The effect of endovascular aortic stents placed across the renal arteries.

OBJECTIVES To investigate renal artery patency and renal function after deployment of aortic stents covering the orifices of renal arteries. DESIGN Prospective open animal study. SETTING Department of Experimental Surgery at a university hospital. MATERIALS Twenty-three pigs were used. METHODS Ten pigs were observed for 1 h after graft-anchoring aortic stents, Gianturco (5) and Palmaz (5), were placed so that the stents covered the renal arterial orifices. In 13 pigs, Gianturco (6) and Palmaz (7) stents without grafts were placed over the renal arteries and left in situ for 7 days. Renal function and blood flow were measured by renograms, iohexol clearance and ultrasonic blood flow meter and patency was verified by angiograms. The kidneys were microscopically examined for signs of ischaemia and microemboli. RESULTS One renal artery covered by a graft-anchoring Gianturco stent occluded. The remaining renal arteries remained patent without any significant decrease in renal blood flow after stent deployment. Normal renal function and histology was maintained. CONCLUSIONS Aortic stents placed at the level of the renal arteries do not affect renal blood flow within 1 week in this experimental model. This may prove valuable in endovascular treatment of aortic aneurysms and in other procedures involving stents.

[1]  G. Gardiner,et al.  Palmaz vascular stent: initial clinical experience. , 1990, Radiology.

[2]  C. Dotter,et al.  Transluminally-placed coilspring endarterial tube grafts. Long-term patency in canine popliteal artery. , 1969, Investigative radiology.

[3]  R. Virmani,et al.  Flexible tantalum stents implanted in aortas and iliac arteries: effects in normal canines. , 1990, Radiology.

[4]  L. Norgren,et al.  Thrombogenicity of metallic vascular stents in arteries and veins--an experimental study in pigs. , 1990, European journal of vascular surgery.

[5]  J. Palmaz,et al.  Early endothelisation of balloon-expandable stents: experimental observations , 1988 .

[6]  J. Palmaz,et al.  Placement of balloon-expandable intraluminal stents in iliac arteries: first 171 procedures. , 1990, Radiology.

[7]  L. Jacobsson,et al.  The use of iohexol clearance to determine GFR in patients with severe chronic renal failure--a comparison between different clearance techniques. , 1995, Clinical nephrology.

[8]  J. Palmaz,et al.  Intravascular stents: tissue-stent interactions and design considerations. , 1993, AJR. American journal of roentgenology.

[9]  J. Gaux,et al.  Percutaneous iliac artery stent: angiographic long-term follow-up. , 1991, Radiology.

[10]  W. Baxley,et al.  Vascular pathology of balloon-expandable flexible coil stents in humans. , 1992, Journal of the American College of Cardiology.

[11]  J. Palmaz,et al.  Balloon-expandable intravascular stent. , 1988, AJR. American journal of roentgenology.

[12]  P. J. Martin,et al.  Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate. , 1986, British medical journal.

[13]  R. Green,et al.  Infrarenal aortic aneurysm structure: implications for transfemoral repair. , 1994, Journal of vascular surgery.

[14]  J. Parodi,et al.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms , 1991, Annals of vascular surgery.

[15]  R. Green,et al.  Transfemoral endovascular aortic graft placement. , 1993, Journal of vascular surgery.

[16]  J. May,et al.  Results of endoluminal grafting of abdominal aortic aneurysms are dependent on aneurysm morphology , 1996, Annals of vascular surgery.

[17]  J. Parodi Endovascular repair of abdominal aortic aneurysms and other arterial lesions. , 1995, Journal of vascular surgery.

[18]  S. Hanson,et al.  Reduction in Thrombus Formation by Placement of Endovascular Stents at Endarterectomy Sites in Baboon Carotid Arteries , 1991, Circulation.

[19]  K. Ouriel Intraluminal bypass of abdominal aortic aneurysm: Feasibility study , 1993 .

[20]  P. Serruys,et al.  Histology after stenting of human saphenous vein bypass grafts: observations from surgically excised grafts 3 to 320 days after stent implantation. , 1993, Journal of the American College of Cardiology.

[21]  J. Palmaz,et al.  Intraluminal stents in atherosclerotic iliac artery stenosis: preliminary report of a multicenter study. , 1988, Radiology.

[22]  E. Mattsson,et al.  Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study. , 1993, Clinical physiology.

[23]  G. Becker Intravascular Stents: General Principles and Status of Lower‐Extremity Arterial Applications , 1991, Circulation.

[24]  N L Volodos,et al.  Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. , 1991, VASA. Supplementum.

[25]  P. Anthony Robbins' Pathologic Basis of Disease , 1990 .