Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography.

Studies investigating normal and abnormal cardiac development are frequently limited by an inability to assess cardiovascular function within the intact organism. In this work, optical coherence tomography (OCT), a new method of micron-scale, noninvasive imaging based on the measurement of backscattered infrared light, was introduced for the high resolution assessment of structure and function in the developing Xenopus laevis cardiovascular system. Microstructural details, such as ventricular size and wall positions, were delineated with OCT at 16-microm resolution and correlated with histology. Three-dimensional representation of the cardiovascular system also was achieved by repeated cross-sectional imaging at intervals of 25 microm. In addition to structural information, OCT provides high speed in vivo axial ranging and imaging, allowing quantitative dynamic activity, such as ventricular ejection fraction, to be assessed. The sensitivity of OCT for dynamic assessment was demonstrated with an inotropic agent that altered cardiac function and dimensions. Optical coherence tomography is an attractive new technology for assessing cardiovascular development because of its high resolution, its ability to image through nontransparent structures, and its inexpensive portable design. In vivo and in vitro imaging are performed at a resolution approaching that of histopathology without the need for animal killing.

[1]  C. Walker Ophthalmology , 1859, Bristol medico-chirurgical journal.

[2]  Kurt E. Johnson,et al.  Normal Table of Xenopus Laevis , 1968, The Yale Journal of Biology and Medicine.

[3]  J. Sedat,et al.  Fluorescence microscopy: reduced photobleaching of rhodamine and fluorescein protein conjugates by n-propyl gallate. , 1982, Science.

[4]  D M Shotton,et al.  Video-enhanced light microscopy and its applications in cell biology. , 1988, Journal of cell science.

[5]  N. Reichek,et al.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[6]  G. V. Van Hare,et al.  Two-dimensional echocardiographic determination of ventricular volumes in the fetal heart. Validation studies in fetal lambs. , 1990, Circulation.

[7]  C. Archer,et al.  Dermatology , 1906, The Lancet.

[8]  M. Capecchi,et al.  Regionally restricted developmental defects resulting from targeted disruption of the mouse homeobox gene hox-1.5 , 1991, Nature.

[9]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[10]  R. P. Novak,et al.  High-resolution reflectometry in biological tissues. , 1992, Optics letters.

[11]  V. Centonze,et al.  Confocal microscopy of fertilization-induced calcium dynamics in sea urchin eggs. , 1992, Developmental biology.

[12]  D. Clapham,et al.  Acceleration of intracellular calcium waves in Xenopus oocytes by calcium influx. , 1993, Science.

[13]  W J Stewart,et al.  Left ventricular volume calculation with integrated backscatter from echocardiography. , 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[14]  R E Jacobs,et al.  Magnetic resonance microscopy of embryonic cell lineages and movements. , 1994, Science.

[15]  J. Fujimoto,et al.  Determination of the refractive index of highly scattering human tissue by optical coherence tomography. , 1995, Optics letters.

[16]  J. Fujimoto,et al.  Optical biopsy and imaging using optical coherence tomography , 1995, Nature Medicine.

[17]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[18]  J. Nelson,et al.  Characterization of fluid flow velocity by optical Doppler tomography. , 1995, Optics letters.

[19]  James G. Fujimoto,et al.  Optical Coherence Tomography of Ocular Diseases , 1995 .

[20]  J M Schmitt,et al.  Subsurface imaging of living skin with optical coherence microscopy. , 1995, Dermatology.

[21]  J G Fujimoto,et al.  High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al(2)O(3) laser source. , 1995, Optics letters.

[22]  A. Joyner,et al.  Ultrasound backscatter microscope analysis of early mouse embryonic brain development. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[23]  J. Duker,et al.  Imaging of macular diseases with optical coherence tomography. , 1995, Ophthalmology.

[24]  Wolfgang Driever,et al.  gridlock, a localized heritable vascular patterning defect in the zebrafish , 1995, Nature Medicine.

[25]  B. Golubovic,et al.  Single mode fiber-optic catheter/endoscope for optical coherence tomography , 1996, Summaries of papers presented at the Conference on Lasers and Electro-Optics.

[26]  Stephen A. Boppart,et al.  Imaging developing neural morphology using optical coherence tomography , 1996, Journal of Neuroscience Methods.

[27]  B E Bouma,et al.  Rapid acquisition of in vivo biological images by use of optical coherence tomography. , 1996, Optics letters.

[28]  J. Fujimoto,et al.  Investigation of developing embryonic morphology using optical coherence tomography. , 1996, Developmental biology.

[29]  J. Fujimoto,et al.  Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology. , 1996, Circulation.