Maximum-likelihood estimation applied to electron microscopic autoradiography

A new method for analysis of electron microscope autoradiographs is described which is based on the maximum-likelihood method of statistics for estimating the intensities of radioactivity in organelle structures. We adopted a Poisson statistical model to describe the autoradiographic grain distributions that we prove results from the underlying Poisson nature of the radioactive decays as well as the additive errors introduced during the formation of grains. Within the model, an interative procedure derived from the expectation-maximization algorithm of mathematical statistics is used to generate the maximum-likelihood estimates. The algorithm has the properties that at every stage of the iteration process the likelihood of the data increases; and for all initial nonzero starting points the algorithm converges to the maximum-likelihood estimates of the organelle intensities. The maximum-likelihood approach differs from the mask-analysis method, and other published quantitative algorithms in the following ways: (1) In deriving estimates of the radioactivity intensities the maximum-likelihood algorithm requires that we obtain the actual locations of the grains as well as the micrograph geometries; each micrograph is digitized so that both the grain locations as well as the geometries of the organelle structures can be used. (2) The maximum-likelihood algorithm iteratively computes the minimum-meansquared-error estimate of the underlying emission locations that resulted in the observed grain distributions, from which intensity estimates are generated; this algorithm does not minimize a chi-squared error statistic. (3) The maximum-likelihood approach is based on a Poisson model and is therefore valid for low-count experiments; there are no minimum constraints on data collection for any single organelle compartment. (4) The maximum-likelihood algorithm requires the form of the point-spread function describing the emission spread; a probability matrix based on the use of overlay masks is not required. (5) The maximum-likelihood algorithm does not change for different organelle geometries; arbitrary geometries are incorporated by maximizing the likelihood-function subject to the geometry constraints. We have performed a preliminary evaluation of the quantitative accuracy of the maximum-likelihood and mask-analysis algorithms. Based on two different phantoms in which we compared the squared error resulting from the two algorithms, we find that the new maximum-likelihood approach provides substantially improved estimates of the radioactivity intensities of the phantoms.

[1]  R. D. Evans,et al.  Atomic Nucleus , 2020, Definitions.

[2]  J. Liquier-Milward Electron Microscopy and Radioautography as Coupled Techniques in Tracer Experiments , 1956, Nature.

[3]  Norman T. J. Bailey,et al.  Statistical Methods in Biology , 1959 .

[4]  L. Caro,et al.  HIGH-RESOLUTION AUTORADIOGRAPHY : I. Methods , 1962 .

[5]  L. Caro HIGH-RESOLUTION AUTORADIOGAPHY : II. The Problem of Resolution , 1962 .

[6]  S. R. Pelc THEORY OF ELECTRON AUTORADIOGRAPHY , 1963 .

[7]  P. Granboulan RESOLVING POWER AND SENSITIVITY OF A NEW EMULSION IN ELECTRON MICROSCOPE AUTORADIOGRAPHY , 1963 .

[8]  R. Ross,et al.  WOUND HEALING AND COLLAGEN FORMATION : V. Quantitative Electron Microscope Radioautographic Observations of Proline-H3 Utilization by Fibroblasts , 1965 .

[9]  M. Salpeter,et al.  AUTORADIOGRAPHY WITH THE ELECTRON MICROSCOPE; A QUANTITATIVE EVALUATION. , 1965, Laboratory investigation; a journal of technical methods and pathology.

[10]  M. Salpeter H3‐proline incorporation into cartilage: Electron microscope autoradiographic observations , 1968, Journal of morphology.

[11]  M. Salpeter,et al.  RESOLUTION IN ELECTRON MICROSCOPE RADIOAUTOGRAPHY , 1969, The Journal of cell biology.

[12]  M. Salpeter,et al.  THE DISTRIBUTION OF LABELED NOREPINEPHRINE WITHIN SYMPATHETIC NERVE TERMINALS STUDIED WITH ELECTRON MICROSCOPE RADIOAUTOGRAPHY , 1969, The Journal of cell biology.

[13]  Nadler Nj The interpretation of grain counts in electron microscope radioautography. , 1971 .

[14]  M. Salpeter,et al.  RESOLUTION IN ELECTRON MICROSCOPE RADIOAUTOGRAPHY , 1971, The Journal of cell biology.

[15]  N. Blackett,et al.  A NEW METHOD FOR ANALYZING ELECTRON MICROSCOPE AUTORADIOGRAPHS USING HYPOTHETICAL GRAIN DISTRIBUTIONS , 1973, The Journal of cell biology.

[16]  Donald L. Snyder,et al.  Random point processes , 1975 .

[17]  N. Blackett,et al.  Analysis of electron microscope autoradiographs using the hypothetical grain analysis method , 1976, Journal of microscopy.

[18]  M. Salpeter,et al.  Resolution in electron microscope autoradiography. III. Iodine-125, the effect of heavy metal staining, and a reassessment of critical parameters , 1977, The Journal of cell biology.

[19]  N. Blackett,et al.  A simplified method of "hypothetical grain" analysis of electron microscope autoradiographs. , 1977, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[20]  M. Salpeter,et al.  Resolution of electron microscope autoradiography. IV. Application to analysis of autoradiographs , 1978, The Journal of cell biology.

[21]  M. Salpeter,et al.  High resolution analysis of the secretory pathway in mammotrophs of the rat anterior pituitary , 1981, The Journal of cell biology.

[22]  L. J. Thomas,et al.  A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements , 1981, IEEE Transactions on Nuclear Science.

[23]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[24]  Donald L. Snyder,et al.  Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight Measurements , 1983, IEEE Transactions on Nuclear Science.

[25]  D. Snyder Utilizing Side Information in Emission Tomography , 1984, IEEE Transactions on Nuclear Science.

[26]  M. Salpeter,et al.  Acetylcholine receptor at neuromuscular junctions by EM autoradiography using mask analysis and linear sources , 1984 .

[27]  P. Corr,et al.  Pathophysiologic concentrations of lysophosphoglycerides quantified by electron microscopic autoradiography. , 1984, Laboratory investigation; a journal of technical methods and pathology.