Simplified and Efficient Quantification of Low-abundance Proteins at Very High Multiplex via Targeted Mass Spectrometry*

Liquid chromatography–multiple reaction monitoring mass spectrometry (LC-MRM-MS) of plasma that has been depleted of abundant proteins and fractionated at the peptide level into six to eight fractions is a proven method for quantifying proteins present at low nanogram-per-milliliter levels. A drawback of fraction-MRM is the increased analysis time due to the generation of multiple fractions per biological sample. We now report that the use of heated, long, fused silica columns (>30 cm) packed with 1.9 μm of packing material can reduce or eliminate the need for fractionation prior to LC-MRM-MS without a significant loss of sensitivity or precision relative to fraction-MRM. We empirically determined the optimal column length, temperature, gradient duration, and sample load for such assays and used these conditions to study detection sensitivity and assay precision. In addition to increased peak capacity, longer columns packed with smaller beads tolerated a 4- to 6-fold increase in analyte load without a loss of robustness or reproducibility. The longer columns also provided a 4-fold improvement in median limit-of-quantitation values with increased assay precision relative to the standard 12 cm columns packed with 3 μm material. Overall, the optimized chromatography provided an approximately 3-fold increase in analysis throughput with excellent robustness and less than a 2-fold reduction in quantitative sensitivity relative to fraction-MRM. The value of the system for increased multiplexing was demonstrated by the ability to configure an 800-plex MRM-MS assay, run in a single analysis, comprising 2400 transitions with retention time scheduling to monitor 400 unlabeled and heavy labeled peptide pairs.

[1]  Ronald J. Moore,et al.  Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum , 2012, Proceedings of the National Academy of Sciences.

[2]  Brendan MacLean,et al.  Bioinformatics Applications Note Gene Expression Skyline: an Open Source Document Editor for Creating and Analyzing Targeted Proteomics Experiments , 2022 .

[3]  D R Mani,et al.  Interlaboratory Evaluation of Automated, Multiplexed Peptide Immunoaffinity Enrichment Coupled to Multiple Reaction Monitoring Mass Spectrometry for Quantifying Proteins in Plasma* , 2011, Molecular & Cellular Proteomics.

[4]  Ludovic C. Gillet,et al.  Quantitative measurements of N‐linked glycoproteins in human plasma by SWATH‐MS , 2013, Proteomics.

[5]  Susan E Abbatiello,et al.  Automated detection of inaccurate and imprecise transitions in peptide quantification by multiple reaction monitoring mass spectrometry. , 2010, Clinical chemistry.

[6]  M. Imieliński,et al.  In Situ Proteomic Analysis of Human Breast Cancer Epithelial Cells Using Laser Capture Microdissection: Annotation by Protein Set Enrichment Analysis and Gene Ontology* , 2010, Molecular & Cellular Proteomics.

[7]  Jeffrey R. Whiteaker,et al.  Peptide immunoaffinity enrichment coupled with mass spectrometry for peptide and protein quantification. , 2011, Clinics in laboratory medicine.

[8]  Amanda G. Paulovich,et al.  An Automated and Multiplexed Method for High Throughput Peptide Immunoaffinity Enrichment and Multiple Reaction Monitoring Mass Spectrometry-based Quantification of Protein Biomarkers* , 2009, Molecular & Cellular Proteomics.

[9]  M. Mann,et al.  Deep and Highly Sensitive Proteome Coverage by LC-MS/MS Without Prefractionation* , 2011, Molecular & Cellular Proteomics.

[10]  M. Mann,et al.  System-wide Perturbation Analysis with Nearly Complete Coverage of the Yeast Proteome by Single-shot Ultra HPLC Runs on a Bench Top Orbitrap* , 2011, Molecular & Cellular Proteomics.

[11]  S. Carr,et al.  Quantitative analysis of peptides and proteins in biomedicine by targeted mass spectrometry , 2013, Nature Methods.

[12]  Michael S. Bereman,et al.  Effects of Column and Gradient Lengths on Peak Capacity and Peptide Identification in Nanoflow LC-MS/MS of Complex Proteomic Samples , 2012, Journal of The American Society for Mass Spectrometry.

[13]  Ronald J Moore,et al.  Long-gradient separations coupled with selected reaction monitoring for highly sensitive, large scale targeted protein quantification in a single analysis. , 2013, Analytical chemistry.

[14]  Xu Shi,et al.  Quantification of Cardiovascular Biomarkers in Patient Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution* , 2009, Molecular & Cellular Proteomics.

[15]  D R Mani,et al.  Developing multiplexed assays for troponin I and interleukin-33 in plasma by peptide immunoaffinity enrichment and targeted mass spectrometry. , 2009, Clinical chemistry.

[16]  S. Carr,et al.  Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution*S , 2007, Molecular & Cellular Proteomics.

[17]  S. Carr,et al.  A pipeline that integrates the discovery and verification of plasma protein biomarkers reveals candidate markers for cardiovascular disease , 2011, Nature Biotechnology.

[18]  Pei Wang,et al.  A targeted proteomics–based pipeline for verification of biomarkers in plasma , 2011, Nature Biotechnology.

[19]  J. W. Finch,et al.  Effects of column length, particle size, gradient length and flow rate on peak capacity of nano-scale liquid chromatography for peptide separations. , 2007, Journal of chromatography. A.

[20]  G. Desmet,et al.  Comparison of the gradient kinetic performance of silica monolithic capillary columns with columns packed with 3 μm porous and 2.7 μm fused-core silica particles. , 2012, Journal of chromatography. A.

[21]  D. Clicq,et al.  Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology. , 2005, Analytical chemistry.

[22]  Jarrett D. Egertson,et al.  Multiplexed MS/MS for Improved Data Independent Acquisition , 2013, Nature Methods.

[23]  J. Gebler,et al.  Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography. , 2004, Journal of chromatography. A.

[24]  P. Sandra,et al.  The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation. , 2010, Journal of chromatography. A.