A comparison of fast spin echo and gradient field echo sequences.

Optimal angle, fast repeat time, gradient field echo imaging techniques such as FISP (Fast Imaging with Steady Precession) and FLASH (Fast Low Angle Shot) often fail to discriminate disease from healthy tissue for two main reasons. First, T1 and T2 of the affected tissue may increase such that the ratio of T1 to T2 remains nearly unchanged, hence there is no contrast change with FISP. Second, T2 weighted gradient field echo images suffer severely from T2* signal and resolution loss leading to a reduction in C/N. Although FLASH imaging with two separate angles can, in principle, extract the longer T1 tumors, contrast is often not good. To overcome the inhomogeneity and contrast problems, we have implemented a FAst optimal angle spin-echo sequence with a short TE(FATE). For the first echo, FATE has the same contrast properties as FLASH with a slight decrease in signal intensity. The advantage is that the intensity of the signal does not suffer from T2* signal decay, hence improved contrast and disease detection via T2 weighted FATE images is possible. Contrast-to-noise in lesion detection is also considered for CE FAST (Contrast Enhanced Fast), a T2-weighted version of FISP, and HYBRID.

[1]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[2]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[3]  J. B. Kneeland,et al.  Maximizing signal-to-noise and contrast-to-noise ratios in FLASH imaging. , 1987, Magnetic resonance imaging.

[4]  J. Carlson,et al.  Partial flip angle MR imaging. , 1987, Radiology.

[5]  P A Bottomley,et al.  Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging , 1983, Journal of computer assisted tomography.

[6]  Jens Frahm,et al.  Transverse coherence in rapid FLASH NMR imaging , 1987 .

[7]  Peter Mansfield,et al.  BIOLOGICAL AND MEDICAL IMAGING BY NMR , 1978 .

[8]  G. Bydder,et al.  MRI: The development of T2 contrast with rapid field echo sequences , 1987, Magnetic resonance in medicine.

[9]  E M Haacke,et al.  Reduction of MR imaging time by the hybrid fast-scan technique. , 1986, Radiology.

[10]  W. Edelstein,et al.  The intrinsic signal‐to‐noise ratio in NMR imaging , 1986, Magnetic resonance in medicine.

[11]  R R Edelman,et al.  Contrast in rapid MR imaging: T1- and T2-weighted imaging. , 1987, Journal of computer assisted tomography.

[12]  R. R. Ernst,et al.  Application of Fourier Transform Spectroscopy to Magnetic Resonance , 1966 .

[13]  W. Edelstein,et al.  Surface‐coil T1 images , 1986, Magnetic resonance in medicine.

[14]  D Matthaei,et al.  Rapid three-dimensional MR imaging using the FLASH technique. , 1986, Journal of computer assisted tomography.

[15]  S. Patz,et al.  Rapid Fourier imaging using steady‐state free precession , 1987, Magnetic resonance in medicine.

[16]  A. Shimakawa,et al.  Chemical shift-induced amplitude modulations in images obtained with gradient refocusing. , 1987, Magnetic resonance imaging.

[17]  J. Waugh Sensitivity in Fourier transform NMR spectroscopy of slowly relaxing systems , 1970 .

[18]  W. Hinshaw,et al.  Image formation by nuclear magnetic resonance: The sensitive‐point method , 1976 .

[19]  C. Hardy,et al.  A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic? , 1987, Medical physics.

[20]  I. Young,et al.  Variations in slice shape and absorption as artifacts in the determination of tissue parameters in NMR imaging , 1985, Magnetic resonance in medicine.

[21]  M. Gyngell Steady-state free precession sequences , 1987 .

[22]  A new method of measuring T2 using steady-state free precession , 1985 .

[23]  D. Thomas,et al.  Clinical use of rapid T2 weighted partial saturation sequences in MR imaging. , 1987, Journal of computer assisted tomography.

[24]  R. Freeman,et al.  Phase and intensity anomalies in fourier transform NMR , 1971 .

[25]  A. Haase,et al.  Flow suppression in rapid FLASH NMR images , 1987, Magnetic resonance in medicine.

[26]  H. Carr STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE , 1958 .

[27]  D Wyper,et al.  MR Relaxation Times of Cerebrospinal Fluid , 1987, Journal of computer assisted tomography.