Delivery of Gaseous Microemboli With Vacuum-Assisted Venous Drainage During Pulsatile and Nonpulsatile Perfusion in a Simulated Neonatal Cardiopulmonary Bypass Model

This study investigated delivery of gaseous microemboli (GME) with vacuum-assisted venous drainage (VAVD) at various flow rates and perfusion modes in a simgr;lated neonatal cardiopulmonary bypass (CPB) model. Four transducers (postpump, postoxygenator, postfilter, and venous line) of the emboli detection and classification (EDAC) quantifier were inserted into the CPB circuit to detect and classify GME. Four negative pressures (0, −15, −30, and −45 mm Hg), 3 flow rates (750, 1,000, and 1,250 ml/min), and 2 perfusion modes (pulsatile and nonpulsatile) were tested. After injecting 10 ml air into the venous line via an 18G needle, 2-minute segments of data were recorded simgr;ltaneously through 4 transducers. This entire process was repeated 6 times for each unique combination of pressure, flow rate, and perfusion mode, yielding a total of 144 experiments. Independent of perfusion mode and flow rate, the use of VAVD with higher negative pressures delivered significantly more GME at the postpump site. There was no difference in delivery at the postfilter site. The majority of GME were trapped by the Capiox Baby-RX hollow-fiber membrane oxygenator. Compared with nonpulsatile flow, pulsatile flow transferred more GME at the postpump site at all 3 flow rates. Our results suggest that VAVD with higher negative pressures, increased flow rates, and pulsatile flow could deliver more GME at the postpump site when a fixed volume air is introduced into the venous line. The Emboli Detection and Classification Quantifier is a sensitive tool for the detection and classification of GME as small as 10 microns in this simgr;lated neonatal model.

[1]  A. Ündar,et al.  Microemboli Detection and Classification by Innovative Ultrasound Technology During Simulated Neonatal Cardiopulmonary Bypass at Different Flow Rates, Perfusion Modes, and Perfusate Temperatures , 2008, ASAIO journal.

[2]  A. Ündar,et al.  Detection and Classification of Gaseous Microemboli During Pulsatile and Nonpulsatile Perfusion in a Simulated Neonatal CPB Model , 2007, ASAIO journal.

[3]  Johnathan L. Sevick,et al.  Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter. , 2007, Ultrasound in medicine & biology.

[4]  T. Loughin SAS® for Mixed Models, 2nd edition Edited by Littell, R. C., Milliken, G. A., Stroup, W. W., Wolfinger, R. D., and Schabenberger, O. , 2006 .

[5]  O. Alfieri,et al.  Vacuum-assisted venous drainage in extrathoracic cardiopulmonary bypass management during minimally invasive cardiac surgery , 2006, Perfusion.

[6]  F. Rubens,et al.  Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypass. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  Frank Merkle,et al.  Perfusion technique for nonhaemic cardiopulmonary bypass prime in neonates and infants under 6 kg body weight , 2004, Perfusion.

[8]  D. Stump,et al.  Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass? , 2002, The Annals of thoracic surgery.

[9]  B. Keogh,et al.  Cerebrovascular accident after vacuum-assisted venous drainage in a Fontan patient: a cautionary tale. , 2001, Annals of Thoracic Surgery.

[10]  H. Matsuda,et al.  Clinical application of vacuum-assisted cardiopulmonary bypass with a pressure relief valve. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[11]  A. Galloway,et al.  Assisted venous drainage presents the risk of undetected air microembolism. , 2000, The Journal of thoracic and cardiovascular surgery.

[12]  S. Mitchell,et al.  Venous air in the bypass circuit: a source of arterial line emboli exacerbated by vacuum-assisted drainage. , 1999, The Annals of thoracic surgery.

[13]  M. Borger,et al.  Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventions. , 1999, The Annals of thoracic surgery.

[14]  M. Carrier,et al.  Vacuum-assisted venous drainage does not increase the neurological risk. , 2002, The heart surgery forum.