Use of Composite Arterial and Venous Grafts in Microsurgical Breast Reconstruction: Technical Challenges and Lessons Learned

Summary: The success of microvascular reconstruction depends on many factors. Although many factors cannot be dictated by a surgeon, the success of anastomosis can be maximized by honing skill with performing anastomoses. However, size discrepancy of vessels remains a common challenge, given the lack of an ideal technique. In this study, the authors introduce their experience in using composite deep inferior epigastric arterial and venous grafts to overcome the vessel size and pedicle length discrepancy in lateral thigh and superficial inferior epigastric artery (SIEA) flaps. Of the 1095 flaps performed, the authors identified a total of 12 flaps (one lateral thigh flap and 11 SIEA flaps) on nine patients for breast reconstruction. The authors used deep inferior epigastric vessels to act as interposition grafts between the internal mammary artery and flap pedicle. For the SIEA flaps, the authors anastomosed the SIEA system to the deep inferior epigastric arterial system, checked the viability of the flap, and then transferred the flap to the internal mammary artery and flap pedicle. For the SIEA flaps, the authors anastomosed the SIEA system to the deep inferior epigastric arterial system, checked the viability of the flap, and then transferred the flap to the internal mammary artery system in three patients. In the last five patients, the authors anastomosed the deep inferior epigastric vessels to the internal mammary artery system first, and then transferred the SIEA flap. For the lateral thigh flap, the authors anastomosed grafts to the internal mammary artery system first as well. There were no flap losses or fat necrosis. Although the authors’ outcomes are limited to only breast reconstruction, they believe this method could be expanded to different types of reconstruction, especially reconstruction of the head and neck.

[1]  P. Blondeel,et al.  The Lumbar Artery Perforator Flap in Autologous Breast Reconstruction: Initial Experience with 100 Cases , 2018, Plastic and reconstructive surgery.

[2]  J. Serletti,et al.  Superficial Inferior Epigastric Artery: Learning Curve versus Reality , 2016, Plastic and reconstructive surgery.

[3]  M. Walsh,et al.  The influence of the instabilities in modelling arteriovenous junction haemodynamics. , 2015, Journal of biomechanics.

[4]  P. Blondeel,et al.  Early experience with the free lumbar artery perforator flap for breast reconstruction. , 2015, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[5]  C. Coroneos,et al.  SIEA versus DIEP Arterial Complications: A Cohort Study , 2015, Plastic and reconstructive surgery.

[6]  Susumu Tamai,et al.  History of Microsurgery , 2009, Plastic and reconstructive surgery.

[7]  A. Spiegel,et al.  An Intraoperative Algorithm for Use of the SIEA Flap for Breast Reconstruction , 2007, Plastic and reconstructive surgery.

[8]  J. de la Peña‐Salcedo,et al.  Techniques for management of size discrepancies in microvascular anastomosis , 2000, Microsurgery.

[9]  V T Turitto,et al.  Mechanical factors affecting hemostasis and thrombosis. , 1998, Thrombosis research.

[10]  J. Tarbell,et al.  Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis. , 1996, Journal of biomechanics.

[11]  M. Portmann [History of microsurgery]. , 1996, Revue de laryngologie - otologie - rhinologie.

[12]  Z. Xiu,et al.  A new technique to anastomose vessels with great discrepancy in diameter. , 1993, British journal of plastic surgery.

[13]  D. Lyman,et al.  Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow. , 1992, Journal of biomechanics.

[14]  K. Hayashi,et al.  Flow visualization analysis in a model of artery-graft anastomosis. , 1992, Bio-medical materials and engineering.

[15]  J. Grotting The free abdominoplasty flap for immediate breast reconstruction. , 1991, Annals of plastic surgery.

[16]  G. I. Taylor,et al.  The vascular territories (angiosomes) of the body: experimental study and clinical applications. , 1987, British journal of plastic surgery.

[17]  J. Albertengo,et al.  A comparative study of flap survival rates in end-to-end and end-to-side microvascular anastomosis. , 1981, Plastic and reconstructive surgery.

[18]  R. Daniel,et al.  Preferential use of end-to-side arterial anastomoses in free flap transfers. , 1980, Plastic and reconstructive surgery.

[19]  T. Harashina,et al.  Expansion of smaller vessel diameter by fish-mouth incision in microvascular anastomosis with marked size discrepancy. , 1980, Plastic and reconstructive surgery.

[20]  R C Troutman,et al.  The operating microscope in ophthalmic surgery. , 1965, Transactions of the American Ophthalmological Society.

[21]  Jacobs Jh,et al.  Microsurgery in anastomosis of small vessels. , 1960 .

[22]  J. McLean THE THROMBOPLASTIC ACTION OF CEPHALIN , 1916 .