Effect of operating conditions on excitation temperature and electron number density in axially-viewed ICP-OES with introduction of vapours or aerosols

The combined effect of the power and the carrier gas flow rate on excitation temperature, electron number density, ionic-to-atomic line intensity ratios and departure from local thermal equilibrium has been studied in an axially-viewed plasma with introduction of different amounts of wet aerosols, partially desolvated aerosols or dry vapours, according to empirical modelling and experimental design methods. Under robust conditions (1500 W and a carrier gas flow rate of 0.7–0.85 L min−1), an increase in water loading led to an improvement in the plasma excitation properties, while desolvation caused degradation. In contrast, under non-robust conditions, the plasma was no longer able to tolerate an increase in water loading and desolvation resulted in an improvement in the plasma characteristics. The hydrogen formed during the hydride generation process significantly improved the plasma excitation properties, regardless of the conditions. In this instance, the plasma characteristics were primarily affected by the reductant concentration, which determined the amount of hydrogen generated, and by the carrier gas flow rate, which controlled its residence time within the plasma. In contrast, there was no relevant change in the plasma excitation conditions due to systematic variation of HCl concentration from 0.1 to 6 M.

[1]  M. Grotti,et al.  Multivariate study in chemical vapor generation for simultaneous determination of arsenic, antimony, bismuth, germanium, tin, selenium, tellurium and mercury by inductively coupled plasma optical emission spectrometry , 2005 .

[2]  M. Grotti,et al.  Multivariate optimization of an axially-viewed inductively coupled plasma multichannel-based emission spectrometer for the analysis of environmental samples. , 2005, Annali di chimica.

[3]  R. Leardi,et al.  Combined effects of inorganic acids in inductively coupled plasma optical emission spectrometry , 2002 .

[4]  J. Mermet,et al.  Study of ionic-to-atomic line intensity ratios for two axial viewing-based inductively coupled plasma atomic emission spectrometers , 2001 .

[5]  M. Grotti,et al.  Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization , 2000 .

[6]  G. Hieftje,et al.  Characterization of a 22 mm Torch for ICP-AES , 1999 .

[7]  J. Mermet,et al.  Comparison of the effect of acetic acid with axially and radially viewed inductively coupled plasma atomic emission spectrometry: influence of the operating conditions , 1998 .

[8]  I. Brenner,et al.  Ca and Na interference effects in an axially viewed ICP using low and high aerosol loadings , 1998 .

[9]  J. Mermet,et al.  Minimization of acid effects at low consumption rates in an axially viewed inductively coupled plasma atomic emission spectrometer by using micronebulizer-based sample introduction systems , 1998 .

[10]  B. Budic Matrix effects in inductively coupled plasma atomic emission spectrometry using an ultrasonic nebulizer , 1998 .

[11]  G. Hieftje,et al.  Comparison of electron concentrations, electron temperatures, gas kinetic temperatures, and excitation temperatures in argon ICPs operated at 27 and 40 MHz , 1997 .

[12]  J. Mermet,et al.  The effect of sodium on analyte ionic line intensities in inductively coupled plasma atomic emission spectrometry : influence of the operating conditions , 1997 .

[13]  Paul J. Galley,et al.  An imaging-based instrument for fundamental plasma studies , 1997 .

[14]  J. Mermet,et al.  Comparison of axially and radially viewed inductively coupled plasma atomic emission spectrometry in terms of signal-to-background ratio and matrix effects , 1997 .

[15]  I. Brenner,et al.  Comparison of Axially and Radially Viewed Inductively CoupledPlasmas for Multi-element Analysis: Effect of Sodium andCalcium , 1997 .

[16]  Jia Wan,et al.  Effect of power and carrier gas flow rate on the tolerance to water loading in inductively coupled plasma atomic emission spectrometry , 1996 .

[17]  J. Tyson,et al.  Performance evaluation of an axially viewed horizontal inductively coupled plasma for optical emission spectrometry , 1995 .

[18]  A. Canals,et al.  Fundamental studies on pneumatic generation and aerosol transport in atomic spectrometry : effect of mineral acids on emission intensity in inductively coupled plasma atomic emission spectrometry , 1995 .

[19]  I. Brenner,et al.  Effect of nitric and hydrochloric acids on rare earth element (REE) intensities in inductively coupled plasma emission spectrometry , 1995 .

[20]  Norman N. Sesi,et al.  The effect of sample matrix on electron density, electron temperature and gas temperature in the argon inductively coupled plasma examined by Thomson and Rayleigh scattering , 1994 .

[21]  N. Carrión,et al.  Influence of operating conditions on the effects of acids in inductively coupled plasma atomic emission spectrometry , 1994 .

[22]  I. Holclajtner-Antunović,et al.  Study of the matrix effect of easily and non-easily ionizable elements in an inductively coupled argon plasma. Part 1. Spectroscopic diagnostics , 1993 .

[23]  X. Jian,et al.  Matrix effects of easily ionized elements on the spatial distribution of electron number densities in an inductively coupled plasma using an optical fibre probe and a photodiode array spectrometer , 1992 .

[24]  E. Yoshimura,et al.  Interference by mineral acids in inductively coupled plasma atomic emission spectrometry , 1990 .

[25]  J. Mermet Ionic to atomic line intensity ratio and residence time in inductively coupled plasma-atomic emission spectrometry , 1989 .

[26]  P. Boumans Detection limits for lines widely differing in “hardness” and intensity ratios of ionic to atomic lines measured in 50 and 100 MHz inductively coupled plasmas , 1989 .

[27]  D. Schram,et al.  Electron density and temperature determination in an ICP using a non-equilibrium concept , 1988 .

[28]  C. Trassy,et al.  Inductively coupled plasma: the role of water in axial excitation temperatures , 1986 .

[29]  M. Blades,et al.  Analyte ionization in the inductively coupled plasma , 1985 .

[30]  D. R. Demers Evaluation of the Axially Viewed (End-on) Inductively Coupled Argon Plasma Source for Atomic Emission Spectroscopy , 1979 .

[31]  D. J. Kalnicky,et al.  Excitation Temperatures and Electron Number Densities Experienced by Analyte Species in Inductively Coupled Plasmas with and without the Presence of an Easily Ionized Element , 1977 .

[32]  P. Boumans,et al.  Studies of a radio frequency inductively coupled argon plasma for optical emission spectrometry—III. Interference effects under compromise conditions for simultaneous multi-element analysis☆ , 1976 .

[33]  D. J. Kalnicky,et al.  Inductively coupled plasma-optical emission spectroscopy: Excitation temperatures experienced by analyte species , 1975 .

[34]  G. R. Kornblum,et al.  Arrangement for measuring spatial distributions in an argon induction coupled RF plasma , 1974 .

[35]  J. F. Alder,et al.  A spectroscopic study of some radio frequency mixed gas plasmas , 1973 .

[36]  W. L. Jolly,et al.  The Hydrolysis of Aqueous Hydroborate , 1962 .