V˙O2max may not be reached during exercise to exhaustion above critical power.

PURPOSE This study was designed to determine whether V˙O(2) reaches a maximum, equivalent to that attained in an incremental exercise test to exhaustion, during "submaximal" fatigue-inducing constant-power exercise bouts above critical power (CP). METHODS Nine males (age = 24.6 ± 3.6 yr, height = 182.8 ± 6.9 cm, weight = 77.8 ± 12.1 kg) and four females (age = 29.0 ± 7.3 yr, height = 170.8 ± 3.2 cm, weight = 61.8 ± 8.2 kg) underwent an incremental V˙O(2max) test (IET) on a cycle ergometer, followed by four or five randomly assigned constant-power exercise bouts to exhaustion, on separate days. The CP for each subject was estimated using linear and nonlinear regression. RESULTS IET V˙O(2max) averaged 3.55 ± 0.92 L·min (RER = 1.21 ± 0.05, HR = 186 ± 10 bpm, 96.1% ± 6.3% of age-predicted maximum). Mean peak V˙O(2) (range = 3.32 ± 0.88 to 3.54 ± 0.91 L·min) during the three highest constant-power bouts (two of which were 53 to 82 W less than peak power output attained during IET) was not significantly different from IET V˙O(2max). Eleven of 13 subjects exceeded their IET V˙O(2max) during at least one of the constant-power exercise bouts. However, peak V˙O(2) (3.11 ± 0.79 L·min) during the lowest constant-power exercise bout, which ranged from 10 to 36 W above CP estimated with a two-parameter nonlinear model, was significantly lower than IET V˙O(2max) (88.2% ± 9.4% of IET V˙O(2max)). CONCLUSIONS At power outputs above CP, V˙O(2) does not necessarily increase to maximum during constant-power exercise to exhaustion. In addition, the highest V˙O(2) values measured during a traditional V˙O(2) "max" test (i.e., IET) may not reflect the highest attainable V˙O(2) despite V˙O(2max) criteria being met.

[1]  Anni Vanhatalo,et al.  Muscle fiber recruitment and the slow component of O2 uptake: constant work rate vs. all-out sprint exercise. , 2011, American journal of physiology. Regulatory, integrative and comparative physiology.

[2]  D. Poole,et al.  Critical speed in the rat: implications for hindlimb muscle blood flow distribution and fibre recruitment , 2010, The Journal of physiology.

[3]  Anni Vanhatalo,et al.  Critical power: implications for determination of V˙O2max and exercise tolerance. , 2010, Medicine & Science in Sports & Exercise.

[4]  S. Carroll,et al.  Emergence of the verification phase procedure for confirming ‘true’V̇O2max , 2009, Scandinavian journal of medicine & science in sports.

[5]  Sharon R. Rana,et al.  Physiological responses at five estimates of critical velocity , 2008, European Journal of Applied Physiology.

[6]  David C. Poole,et al.  Validity of criteria for establishing maximal O2 uptake during ramp exercise tests , 2008, European Journal of Applied Physiology.

[7]  Jonathan Fulford,et al.  Muscle metabolic responses to exercise above and below the "critical power" assessed using 31P-MRS. , 2008, American journal of physiology. Regulatory, integrative and comparative physiology.

[8]  Anni Vanhatalo,et al.  Determination of critical power using a 3-min all-out cycling test. , 2007, Medicine and science in sports and exercise.

[9]  T. Barstow,et al.  Effect of work rate on the functional ‘gain’ of Phase II pulmonary O2 uptake response to exercise , 2004, Respiratory Physiology & Neurobiology.

[10]  B. Whipp,et al.  The maximally attainable VO2 during exercise in humans: the peak vs. maximum issue. , 2003, Journal of applied physiology.

[11]  Andrew M. Jones,et al.  Maximal lactate steady state, critical power and EMG during cycling , 2002, European Journal of Applied Physiology.

[12]  C. Willíams,et al.  Physiological responses during exercise to exhaustion at critical power , 2002, European Journal of Applied Physiology.

[13]  David W Hill,et al.  The relationship between power and the time to achieve .VO(2max). , 2002, Medicine and science in sports and exercise.

[14]  J. Doust,et al.  Oxygen uptake kinetics during treadmill running across exercise intensity domains , 2002, European Journal of Applied Physiology.

[15]  T. Housh,et al.  The effect of mathematical modeling on critical velocity , 2001, European Journal of Applied Physiology.

[16]  R. Morton,et al.  Maximal endurance time at VO2max. , 2000, Medicine and science in sports and exercise.

[17]  T J Housh,et al.  Effect of mathematical modeling on the estimation of critical power. , 1998, Medicine and science in sports and exercise.

[18]  D. Bishop,et al.  Ramp and constant power trials produce equivalent critical power estimates. , 1997, Medicine and science in sports and exercise.

[19]  G. Gaesser,et al.  Assessment of the aerosport TEEM 100 portable metabolic measurement system. , 1996, Medicine and science in sports and exercise.

[20]  Morton Rh,et al.  A 3-parameter critical power model , 1996 .

[21]  G. Gaesser,et al.  The validity of regulating blood lactate concentration during running by ratings of perceived exertion. , 1996, Medicine and science in sports and exercise.

[22]  D. Poole,et al.  The Slow Component of Oxygen Uptake Kinetics in Humans , 1996, Exercise and sport sciences reviews.

[23]  A Garfinkel,et al.  Estimation of critical power with nonlinear and linear models. , 1995, Medicine and science in sports and exercise.

[24]  E. Howley,et al.  Criteria for maximal oxygen uptake: review and commentary. , 1995, Medicine and science in sports and exercise.

[25]  V. Billat,et al.  Times to exhaustion at 90, 100 and 105% of velocity at VO2 max (maximal aerobic speed) and critical speed in elite long-distance runners. , 1995, Archives of physiology and biochemistry.

[26]  David W. Hill,et al.  The Critical Power Concept , 1993, Sports medicine.

[27]  B. Quigley,et al.  Endurance training enhances critical power. , 1992, Medicine and science in sports and exercise.

[28]  T M McLellan,et al.  A comparative evaluation of the individual anaerobic threshold and the critical power. , 1992, Medicine and science in sports and exercise.

[29]  T J Housh,et al.  The Accuracy of the Critical Velocity Test for Predicting Time to Exhaustion during Treadmill Running , 1992, International journal of sports medicine.

[30]  T. Housh,et al.  Physiological Responses at the Fatigue Threshold , 1991, International journal of sports medicine.

[31]  G. Gaesser,et al.  Effects of pedaling speed on the power-duration relationship for high-intensity exercise. , 1991, Medicine and science in sports and exercise.

[32]  Brian M. Quigley,et al.  Blood lactate in trained cyclists during cycle ergometry at critical power , 1990, European Journal of Applied Physiology and Occupational Physiology.

[33]  Terry J. Housh,et al.  The accuracy of the critical power test for predicting time to exhaustion during cycle ergometry , 1989 .

[34]  S A Ward,et al.  Metabolic and respiratory profile of the upper limit for prolonged exercise in man. , 1988, Ergonomics.

[35]  A. Amery,et al.  Ventilatory thresholds during short- and long-term exercise. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[36]  S. Ward,et al.  The effects of training on the metabolic and respiratory profile of high-intensity cycle ergometer exercise , 2006, European Journal of Applied Physiology and Occupational Physiology.

[37]  D. Cunningham,et al.  Physiological responses of young and elderly men to prolonged exercise at critical power , 2004, European Journal of Applied Physiology and Occupational Physiology.

[38]  D. W. Hill,et al.  A physiological description of critical velocity , 1999, European Journal of Applied Physiology and Occupational Physiology.

[39]  K. Cureton,et al.  Effect of the slow-component rise in oxygen uptake on VO2max. , 1996, Medicine and science in sports and exercise.