

[4]  Rodrigo M Romarowski,et al.  The Modified Arch Landing Areas Nomenclature (MALAN) Improves Prediction of Stent Graft Displacement Forces: Proof of Concept by Computational Fluid Dynamics Modelling. , 2018, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[5]  G. Piffaretti,et al.  The Evaluation of Aortic Diameter Changes During Long-Term Follow-Up After Endovascular Treatment of Acute Blunt Traumatic Thoracic Aortic Injuries , 2018, Vascular and endovascular surgery.

[6]  W. Fu,et al.  Early outcomes of the conformable stent graft for acute complicated and uncomplicated type B aortic dissection , 2017, Journal of vascular surgery.

[7]  Yonggang Wang,et al.  Morphology and Outcomes of Total Endovascular Treatment of Type B Aortic Dissection with Aberrant Right Subclavian Artery. , 2017, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[8]  Y. Sawa,et al.  Type 1a endoleak following Zone 1 and Zone 2 thoracic endovascular aortic repair: effect of bird‐beak configuration† , 2017, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[9]  F. Moll,et al.  A geometric reappraisal of proximal landing zones for thoracic endovascular aortic repair according to aortic arch types , 2017, Journal of vascular surgery.

[10]  J. Appoo,et al.  Complications at the Proximal Landing Zone of Endovascular Stent Grafts Deployed in Surgically Replaced Ascending Aorta. , 2016, The Annals of thoracic surgery.

[11]  D. Böckler,et al.  Thoracic Endovascular Aortic Repair of Aortic Arch Pathologies with the Conformable Thoracic Aortic Graft: Early and 2 year Results from a European Multicentre Registry. , 2016, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[12]  D. Böckler,et al.  Device Conformability and Morphological Assessment After TEVAR for Aortic Type B Dissection: A Single-Centre Experience with a Conformable Thoracic Stent-Graft Design , 2015, Medical science monitor basic research.

[13]  Salvatore Pasta,et al.  Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair , 2015, Comput. Biol. Medicine.

[14]  T. Fukuda,et al.  Utility of Chimney Stentgraft Technique for Patients with Short Zone 1. , 2015, Annals of vascular diseases.

[15]  V. Deplano,et al.  Risk Factor Analysis of Bird Beak Occurrence after Thoracic Endovascular Aortic Repair. , 2015, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[16]  N. Merchant,et al.  Midterm results of endovascular stent grafts in the proximal aortic arch (zone 0): an imaging perspective. , 2015, The Canadian journal of cardiology.

[17]  O Kuss,et al.  Statistical methods for meta‐analyses including information from studies without any events—add nothing to nothing and succeed nevertheless , 2015, Statistics in medicine.

[18]  Karl Rohr,et al.  Aortic morphometry at endograft position as assessed by 3D image analysis affects risk of type I endoleak formation after TEVAR , 2015, Langenbeck's Archives of Surgery.

[19]  W. Rottbauer,et al.  The bird beak configuration has no adverse effect in a magnetic resonance functional analysis of thoracic stent grafts after traumatic aortic transection. , 2015, Journal of vascular surgery.

[20]  Chun-Ku Chen,et al.  Impact on outcomes by measuring tortuosity with reporting standards for thoracic endovascular aortic repair. , 2014, Journal of vascular surgery.

[21]  Y. Sawa,et al.  Clinical experience with the RELAY NBS PLUS stent–graft for aortic arch pathology , 2014, Surgery Today.

[22]  P. Branchereau,et al.  Improvement in conformability of the latest generation of thoracic stent grafts. , 2013, Journal of vascular surgery.

[23]  J. Steuer,et al.  Outcome of endovascular treatment of traumatic aortic transection. , 2012, Journal of vascular surgery.

[24]  Michael D Dake,et al.  Incidence and outcomes after infolding or collapse of thoracic stent grafts. , 2012, Journal of vascular surgery.

[25]  Bhargav Raman,et al.  Impact of quantitatively determined native thoracic aortic tortuosity on endoleak development after thoracic endovascular aortic repair. , 2011, AJR. American journal of roentgenology.

[26]  Salvatore Pasta,et al.  Computer modeling for the prediction of thoracic aortic stent graft collapse. , 2011, Journal of vascular surgery.

[27]  C. Marty-ané,et al.  Impact of Stent-Graft Development on Outcome of Endovascular Repair of Acute Traumatic Transection of the Thoracic Aorta , 2011, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[28]  J. Mckinsey,et al.  Reporting standards for thoracic endovascular aortic repair (TEVAR). , 2010, Journal of vascular surgery.

[29]  R. Chiesa,et al.  Initial Clinical Experience with the Modified Zenith “Pro-Form” TX2 Thoracic Endograft , 2010, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[30]  Jean Marzelle,et al.  Factors favoring stent-graft collapse after thoracic endovascular aortic repair. , 2010, The Journal of thoracic and cardiovascular surgery.

[31]  Takuya Ueda,et al.  Incomplete endograft apposition to the aortic arch: bird-beak configuration increases risk of endoleak formation after thoracic endovascular aortic repair. , 2010, Radiology.

[32]  D. Moher,et al.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement , 2009, BMJ : British Medical Journal.

[33]  F. Setacci,et al.  Chronic kidney disease classification stratifies mortality risk after elective stent graft repair of the thoracic aorta. , 2009, Journal of vascular surgery.

[34]  A. Fayad Thoracic endovascular stent graft with a bird’s beak sign , 2008, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[35]  D. Altman,et al.  Measuring inconsistency in meta-analyses , 2003, BMJ : British Medical Journal.

[36]  David N. Ranney,et al.  Long-term results of endovascular repair for descending thoracic aortic aneurysms. , 2018, Journal of vascular surgery.

[37]  V. Riambau,et al.  Aortic Arch and Thoracic Aorta Curvature Remodeling after Thoracic Endovascular Aortic Repair. , 2017, Annals of vascular surgery.

[38]  B. Bou-Saïd,et al.  Morphological and stent design risk factors to prevent migration phenomena for a thoracic aneurysm: a numerical analysis. , 2015, Medical engineering & physics.

[39]  Po-Lin Chen,et al.  The impact of bird-beak configuration on aortic remodeling of distal arch pathology after thoracic endovascular aortic repair with the Zenith Pro-Form TX2 thoracic endograft. , 2014, Journal of vascular surgery.

[40]  Yoshiki Sawa,et al.  Mid-term results of endovascular treatment with the Gore TAG device for degenerative descending thoracic aortic aneurysms , 2014, General Thoracic and Cardiovascular Surgery.

[41]  L. Lönn,et al.  Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interve , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.