Trends and outcomes in transcatheter aortic valve implantation in Belgium: a 13-year single centre experience

Abstract Background Transcatheter aortic valve implantation (TAVI) has been adopted as an alternative to surgery in severe aortic stenosis treatment, even in low-intermediate risk. The aim of this study is to retrospectively report our single-centre 13-year TAVI experience with emphasis on learning curve, referral indication and trends in outcomes over time. Methods We included 361 consecutive patients who underwent TAVI from January 2008 to December 2020, grouped according to similar per-year volume of procedures: G1 (2008–2014), G2 (2015–2017) and G3 (2018–2020). Results The number of procedures increased (group size: 59 vs. 106 vs. 196). No major differences were observed in STS-PROM and EuroSCORE-II between groups, despite TAVI in patients with prior surgical revascularisation was mainly performed in G1. Trans-femoral approach raised from 80.8 to 93.4%, while the most common alternative access was trans-subclavian. The pre-dilation rate was higher in G1 with lower prosthesis post-dilation rate. The length of hospital stay decreased in time by 30%. At 30 days a reduction in all-cause mortality, vascular complications, bleedings and para-valvular leak combined with higher rate of permanent pacing were observed over the groups. At 1-year there was no difference in all-cause mortality but over 30% reduction in cardiovascular death (8.5 vs. 7.5 vs. 5.6%). Conclusions Favourable trends were observed across the groups, with an improvement in periprocedural outcomes and cardiovascular mortality at 1-year. These improvements could depend on increased expertise because mortality reduction was noted only after reaching a significant procedure volume. A trend towards lower risk patients selection was present in our cohort, as previously described worldwide.

[1]  A. Rück,et al.  Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: SWEDEHEART Observational Study. , 2021, JACC. Cardiovascular interventions.

[2]  B. Prendergast,et al.  2021 ESC/EACTS Guidelines for the management of valvular heart disease. , 2021, European heart journal.

[3]  J. Leipsic,et al.  Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research. , 2021, European heart journal.

[4]  Lin Cai,et al.  The Relation between Volume and Outcome of Transcatheter and Surgical Aortic Valve Replacement: A Systematic Review and Meta-Analysis , 2020, Cardiovascular therapeutics.

[5]  C. Bode,et al.  Outcomes of transcatheter aortic valve implantations in high-volume or low-volume centres in Germany , 2020, Heart.

[6]  M. Kofler,et al.  Balloon-expandable transcatheter aortic valve implantation with or without pre-dilation – results of a meta-analysis of 3 multicenter registries , 2019, BMC Cardiovascular Disorders.

[7]  J. Leipsic,et al.  Transcatheter Aortic‐Valve Replacement with a Balloon‐Expandable Valve in Low‐Risk Patients , 2019, The New England journal of medicine.

[8]  P. Wenaweser,et al.  Temporal Trends in Adoption and Outcomes of Transcatheter Aortic Valve Implantation: A Swisstavi Registry Analysis. , 2018, European heart journal. Quality of care & clinical outcomes.

[9]  B. Carabello,et al.  Aortic stenosis , 2018, Rapid Cardiac Care.

[10]  Sean M. O'Brien,et al.  The Society of Thoracic Surgeons 2018 Adult Cardiac Surgery Risk Models: Part 1-Background, Design Considerations, and Model Development. , 2018, The Annals of thoracic surgery.

[11]  E. Tuzcu,et al.  Current Society of Thoracic Surgeons Model Reclassifies Mortality Risk in Patients Undergoing Transcatheter Aortic Valve Replacement , 2018, Circulation. Cardiovascular interventions.

[12]  T. Walther,et al.  Transfemoral aortic valve implantation using a self-expanding transcatheter heart valve without pre-dilation. , 2017, International journal of cardiology.

[13]  W. Vach,et al.  Learning Curves Among All Patients Undergoing Transcatheter Aortic Valve Implantation in Germany: A Retrospective Observational Study. , 2017, International journal of cardiology.

[14]  Andrew S. Mugglin,et al.  Surgical or Transcatheter Aortic‐Valve Replacement in Intermediate‐Risk Patients , 2017, The New England journal of medicine.

[15]  I. Barbash,et al.  Temporal trends in transcatheter aortic valve implantation, 2008–2014: patient characteristics, procedural issues, and clinical outcome , 2017, Clinical cardiology.

[16]  N. Van Mieghem,et al.  TAVI with current CE-marked devices: strategies for optimal sizing and valve delivery. , 2016, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[17]  L. Wilkins Transcatheter Aortic Valve Implantation With or Without Preimplantation Balloon Aortic Valvuloplasty: A Systematic Review and Meta‐Analysis , 2016, Journal of the American Heart Association.

[18]  A. Cribier,et al.  Trends over the past 4 years in population characteristics, 30-day outcomes and 1-year survival in patients treated with transcatheter aortic valve implantation. , 2016, Archives of cardiovascular diseases.

[19]  M. Mack,et al.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. , 2016, The New England journal of medicine.

[20]  D. Tousoulis,et al.  Atrial Fibrillation During or After TAVI: Incidence, Implications and Therapeutical Considerations. , 2016, Current pharmaceutical design.

[21]  M. Toyofuku,et al.  Initial Surgical Versus Conservative Strategies in Patients With Asymptomatic Severe Aortic Stenosis. , 2015, Journal of the American College of Cardiology.

[22]  R. Lange,et al.  Perioperative Results and Complications in 15,964 Transcatheter Aortic Valve Replacements: Prospective Data From the GARY Registry. , 2015, Journal of the American College of Cardiology.

[23]  L. W. Andersen,et al.  Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial. , 2015, Journal of the American College of Cardiology.

[24]  N. Moat,et al.  Device-dependent association between paravalvar aortic regurgitation and outcome after TAVI , 2014, Heart.

[25]  C. Vrints,et al.  Hospitalization costs of TAVI in one Belgian university hospital , 2013, Acta cardiologica.

[26]  B. Prendergast,et al.  The 2011-12 pilot European Sentinel Registry of Transcatheter Aortic Valve Implantation: in-hospital results in 4,571 patients. , 2013, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[27]  P. Serruys,et al.  Trends in outcome after transfemoral transcatheter aortic valve implantation. , 2013, American heart journal.

[28]  Jennifer Taylor,et al.  ESC/EACTS Guidelines on the management of valvular heart disease. , 2012, European heart journal.

[29]  D. Wood,et al.  Transcatheter aortic valve implantation , 2010, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[30]  Sean M. O'Brien,et al.  The Society of Thoracic Surgeons 2008 cardiac surgery risk models: part 2--isolated valve surgery. , 2009, The Annals of thoracic surgery.

[31]  J. Gardin,et al.  Burden of valvular heart diseases: a population-based study , 2006, The Lancet.

[32]  Philippe Ravaud,et al.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. , 2003, European heart journal.

[33]  Assaf Bash,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis: First Human Case Description , 2002, Circulation.

[34]  J. Heikkilä,et al.  Prevalence of aortic valve abnormalities in the elderly: an echocardiographic study of a random population sample. , 1993, Journal of the American College of Cardiology.

[35]  Franz Schwarz,et al.  The Effect of Aortic Valve Replacement on Survival , 1982, Circulation.

[36]  R. Khouzam,et al.  Permanent pacemaker insertion in patients with conduction abnormalities post transcatheter aortic valve replacement: a review and proposed guidelines. , 2018, Annals of translational medicine.