An alternative practical design method for structures with viscoelastic dampers

Viscoelastic dampers (VEDs) are one of the most common passive control devices used in new and retrofit building projects which reduce the structure responses and dissipate seismic energy during an earthquake. Various methods to design this kind of dampers have been proposed based on the desired level of additional damping, eigenvalue assignment, modal strain energy, linear quadratic regulator control theories, and other approaches. In the current engineering practice, the popular method is the one based on the modal strain energy that uses the inter-story lateral stiffness as one of the main variables for damper design. However, depending on the configuration of the structure, in some cases the resulting interstory lateral stiffness can be very large. Consequently, the dampers size would also be large producing much more damping than that effectively necessary, resulting in an increase of the overall cost of the supplemental damping system and causing excessive stress on the structural elements connected to the dampers. In this paper an alternative practical design method for structures with VEDs is proposed. This method uses the inter-story shear forces as one of the main variables to accomplish the damper design compared to what was done in previous studies. Nonlinear time-history analyses were conducted on a 7-story reinforced concrete (RC) structure to check the reliability and effectiveness of the proposed method. Comparisons on the seismic performance between the structure without dampers and that equipped with VEDs were carried out. It is concluded that the proposed method results in a very suitable size of dampers, which are able to improve the performance of the structure at all levels of earthquake ground motions and satisfying the drift requirement prescribed in the codes.

[1]  Ting-Hua Yi,et al.  Multi-stage structural damage diagnosis method based on "energy-damage" theory , 2013 .

[2]  T. T. Soong,et al.  Seismic Design of Viscoelastic Dampers for Structural Applications , 1992 .

[3]  Linsheng Huo,et al.  Advances in Structural Control in Civil Engineering in China , 2010 .

[4]  Hong-Nan Li,et al.  Study on Optimal Placement and Reasonable Number of Viscoelastic Dampers by Improved Weight Coefficient Method , 2013 .

[5]  Seyed Mehdi Zahrai,et al.  Iterative step-by-step procedure for optimal placement and design of viscoelastic dampers to improve damping ratio , 2017 .

[6]  Ruifu Zhang,et al.  A practical design method for reinforced concrete structures with viscous dampers , 2012 .

[7]  Jinkoo Kim,et al.  Optimal design of viscoelastic dampers using eigenvalue assignment , 2004 .

[8]  Gangbing Song,et al.  Recentering Shape Memory Alloy Passive Damper for Structural Vibration Control , 2013 .

[9]  James M. Ricles,et al.  Simplified design procedure for frame buildings with viscoelastic or elastomeric structural dampers , 2005 .

[10]  Gang Li,et al.  Experimental study of structure with dual function metallic dampers , 2007 .

[11]  J. N. Yang,et al.  Design of Passive Energy Dissipation Systems Based on LQR Control Methods , 1999 .

[12]  Anita Shukla,et al.  Optimal Use of Viscoelastic Dampers in Building Frames for Seismic Force , 1999 .

[13]  Shunming Gong,et al.  Seismic analysis for tall and irregular temple buildings: A case study of strong nonlinear viscoelastic dampers , 2017 .

[14]  Andrei M. Reinhorn,et al.  Design of Supplemental Dampers for Control of Structures , 1996 .

[15]  T. T. Soong,et al.  Passive Energy Dissipation Systems in Structural Engineering , 1997 .

[16]  Zhidong Yang,et al.  Dynamic responses of two buildings connected by viscoelastic dampers under bidirectional earthquake excitations , 2014, Earthquake Engineering and Engineering Vibration.

[17]  Linzhang Lu,et al.  A Gradient Based Iterative Solutions for Sylvester Tensor Equations , 2013 .

[18]  Shunming Gong,et al.  Experimental study and numerical simulation on a new type of viscoelastic damper with strong nonlinear characteristics , 2017 .

[19]  Mahendra P. Singh,et al.  Seismic analysis of structures with a fractional derivative model of viscoelastic dampers , 2002 .

[20]  T. T. Soong,et al.  Seismic Behavior and Design Guidelines for Steel Frame Structures with Added Viscoelastic Dampers , 1993 .

[21]  T. T. Soong,et al.  Seismic behaviour of reinforced concrete frame with added viscoelastic dampers , 1995 .

[22]  Jinkoo Kim,et al.  Displacement-Based Design of Supplemental Dampers for Seismic Retrofit of a Framed Structure , 2006 .

[23]  Xilin Lu,et al.  Study on Similarity of Hysteretic Loops and Characteristic Parameters of Viscoelastic Dampers with Test Verifications , 2013 .

[24]  Hong-Nan Li,et al.  Reduction of seismic forces on existing buildings with newly constructed additional stories including friction layer and dampers , 2004 .

[25]  Y. Ribakov,et al.  A method for design of seismic resistant structures with viscoelastic dampers , 2011 .

[26]  Jinkoo Kim,et al.  Efficient siesmic analysis of building structures with added viscoelastic dampers , 2002 .

[27]  T. T. Soong Review of Principles of Passive Supplemental Damping and Seismic Isolation by C. Christopoulos and A. Filiatrault , 2007 .

[28]  Ting-Hua Yi,et al.  Evaluation of earthquake-induced structural damages by wavelet transform , 2009 .