Flicker mitigation in DFIG wind turbine systems

This paper presents an approach that mitigates the flicker in doubly-fed induction generator (DFIG) wind turbine systems. The reactive power is controlled to compensate for the flicker from the grid-side converter (GSC). However, it is not sufficient to eliminate the flicker fully in the case of the low grid impedance ratio and the limited capacity of converters. So, a method using an energy storage system (ESS) for the output power smoothening is combined with the reactive power control to reduce the flicker. The PSCAD/EMTDC simulation results show the effectiveness of the proposed method for a 2[MW] DFIG wind turbine system.

[1]  M. Chinchilla,et al.  Laboratory set-up for wind turbine emulation , 2004, 2004 IEEE International Conference on Industrial Technology, 2004. IEEE ICIT '04..

[2]  P. Marino,et al.  Improved and extended DG capability in voltage regulation by reactive and active power , 2007, 2007 International Conference on Power Engineering, Energy and Electrical Drives.

[3]  F. Blaabjerg,et al.  Flicker study on variable speed wind turbines with doubly fed induction generators , 2005, IEEE Transactions on Energy Conversion.

[4]  A. Zuccato,et al.  Electromagnetic compatibility issues in industrial equipment , 1999 .

[5]  Dong-Jun Won,et al.  Mitigation of the Flicker Level of a DFIG Using Power Factor Angle Control , 2009, IEEE Transactions on Power Delivery.

[6]  J. Usaola,et al.  Propagation of Flicker in Electric Power Networks Due to Wind Energy Conversions Systems , 2002, IEEE Power Engineering Review.

[7]  J. Schlabbach,et al.  Voltage Quality in Electrical Power Systems , 2001 .

[8]  Dong-Choon Lee,et al.  Developing Function Models of Back-to-Back PWM Converters for Simplified Simulation , 2011 .

[9]  B. Dakyo,et al.  Large Band Simulation of the Wind Speed for Real-Time Wind Turbine Simulators , 2002, IEEE Power Engineering Review.

[10]  Frede Blaabjerg,et al.  Flicker mitigation of grid connected wind turbines using STATCOM , 2004 .

[11]  A. Larsson,et al.  Flicker Emission of Wind Turbines during Continuous Operation , 2002, IEEE Power Engineering Review.

[12]  G. Gerdes,et al.  Power quality of wind turbines and their interaction with the grid , 1995 .

[13]  Dong-Choon Lee,et al.  LVRT and power smoothening of DFIG-based wind turbine systems using energy storage devices , 2010, ICCAS 2010.

[14]  D. J. Atkinson,et al.  Use of Load Control to Regulate Voltage on Distribution Networks with Embedded Generation , 2002, IEEE Power Engineering Review.

[15]  V. Akhmatov Analysis of Dynamic Behaviour of Electric Power Systems with Large Amount of Wind Power , 2003 .

[16]  Zbigniew Lubosny,et al.  Wind Turbine Operation in Electric Power Systems , 2003 .