Ultraperformance liquid chromatography-tandem mass spectrometry assay for iohexol in human serum.

BACKGROUND Iohexol is an iodinated contrast dye that has been shown to be useful in the estimation of glomerular filtration rate (GFR) in patients with suspected renal insufficiency. We developed and validated an ultraperformance liquid chromatography (UPLC)-triple quadrupole mass spectrometry (MS/MS) assay for quantifying iohexol in human serum. METHODS Sample preparation involved dilution of 50 microL serum with 400 microL water, followed by protein precipitation with zinc sulfate and methanol containing the structural analog ioversol as the internal standard. After 1:20 dilution of the supernatant with water, 5 microL was injected into the UPLC-MS/MS system. Chromatography was performed using a Waters Oasis HLB 5-microm particle size, 2.1 x 20 mm column maintained at 50 degrees C. We used a 1-step acetonitrile/0.1% formic acid gradient to elute the compounds of interest at a common retention time of 0.96 min. The multiple reaction monitoring transitions used for integration and quantification were m/z 821.7-->803.7 for iohexol and m/z 807.9-->589.0 for ioversol in the electrospray positive ionization mode. RESULTS The assay was linear from 2.5 mg/L (lower limit of quantification) to 1500 mg/L iohexol, with a mean extraction efficiency of >99%. Recovery of nominal target concentrations was 99%-102%. Interassay imprecision ranged from 7.9% at a concentration of 2.5 mg/L to 4.1% at 1000 mg/L. Ion suppression studies showed no matrix effects on the ionization of the 2 compounds. CONCLUSIONS This rapid UPLC-MS/MS method can be successfully used for quantifying iohexol in human serum.

[1]  S. Groleau,et al.  Development and evaluation of a liquid chromatography-mass spectrometry assay and its application for the assessment of renal function. , 2008, Journal of chromatography. A.

[2]  G. Schwartz,et al.  Estimating and measuring glomerular filtration rate in children , 2008, Current opinion in nephrology and hypertension.

[3]  T. Spillmann,et al.  SPE for Endo- and Exo-Iohexol Analysis with HPLC in Canine Serum and Rat Urine , 2007 .

[4]  Soo-Youn Lee,et al.  Determination of iohexol clearance by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  C. Castells,et al.  Effect of sample solvent on the chromatographic peak shape of analytes eluted under reversed-phase liquid chromatogaphic conditions. , 2006, Journal of chromatography. A.

[6]  S. Cole,et al.  Glomerular filtration rate via plasma iohexol disappearance: pilot study for chronic kidney disease in children. , 2006, Kidney international.

[7]  D. Sica,et al.  Simple HPLC-UV method for determination of iohexol, iothalamate, p-aminohippuric acid and n-acetyl-p-aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[8]  P. Taylor Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry. , 2005, Clinical biochemistry.

[9]  F. Akhlaghi,et al.  Development and validation of an HPLC-UV method for determination of iohexol in human plasma. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[10]  T. Annesley,et al.  Simple extraction protocol for analysis of immunosuppressant drugs in whole blood. , 2004, Clinical chemistry.

[11]  M. Giorgi,et al.  A new HPLC method to determine glomerular filtration rate and effective renal plasma flow in conscious dogs by single intravenous administration of iohexol and p-aminohippuric acid. , 2004, Journal of chromatographic science.

[12]  T. Kitahashi,et al.  Method development for determining the iohexol in human serum by micellar electrokinetic capillary chromatography. , 2004, Journal of pharmaceutical and biomedical analysis.

[13]  T. Annesley Ion suppression in mass spectrometry. , 2003, Clinical chemistry.

[14]  B. Matuszewski,et al.  Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.

[15]  J. Layne,et al.  Volume-load capacity in fast-gradient liquid chromatography effect of sample solvent composition and injection volume on chromatographic performance. , 2001, Journal of chromatography. A.

[16]  Vinod P. Shah,et al.  Bioanalytical Method Validation—A Revisit with a Decade of Progress , 2000, Pharmaceutical Research.

[17]  T. Greibrokk,et al.  Temperature effects on packed-capillary liquid chromatography of the X-ray contrast agent iodixanol. , 2000, Journal of chromatographic science.

[18]  W. Braselton,et al.  Measurement of serum iohexol by determination of iodine with inductively coupled plasma-atomic emission spectroscopy. , 1997, Clinical chemistry.

[19]  N. Perico,et al.  Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. , 1995, Journal of the American Society of Nephrology : JASN.

[20]  R. Majors,et al.  Phase collapse in reversed-phase liquid chromatography , 2002 .

[21]  J. Bröchner-Mortensen A simple method for the determination of glomerular filtration rate. , 1972, Scandinavian journal of clinical and laboratory investigation.