High‐resolution electromagnetic imaging of the San Andreas Fault in central California

Although there is increasing evidence that fluids may play a significant role in the earthquake rupture process, direct observation of fluids in active fault zones remains difficult. Since the presence of an electrically conducting fluid, such as saline pore water, strongly influences the overall conductivity of crustal rocks, electrical and electromagnetic methods offer great potential for overcoming this difficulty. Here we present and compare results from high-resolution magnetotelluric (MT) profiles across two segments of the San Andreas Fault (SAF) which exhibit very different patterns of seismicity: Parkfield, which has regular small earthquakes and creep events, and in the Carrizo Plain, where the fault is seismically quiescent and apparently locked. In both surveys, electric fields were sampled continuously, with 100 m long dipoles laid end-to-end across the fault. From 100 to 0.1 Hz the data from both profiles are consistent with a two-dimensional (2-D) fault-parallel resistivity model. When both transverse electric and magnetic (TE and TM) mode data are included in the interpretation, narrow ({approximately}300{endash}600 m wide) zones of low resistivity extending to depths of 2{endash}4 km in the core of the fault are required at both locations. However, at Parkfield the conductance (conductivity thickness product) of the anomalous region ismore » an order of magnitude larger than at Carrizo Plain, suggesting much higher concentrations of fluids for the more seismically active Parkfield segment. We also image structural differences between the two segments. At Carrizo Plain, resistive, presumably crystalline, rocks are present on both sides of the fault at depths below 3{endash}4 km. In particular, we clearly image resistive basement extending {approximately}10 km or more east of the SAF, beneath the Elkhorn Hills and Temblor Range. At Parkfield the situation is quite different with a resistive block of Salinian granite west of the fault and an electrically conductive, presumably fluid rich Franciscan complex to the east. It is possible that these structural differences control the difference in mechanical behavior of the fault, either directly by affecting fault strength or indirectly by controlling fluid supply. {copyright} 1999 American Geophysical Union« less

[1]  M. Hubbert,et al.  ROLE OF FLUID PRESSURE IN MECHANICS OF OVERTHRUST FAULTING A REPLY , 1959 .

[2]  W. Ellsworth,et al.  Deep scientific drilling in the San Andreas Fault Zone , 1994 .

[3]  William W Rubey,et al.  ROLE OF FLUID PRESSURE IN MECHANICS OF OVERTHRUST FAULTING I. MECHANICS OF FLUID-FILLED POROUS SOLIDS AND ITS APPLICATION TO OVERTHRUST FAULTING , 1959 .

[4]  Gary D. Egbert,et al.  Robust multiple‐station magnetotelluric data processing , 1997 .

[5]  I. Barnes,et al.  Effect of geologic structure and metamorphic fluids on seismic behavior of the San Andreas fault system in central and northern California , 1975 .

[6]  J. T. Smith,et al.  Rapid inversion of two‐ and three‐dimensional magnetotelluric data , 1991 .

[7]  James P. Evans,et al.  Internal structure and weakening mechanisms of the San Andreas Fault , 1993 .

[8]  J. Sims Geologic map of the San Andreas Fault in the Parkfield 7.5-minute Quadrangle, Monterey and Fresno counties, California , 1990 .

[9]  D. C. Ross Possible correlations of basement rocks across the San Andreas, San Gregorio-Hosgri, and Rinconada-Reliz-King City faults, California , 1984 .

[10]  François Robert,et al.  High-angle reverse faults, fluid-pressure cycling, and mesothermal gold-quartz deposits , 1988 .

[11]  N. Sleep,et al.  Creep, compaction and the weak rheology of major faults , 1992, Nature.

[12]  Gary D. Egbert,et al.  Internal structure of the San Andreas fault at Parkfield, California , 1997 .

[13]  W. Irwin Geology and plate-tectonic development , 1990 .

[14]  T. Madden,et al.  Generalized thin sheet analysis in magnetotellurics: an extension of Price's analysis , 1980 .

[15]  S. Hickman,et al.  Near-field stress and pore pressure observations along the Carrizo Plain segment of the San Andreas fault in California , 1996 .

[16]  Alberto Michelini,et al.  Seismological studies at Parkfield. I. Simultaneous inversion for velocity structure and hypocenters using cubic B-splines parameterization , 1991, Bulletin of the Seismological Society of America.

[17]  Gregory A. Davis,et al.  ROLE OF FLUID PRESSURE IN MECHANICS OF OVERTHRUST FAULTING: DISCUSSION , 1965 .

[18]  R. Mackie,et al.  A magnetotelluric investigation of the San Andreas Fault at Carrizo Plain, California , 1997 .

[19]  James D. Byerlee,et al.  Friction, overpressure and fault normal compression , 1990 .

[20]  S. Solomon,et al.  Microearthquake evidence for extension across the Kane Transform Fault , 1990 .

[21]  Alan D. Chave,et al.  On the estimation of magnetotelluric response functions using the singular value decomposition , 1984 .

[22]  R. Osborne,et al.  Cataclastic rocks of the San Gabriel fault—an expression of deformation at deeper crustal levels in the San Andreas fault zone , 1983 .

[23]  P. Johnson,et al.  Parkfield seismicity: Fluid-driven? , 1995 .

[24]  D. Eberhart‐Phillips,et al.  Surface seismic and electrical methods to detect fluids related to faulting , 1995 .

[25]  Alan D. Chave,et al.  On electric and magnetic galvanic distortion tensor decompositions , 1994 .

[26]  R. Mackie,et al.  Magnetotelluric evidence for crustal suture zones bounding the Southern Great Valley, California , 1991 .

[27]  T. Dibblee Regional geologic map of San Andreas and related faults in Carrizo Plain, Temblor, Caliente, and La Panza Ranges and vicinity, California , 1973 .

[28]  M. Zoback,et al.  New Evidence on the State of Stress of the San Andreas Fault System , 1987, Science.

[29]  Stephen K. Park,et al.  Sensitivity of the telluric monitoring array in Parkfield, California, to changes of resistivity , 1990 .

[30]  W. H. Bakun,et al.  The Parkfield, California, Earthquake Prediction Experiment , 1985, Science.

[31]  T. D. Gamble magnetotellurics with a remote reference , 1979 .

[32]  W. Mooney,et al.  Two-dimensional velocity structure along the synclinal axis of the Great Valley, California , 1986 .

[33]  J. Brune,et al.  Heat Flow, Stress, and Rate of Slip along the San Andreas Fault, , 1969 .

[34]  J. Byerlee,et al.  Model for episodic flow of high-pressure water in fault zones before earthquakes , 1993 .

[35]  John Clarke,et al.  Magnetotellurics with a remote magnetic reference , 1979 .

[36]  A. Michael,et al.  Three‐dimensional velocity structure, seismicity, and fault structure in the Parkfield Region, central California , 1993 .

[37]  G. Egbert,et al.  Robust estimation of geomagnetic transfer functions , 1986 .

[38]  A. Thomson,et al.  Tectonically controlled fan delta and submarine fan sedimentation of late Miocene age, southern Temblor Range, California , 1989 .

[39]  T. Dibblee Stratigraphy of the southern coast ranges near the San Andreas Fault from Cholame to Maricopa, California , 1973 .

[40]  Carlos Torres-Verdín,et al.  Principles of spatial surface electric field filtering in magnetotellurics; electromagnetic array profiling (EMAP) , 1992 .

[41]  Gerald W. Hohmann,et al.  Magnetotelluric responses of three-dimensional bodies in layered earths , 1982 .

[42]  W Foxall,et al.  Clustering and Periodic Recurrence of Microearthquakes on the San Andreas Fault at Parkfield, California , 1995, Science.

[43]  Randall L. Mackie,et al.  Long-Period Magnetotelluric Measurements Near the Central California Coast: A Land-Locked View of the Conductivity Structure Under the Pacific Ocean , 1988 .

[44]  A. Lachenbruch,et al.  Frictional heating, fluid pressure, and the resistance to fault motion , 1980 .