Signal processing in urodynamics: towards high definition urethral pressure profilometry

BackgroundUrethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs.MethodsWe use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra’s inside. Finally, the pressure distribution on the urethra’s outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF’s frequency response to determine the relevant frequency band for pressure information on the urinary sphincter.ResultsExperimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra’s outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location.ConclusionsWith its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with detailed information on the pressure distribution in and around the urethra. Therefore, HD-UPP overcomes many current limitations of conventional UPP and offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct anatomical location. This could enable the development of focal therapy approaches in the treatment of SUI.

[1]  Frédo Durand,et al.  Image and depth from a conventional camera with a coded aperture , 2007, SIGGRAPH 2007.

[2]  D. Griffiths,et al.  The pressure within a collapsed tube, with special reference to urethral pressure. , 1985, Physics in medicine and biology.

[3]  Oliver Sawodny,et al.  Sampling lattice and signal reconstruction in urodynamics , 2014, 2014 12th International Conference on Signal Processing (ICSP).

[4]  T. Kessler,et al.  Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: a prospective, single-blind, randomized trial. , 2008, The Journal of urology.

[5]  James S Walter,et al.  A Balloon-Tipped Catheter for Measuring Urethral Pressures , 2009, The journal of spinal cord medicine.

[6]  E. Versi,et al.  Discriminant analysis of urethral pressure profilometry data for the diagnosis of genuine stress incontinence , 1990, British journal of obstetrics and gynaecology.

[7]  Paul L. Butzer,et al.  Two-dimensional nonuniform sampling expansions an iterative approach. i. theory of two-dimensional bandlimited signals , 1989 .

[8]  T. Strohmer,et al.  Fast scattered data approximation with Neumann and other boundary conditions , 2004 .

[9]  D. Griffiths,et al.  Standardisation of urethral pressure measurement: Report from the standardisation sub‐committee of the International Continence Society , 2002, Neurourology and urodynamics.

[10]  Jason T. Connor,et al.  Air-charged and microtransducer urodynamic catheters in the evaluation of urethral function , 2004, International Urogynecology Journal.

[11]  Linda Cardozo,et al.  Textbook of Female Urology and Urogynecology , 2001 .

[12]  R. Yang Tactile Perception for Multifingered Hands , 1987 .

[13]  A. Rossier,et al.  5-microtransducer catheter in evaluation of neurogenic bladder function. , 1986, Urology.

[14]  Oliver Sawodny,et al.  High definition urethral pressure profilometry: Evaluating a novel microtip catheter , 2016, Neurourology and urodynamics.

[15]  Anat Levin Deconvolution using natural image priors-Lecture notes , 2010 .

[16]  Paul L. Butzer,et al.  Two-dimensional nonuniform sampling expansions an iterative approach. ii. reconstruction formulae and applications , 1989 .

[17]  Hans Stødkilde-Jørgensen,et al.  Continuous recording of urethral activity in healthy female volunteers , 1986 .

[18]  Oliver Sawodny,et al.  Towards a Treatment of Stress Urinary Incontinence: Application of Mesenchymal Stromal Cells for Regeneration of the Sphincter Muscle , 2014, Journal of clinical medicine.

[19]  Per Ask,et al.  Pressure measurement techniques in urodynamic investigations , 1990 .

[20]  Marcus J. Drake,et al.  Textbook of Female Urology and Urogynecology , 2010 .

[21]  G. Bartsch,et al.  Anatomic and functional studies of the male and female urethral sphincter , 2000, World Journal of Urology.

[22]  G. Enhorning,et al.  Simultaneous recording of intravesical and intra-urethral pressure. A study on urethral closure in normal and stress incontinent women. , 1961, Acta chirurgica Scandinavica. Supplementum.

[23]  G Bartsch,et al.  The female urethral sphincter: a morphological and topographical study. , 1998, The Journal of urology.

[24]  L. Baskin,et al.  An anatomical description of the male and female urethral sphincter complex. , 2004, The Journal of urology.

[25]  Peter K. Sand,et al.  Comparison of Microtransducer and Fiberoptic Catheters for Urodynamic Studies , 2001, Obstetrics and gynecology.

[26]  Oliver Sawodny,et al.  Using deconvolution to determine the sphincter strength distribution around the urethra , 2015, 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings.

[27]  Hans Colstrup,et al.  Pressure variations in the female urethra measured by the infusion technique: Is it an artifact? , 1988 .

[28]  Yonina C. Eldar,et al.  FILTERBANK RECONSTRUCTION OF PERIODIC SIGNALS AND SAMPLING IN POLAR COORDINATES , 2003 .

[29]  Oliver Sawodny,et al.  Eliminating pulse-induced artifacts in Urethral Pressure data , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[30]  Fredrik Gustafsson,et al.  Determining the initial states in forward-backward filtering , 1996, IEEE Trans. Signal Process..