Integrating Morphological Edge Detection and Mutual Information for Nonrigid Registration of Medical Images.

BACKGROUND Medical images are widely used within healthcare and medical research. There is an increased interest in precisely correlating information in these images through registration techniques for investigative and therapeutic purposes. This work proposes and evaluates an improved measure function for registration of carotid ultrasound and magnetic resonance images (MRI) taken at different times. METHODS To achieve this, a morphological edge detection operator has been designed to extract the vital edge information from images which is integrated with the Mutual Information (MI) to carry out the registration process. The improved performance of proposed registration measure function is demonstrated using four quality metrics: Correlation Coefficient (CC), Structural Similarity Index (SSIM), Visual Information Fidelity (VIF) and Gradient Magnitude Similarity Deviation (GMSD). The qualitative validation has also been done through visual inspection of the registered image pairs by clinical radiologists. RESULTS The experimental results showed that the proposed method outperformed the existing method (based on integrated MI and standard edge detection) for both ultrasound and MR images in terms of CC by about 4.67%, SSIM by 3.21%, VIF by 18.5%, and decreased GMSD by 37.01%. Whereas, in comparison to the standard MI based method, the proposed method has increased CC by 16.29%, SSIM by 16.13%, VIF by 52.56% and decreased GMSD by 66.06%, approximately. CONCLUSION Thus, the proposed method improves the registration accuracy when the original images are corrupted by noise, have low intensity values or missing data.

[1]  M. Viergever,et al.  Medical image matching-a review with classification , 1993, IEEE Engineering in Medicine and Biology Magazine.

[2]  Zhongguo Liu,et al.  Medical Image Registration by Maximization of Combined Mutual Information and Edge Correlative Deviation , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[3]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[4]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[5]  U. Bayraktutan,et al.  Epidemiology, pathophysiology, and treatment of hypertension in ischaemic stroke patients. , 2013, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association.

[6]  W. Kerwin,et al.  The vulnerable, or high-risk, atherosclerotic plaque: noninvasive MR imaging for characterization and assessment. , 2007, Radiology.

[7]  Savita Gupta,et al.  A hybrid framework for registration of carotid ultrasound images combining iconic and geometric features , 2013, Medical & Biological Engineering & Computing.

[8]  Gerrit L ten Kate,et al.  Noninvasive imaging of the vulnerable atherosclerotic plaque. , 2010, Current problems in cardiology.

[9]  Nassir Navab,et al.  Vascular image registration techniques: A living review , 2017, Medical Image Anal..

[10]  D. Hill,et al.  Medical image registration , 2001, Physics in medicine and biology.

[11]  Jong Beom Ra,et al.  Multi-sensor image registration based on intensity and edge orientation information , 2008, Pattern Recognit..

[12]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[13]  Max A. Viergever,et al.  A survey of medical image registration - under review , 2016, Medical Image Anal..

[14]  Nicholas Ayache,et al.  Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information , 2001, IEEE Transactions on Medical Imaging.

[15]  Chun Yuan,et al.  Clinical factors associated with high-risk carotid plaque features as assessed by magnetic resonance imaging in patients with established vascular disease (from the AIM-HIGH Study). , 2014, The American journal of cardiology.

[16]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[17]  C. Lawrence Zitnick,et al.  Fast Edge Detection Using Structured Forests , 2014, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[18]  Jan Flusser,et al.  Image registration methods: a survey , 2003, Image Vis. Comput..

[19]  Aaron Fenster,et al.  Nonrigid registration of three-dimensional ultrasound and magnetic resonance images of the carotid arteries. , 2009, Medical physics.

[20]  Gary Friday,et al.  2011 ASA/ACCF/AHA/AANN/AANS/ACR/ASNR/CNS/SAIP/SCAI/SIR/SNIS/SVM/SVS guideline on the management of patients with extracranial carotid and vertebral artery disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, and the American , 2011, Journal of the American College of Cardiology.

[21]  Gary Friday,et al.  2011 ASA/ACCF/AHA/AANN/AANS/ACR/ASNR/CNS/SAIP/SCAI/SIR/SNIS/SVM/SVS guideline on the management of patients with extracranial carotid and vertebral artery disease: executive summary , 2011, Journal of NeuroInterventional Surgery.

[22]  Max A. Viergever,et al.  Image Registration by Maximization of Combined Mututal Information and Gradient Information , 2000, MICCAI.

[23]  Lei Yang,et al.  An improved Prewitt algorithm for edge detection based on noised image , 2011, 2011 4th International Congress on Image and Signal Processing.

[24]  Guy Marchal,et al.  Multi-modality image registration by maximization of mutual information , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.

[25]  D Marr,et al.  Theory of edge detection , 1979, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[26]  B. Lal,et al.  Carotid plaque morphometric assessment with three-dimensional ultrasound imaging. , 2015, Journal of vascular surgery.

[27]  Paul A. Viola,et al.  Multi-modal volume registration by maximization of mutual information , 1996, Medical Image Anal..

[28]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[29]  A Fenster,et al.  Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries. , 2001, Ultrasound in medicine & biology.

[30]  Alan C. Bovik,et al.  Image information and visual quality , 2006, IEEE Trans. Image Process..

[31]  Lei Zhang,et al.  Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index , 2013, IEEE Transactions on Image Processing.

[32]  Ahmed Atwan,et al.  Current trends in medical image registration and fusion , 2016 .